DIODE TVS 24VR 1500W DO-201 5%

LCE24A

Manufacturer Part Number
LCE24A
Description
DIODE TVS 24VR 1500W DO-201 5%
Manufacturer
Littelfuse Inc
Series
LCEr
Datasheet

Specifications of LCE24A

Package / Case
DO-201AA, DO-27, Axial
Voltage - Reverse Standoff (typ)
24V
Voltage - Breakdown
26.7V
Power (watts)
1500W
Polarization
Unidirectional
Mounting Type
Through Hole
Polarity
Unidirectional
Channels
1 Channel
Clamping Voltage
38.9 V
Operating Voltage
24 V
Breakdown Voltage
26.7 V
Termination Style
Through Hole
Peak Surge Current
39 A
Peak Pulse Power Dissipation
1500 W
Capacitance
100 pF
Maximum Operating Temperature
+ 175 C
Minimum Operating Temperature
- 55 C
Dimensions
5.3 mm Dia. x 5.2 (Max) mm W x 9.5 mm L
Lead Free Status / RoHS Status
Lead free by exemption / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free by exemption / RoHS Compliant
Other names
LCE24AT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCE24A
Manufacturer:
VISHAY
Quantity:
30 000
©2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to http://www.Littelfuse.com/series/LCE.html for current information.
Ratings and Characteristic Curves
Figure 1 - Peak Pulse Power Rating
Figure 3 - Pulse Waveform
Figure 5 - Steady State Power Derating Curve
1000
150
100
100
0.1
50
10
6.5
5.5
4.5
3.5
2.5
1.5
0.5
1
0
0.000001
6
5
4
3
2
1
0
0
0
t d
25
t r =10μsec
t
Peak Value
I PPM
T
d
1.0
50
-Pluse Width (Sec.)
L
-Lead Temperature (ºC)
0.00001
75
t-Time (ms)
Half Value
I PPM
2.0
100 125 150 175 200
( )
I PPM
2
10/1000μsec. Waveform
as defined by R.E.A
T J =25°C
Pulse Width(td) is defined
as the point where the peak
current decays to 50% of I PPM
0.0001
(T
A
=25°C unless otherwise noted)
3.0
Transient Voltage Suppression Diodes
Axial Leaded – 1500W > LCE series
0.001
4.0
Revision: January 09, 2009
95
Figure 2 - Power Derating Curve
Figure 4 - AC Line Protection Application
100
75
50
25
0
Application Note: Device must be used
with two units in parrellel, opposite in polarity
as shown on circuit for AC signal lin
protection.
0
25
T
(Single Pulse)
L
Peak Power
50
-Lead Temperature (ºC)
Low Capacitance
+
TVC
75
+
100
Average Power
125
150
175