9926252501 Weidmuller, 9926252501 Datasheet

CIRCUIT BRKR 1A 2POLE DIN RAIL

9926252501

Manufacturer Part Number
9926252501
Description
CIRCUIT BRKR 1A 2POLE DIN RAIL
Manufacturer
Weidmuller
Series
9926r
Datasheet

Specifications of 9926252501

Breaker Type
Hydraulic-Magnetic
Voltage
480VAC
Current - Trip (it)
1A
Number Of Poles
2
Actuator Type
Lever
Mounting Type
DIN Rail
Input Voltage Vac
480V
No. Of Poles
2
Current Rating
1A
Interrupting Capacity
5kA
Dielectric Strength
1.5kV
Trip Time
40s
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
281-2539
52
Circuit Breakers
Hydraulic Magnetic Type
• AC Voltages 277/480V
• Trip curve 2 for general purpose
• UL 1077 recognized
• VDE approved and CE marked
• Just 13 mm wide
• Mounts to 35 mm DIN-rail
• Factory fitted auxiliary or trip alarm
• Single, double and triple pole versions
Accessories
Bus bar (1 pole, insulated 1m)
Bus bar (2 pole, insulated 1m)
Bus bar (3 pole, insulated 1m)
Bus bar end cap, 1 pole
Bus bar end cap, 2 pole or 3 pole 67101974
Power lug, straight
Power lug, 90°
Lock-out handle
Voltage
Current
Interrupting capacity
Dielectric strength
Insulation resistance
Operating life
Operating temperature
Wire size*
Torque
† UL 1077 Recognized, VDE (EN 60947-2) Approved, CSA C22.2 No. 235, CE Marked
*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.
† cURus recognized to UL1077 and C22.2 No. 235
Ordering Data
Type
Technical Data
Approval
applications
9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s
minimum
maximum
1-15A:
20-25A:
67101904
67101972
67101971
67101973
67101960
67101961
67101913
Part No.
5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V
Current
Ratings
9926 Series
Single Pole
(amps)
9926 Series Supplemental – dimensions in mm (in.)
10
15
20
25
35
40
50
60
1
2
3
4
5
6
8
(0.2)
5.0
Type: Single Pole (up to 277 VAC)
9926251501
9926251502
9926251503
9926251504
9926251505
9926251506
9926251508
9926251510
9926251515
9926251520
9926251525
9926251535
9926251540
9926251550
9926251560
Part No.
10000 mechanical operations
14 AWG min., 10 AWG max.
277/480 VAC @ 50/60 Hz
(1.73)
(2.56)
44
65
(2.51)
(2.36)
63.8
(2.87)
60
73
1500 V, 50/60 Hz
QZ-1-13-D-2-01
QZ-1-13-D-2-02
QZ-1-13-D-2-03
QZ-1-13-D-2-04
QZ-1-13-D-2-05
QZ-1-13-D-2-06
QZ-1-13-D-2-08
QZ-1-13-D-2-10
QZ-1-13-D-2-15
QZ-1-13-D-2-20
QZ-1-13-D-2-25
QZ-1-13-D-2-35
QZ-1-13-D-2-40
QZ-1-13-D-2-50
QZ-1-13-D-2-60
Description
10 AWG min.
-40…+65°C
100 MM
20 in.-lb
0.5 A
60 A
9926 Series
Double Pole
Trip Curves—Hydraulic
Magnetic Type Typical
time/current characteristics
at 30ºC
Additional trip curves and
amp ratings are available
upon request.
Current
(amps)
Rating
9926 Series–Supplemental Trip Curve
10
15
20
25
30
35
40
50
60
Type: Double Pole (up to 480 VAC)
1
2
4
5
6
(0.51)
13
9926252501
9926252502
9926252504
9926252505
9926252506
9926252510
9926252515
9926252520
9926252525
9926252530
9926252535
9926252540
9926252550
9926252560
Part No.
QZ-2-13-D-2-01
QZ-2-13-D-2-02
QZ-2-13-D-2-04
QZ-2-13-D-2-05
QZ-2-13-D-2-06
QZ-2-13-D-2-10
QZ-2-13-D-2-15
QZ-2-13-D-2-20
QZ-2-13-D-2-25
QZ-2-13-D-2-30
QZ-2-13-D-2-35
QZ-2-13-D-2-40
QZ-2-13-D-2-50
QZ-2-13-D-2-60
Description
(1.02)
(0.51)
26
13
0.001
1000
0.01
Current
100
9926 Series
Triple Pole
Rating
(amps)
0.1
10
10
10
15
20
25
30
40
50
60
1
1
(0.51)
Type: Triple Pole (up to 480 VAC)
13
(1.54)
39
9926253510
9926253515
9926253520
9926253525
9926253530
9926253540
9926253550
9926253560
(%) Rated Current
Part No.
Ambient Temperature 30°C
Operating Characteristics
QZ-3-13-D-2-10
QZ-3-13-D-2-15
QZ-3-13-D-2-20
QZ-3-13-D-2-25
QZ-3-13-D-2-30
QZ-3-13-D-2-40
QZ-3-13-D-2-50
QZ-3-13-D-2-60
Curve 2
Description

Related parts for 9926252501

Related keywords