BUZZER AUDIO MAGNETIC 5VP-P SMD

CT-1205H

Manufacturer Part Number
CT-1205H
Description
BUZZER AUDIO MAGNETIC 5VP-P SMD
Manufacturer
CUI Inc
Series
CTr
Type
Magnetic Transducer, External Driver
Datasheet

Specifications of CT-1205H

Frequency
2.4kHz
Voltage - Rated
5Vo-p
Current Rating
60mA
Size / Dimension
Square - 12.8mm L x 12.8mm W x 10mm H
Mounting Type
Surface Mount
Sound Pressure Level
88dB
Operating Mode
Continuous
Voltage Range
3 ~ 7Vo-p
Termination
Solder Pads
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Frequency
-
Other names
102-1266-2
PART NUMBER:
MECHANICAL CHARACTERISTICS
item
soldering
soldering heat resistance
terminal mechanical strength
vibration test
drop test
ENVIRONMENT TEST
item
high temperature test
low temperature test
thermal shock test
temperature cycle test
20050 SW 112
CT-1205H
th
Ave. Tualatin, Oregon 97062
test condition
Lead terminals are immersed in a solder bath of +270 ±5°C for
3 ±1 seconds.
The product follows the reflow temperature curve to test its reflow
thermo stability.
For 10 seconds, the force of 9.8 N (1.0 kg) is applied to each
terminal in each axial direction.
The buzzer should be measured after a vibration amplitude of 1.5
mm with 10 ~ 55 Hz band of vibration frequency to each of the
3 perpendicular directions for 2 hours.
The buzzer without packaging is subjected to 3 drops on each
axis from the height of 75 cm onto a 40 mm thick wooden board.
test condition
After being placed in a chamber at +85°C for 96 hours.
After being placed in a chamber at -40°C for 96 hours.
The part will be subjected to 10 cycles. One cycle will consist of:
The part will be subjected to 10 cycles. One cycle will consist of:
+85
+25
3hrs
a
DESCRIPTION:
-40
30 min.
12±0.5hrs
b
24hours
60 min.
phone 503.612.2300
3hrs
30 min.
+85
c
MAGNETIC BUZZER
a,b : 90~98%RH
c : 80~98%RH
fax 503.612.2383 www.cui.com
evaluation standard
90% min. of the lead terminals will be
wet with solder.
No interference in operation.
No damage or cutting off
After any tests, the buzzer will meet
specifications without any damage
in appearance and the SPL should be
within ±10% of the initial
measurements.
evaluation standard
After any tests, the buzzer will meet
specifications without any damage in
appearance except SPL. After
4 hours, SPL should be within ±10% of
the initial measurements.
date
page
03/2010
3 of 5