Specifications of 3130F110P7T1W02Q0.2A

Breaker Type
Thermal
Voltage
50VDC, 250VAC
Current - Trip (it)
200mA
Number Of Poles
1
Actuator Type
Rocker
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
302-1041
3130-F110-P7T1-W02Q-0.2AMP
3130F110P7T1W02Q0.2A
3130F110P7T1W02Q0.2AMP
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or, in the
case of the double pole version, protection on one pole only. Illumination
is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
operating voltage
6 V
12 V
24 V
48 V
115 V
230 V
415 V
* single pole version only
Authority
VDE (EN 60934)
UL, CSA
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Issue B
Description
Typical applications
Standard current ratings and typical internal resistance values
Illumination voltage/power consumption
Approvals
Internal resistance
per pole (Ω)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Voltage rating
AC 240/415 V
DC 50 V
DC 28 V
AC 250 V; DC 50 V
3 AC 250 V
Thermal Overcurrent Circuit Breaker 3130
filament/neon (B)
60 mA
20 mA
20 mA
20 mA
< 1.5 mA
< 1.5 mA
< 1 mA
power consumption
Current
rating (A) per pole (Ω)
4
5
6
7
8
10
12
14
15
16
18
20
Current rating
0.1...20 A
0.1...16 A
0.1...8 A
0.1...16 A
0.1...20 A
0.1...16 A
0.1...12 A
Internal resistance
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
LED (G, R, Y)
9 mA
9 mA
9 mA
1.5 mA
< 1 mA*
< 1 mA*
not available
single pole
multipole
multipole
single pole
1- and 2- pole
3-pole
single pole
www.e-t-a.com
Current ratings
Typical life
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
Shock
Corrosion
Humidity
Mass
For further details please see chapter: Technical Information
Voltage rating
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Technical data
AC 240 V:
DC 50 V:
DC 28 V:
AC 240 V:
DC 50 V:
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I
operating area
current path/current path AC 1,500 V
1-pole
0.1...20 A 30,000 operations at 1 x I
0.1...4 A
4.5...16 A 30,000 operations at 1 x I
4.5...20 A 30,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
cn
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
0.1...20 A
0.1...16 A
1-pole
30,000 operations at 1 x I
2-pole
3-pole
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
0.1...2 A
2.5...20 A
2.5...16 A
2.5...12 A
14 + 16 A
I N
1- + 2-pole AC 250V/3500A AC 250V/3500A
3-pole
1- + 2-pole DC 50V/2000A
operating area IP40
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
3130
0.1...12 A
3AC 250V/5000A
1-pole
2- and 3-pole
10 x I
150 A
250 A
150 A
130 A
3-pole
N
pollution
degree
2
N
N
N
N
N
N
N
, inductive
, inductive
, resistive
, inductive
, inductive
, inductive
, inductive
14...16 A
DC 50V/2000A
1-pole
2-pole
3-pole
3-pole
1 - 75
1

Related parts for 3130F110P7T1W02Q0.2A

3130F110P7T1W02Q0.2A Summary of contents

Page 1

... A single pole 0.1...16 A multipole Corrosion 0.1...20 A single pole 0.1... and 2- pole Humidity 0.1...12 A 3-pole Mass www.e-t-a.com 3130 3-pole AC 240 415 (UL: AC 250 250 0.1...20 A 1-pole 0.1... and 3-pole 1-pole 0.1...20 A 30,000 operations inductive N 0.1...4 A ...

Page 2

... V (R,Y) X LED *** Current ratings 0.1...20 A ordering example 3130 - N/A for non-illuminated version ** unprotected poles have to ordered with terminal design N7 www.e-t-a.com rocker switch/circuit breaker multipole Mounting F snap in frame Frame 1 standard Number of poles 2 2-pole, thermally protected 3 3-pole, thermally protected ...

Page 3

... A +0.3 mm inch +.012 1.50 .059 2.35 .093 3.20 .126 This is a metric design and millimeter dimensions take precedence ( mm ) www.e-t-a.com 37.5 1.48 ON 32.5 1.28 LINE I blade terminals DIN 46244-C-Ms-S .079 (QC 2x.110 P7 or N7) 20 .787 Side view LINE I ...

Page 4

... The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – Technical information Ambient temperature °F Derating factor www.e-t-a.com 1-pole switch line I.I line I.I I.3 I.2 lamp load ...

Related keywords