W58-XB1A4A-2 Tyco Electronics, W58-XB1A4A-2 Datasheet

CIRCUIT BREAKER THERM 2A

W58-XB1A4A-2

Manufacturer Part Number
W58-XB1A4A-2
Description
CIRCUIT BREAKER THERM 2A
Manufacturer
Tyco Electronics
Series
W58r
Datasheets

Specifications of W58-XB1A4A-2

Mounting Type
Panel Mount
Breaker Type
Thermal
Voltage
50VDC, 250VAC
Current - Trip (it)
2A
Number Of Poles
1
Actuator Type
Push to Reset
Voltage Rating Vdc
50V
Voltage Rating Vac
250V
Current Rating
2A
No. Of Poles
1
Trip Time@200%
10-45 Sec
Terminals
Quick Tab
Operating Voltage
250V
Product Type
Circuit Breakers
Voltage Rating
250 VoltsAC / 50 VoltsDC
Trip Time
10 s to 45 s
Mounting Style
Through Hole
Termination Style
Quick Connect
Circuit Function
Series trip
Color
White
Dielectric Strength
1.5 KV
Features
Cannot be manually tripped, button extends for visual trip indication
Height
34.93 mm
Illuminated
No
Length
34.93 mm
Product
Thermal Circuit Breakers
Width
16.76 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1-1393249-1
PB194
W58-XB1A4A-2BULK

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W58-XB1A4A-2
Manufacturer:
TE Connectivity
Quantity:
1 926
Agency Approvals
W58 Series is UL 1077 Recognized as Supplementary Protectors, File
E69543, and CSA Accepted as Supplementary Protectors (Appliance
Component Protectors), File LR15734.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 0.5 amp to 30 amp ratings.
• Cannot be manually tripped.
• Button extends for visual trip indication.
• Push button to reset breaker.
• Termination is screw or .250” QC.
Time vs. Current Trip Curve @ +25°C
Electrical Data @ +25°C
Calibration: Breaker will continuously carry 100% of rated load. It may trip
Dielectric Strength: Over 1,500 volts RMS.
Maximum Operating Voltages: 50VDC; 250VAC.
Interrupt Capacity: 2,000 amps at 50VDC (0.5 - 30 amp models).
Resettable Overload Capacity: Ten times rated current.
Dimensions are shown for
reference purposes only.
1000
900
800
700
600
500
400
300
200
100
0
.1
between 101% and 145% of rated load, but must trip at
145% at 25°C.
(A)
1,000 amps at 250VAC (0.5 - 30 amp models).
Note: 30 0amp model not UL or CSA
1
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Time In Seconds
.
10
(A) All 5-30 Amp Models
Overload
1000%
100%
145%
200%
400%
600%
800%
(B)
0.25-0.90 Sec.
0.15-0.65 Sec.
Trip in 1 hour
0.60-1.7 Sec.
1.6-4.5 Sec.
Trip Times
Issued 3-03 (PDF Rev. 1-06)
6.0-30 Sec.
No Trip
Catalog 1308242
100
(B) All 1-4 Amp Models
Overload
1000%
100%
145%
200%
400%
600%
800%
*No UL/CSA
W58
Push To Reset Only
Thermal Circuit Breaker
Maximum Resistance vs. Current Rating @ +25°C
Mechanical/Environmental Data
Shock: Withstands to 10g.
Endurance Cycling: Over 1,000 cycles at 200% of rated load.
Vibration: Withstands to 10g at 10-55 Hz.
Weight: Less than 1 1/2 oz. (42.5g).
Specifications and availability
subject to change.
Trip in 1 hour
3.0-14.0 Sec.
0.75-4.3 Sec.
0.50-3.4 Sec.
1.4-7.0 Sec.
Trip Times
10-45 Sec.
in Amps
Current
Rating
No Trip
0.5
1
2
3
4
5
6
7
1000
series
Resistance
Ambient Compensation Chart
To use this chart: Read up from the ambient
temperature to the curve, and across to find a correction
factor. Multiply the breaker rating by the correction factor
to determine the compensated rating. Calculate the
overloads in terms of the compensated rating to use the
published trip curve.
Maximum
in Ohms
1.40
1.30
1.20
1.10
1.00
0.90
0.80
0.70
0.60
5.0
1.35
0.32
0.18
0.10
0.026
0.026
0.020
Ambient Temperature In Degrees Centigrade (°C)
–20 –10 0
in Amps
Current
Rating
10 20 30 40 50 60
12
15
20
25
30*
10
8
9
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Resistance
Maximum
in Ohms
0.020
0.020
0.014
0.010
0.010
0.005
0.006
0.004
P&B
107

Related parts for W58-XB1A4A-2

W58-XB1A4A-2 Summary of contents

Page 1

... Push button to reset breaker. • Termination is screw or .250” QC. Agency Approvals W58 Series is UL 1077 Recognized as Supplementary Protectors, File E69543, and CSA Accepted as Supplementary Protectors (Appliance Component Protectors), File LR15734. Users should thoroughly review the technical data before selecting a product part number ...

Page 2

... F = White with black rate marking, no trip band 15 = Two hex nuts/lock washer mtg. hardware supplied (Use C, Step # *Not UL or CSA W58-XB1A4A-15 W58-XC4C12A-2 W58-XB1A4A-20 W58-XC4C12A-3 W58-XB1A4A-25 W58-XC4C12A-5 W58-XB1A4A-30 W58-XC4C12A-7 W58-XC4C12A-1 W58-XC4C12A-10 Terminal Options .050 MAX. (1.27) CLOSED POSITION CODES 1 & 4 .312±.005 1 ...

Page 3

Mounting Hardware Disc Hex Nut BLACK ETCHED LETTERS .078 (1.98) HIGH, BOLD FACE A FLAT .937 .013 (23.80) (.33) B Mounting Bushing Type 1 Recommended Cutout .440 - .450 DIA. (17.3 - 17.7) 7/16-28 THREAD (SILVER) Type 4 .300 (7.62) ...

Related keywords