3400-IG8-P10-7A E-T-A, 3400-IG8-P10-7A Datasheet

no-image

3400-IG8-P10-7A

Manufacturer Part Number
3400-IG8-P10-7A
Description
CIRC BRKR THERMAL 7A 250V
Manufacturer
E-T-A
Series
3400r
Datasheet

Specifications of 3400-IG8-P10-7A

Breaker Type
Thermal-Magnetic
Voltage
65VDC, 240VAC
Current - Trip (it)
7A
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3400-IG8-P10-7AMP
Q3180530A
Single pole thermal-magnetic circuit breakers with tease-free, trip-free,
press-to-reset, snap action mechanism (R-type TM CBE to EN 60934;
M-type with manual release (-H). Available with fast acting and standard
magnetic tripping characteristics - types 3300 and 3400 - both with
threadneck panel mounting. Options include auxiliary contacts, a
separate shunt tap terminal (-A3), and pull-to-trip manual release (-H).
Approved to CBE standard EN 60934 (IEC 60934).
Control systems, instrumentation, medical equipment, machine tools,
robotics.
Type No.
3300
3400
3400 - iG2 - P10 - .. - .. - Si - .. - 10 A
3400 - ... - P10 - .. - H - Si - .. - 10 A
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Current
ratings (A) 3300
0.05
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.5
2
2.5
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
fast acting
standard delay
Mounting
iG2
...
moulded threadneck M12x1 (bulk-shipped), not with -H;
leave blank for metal threadneck, required for -H
Terminal design
P10
K20
Internal resistance (Ω)
447
131
41
19.6
10.4
7.2
4.8
2.5
1.93
0.81
0.44
0.27
blade terminals 6.3-0.8 (QC .250)
screw terminals M3.5x5.5 with clamp (not for -Si and -A3)
Shunt terminal (optional)
A3
Thermal-Magnetic Circuit Breakers 3300/3400
same as main terminals, up to I
Manual release (optional)
H
3400
211
131
40
19.3
10.4
7.1
4.3
2.5
1.67
0.61
0.38
0.24
manual release facility (pull), without
reinforced insulation in operating area,
for M12x1 metal threadneck only.
Metal threadneck version for -H is not approved.
Auxiliary contacts (optional)
Si
with silver-plated solder terminals
(N/O and N/C)
Push button marking (optional)
1
without
Current ratings
0.05...16 A
Current
ratings (A) 3300
3
4
5
6
7
8
10
12
13
14
15
16
ordering example, without manual
release and with moulded
threadneck
ordering example, with manual
release and metal threadneck
Internal resistance (Ω)
0.18
0.109
0.066
0.046
0.032
0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
N
=7 A max. load 5 A
0.19
0.090
0.061
0.041
0.034
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
3400
www.e-t-a.com
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
Degree of protection
Humidity
Mass
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(UL 1077)
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Authority
VDE (EN 60934)
CSA, UL
UL: only type 3400
Technical data
Approvals
with -H:
without -H: 0.05...8 A 5,000 operations at 2 x I
operating area
operating area
main circuit/aux. circuit AC 1,500 V
aux. circuit 4-5/6-7
> 8 A
cn
fast acting
3300
Voltage ratings
AC 240 V; DC 65 V
AC 250 V; DC 80 V
DC 65 V
AC 240 V, 50/60 Hz; DC 65 V
(UL: AC 250 V; DC 80 V)
0.05...16 A
1 A, AC 240 V / DC 65 V
5,000 operations at 1 x I
5,000 operations at 2 x I
1,500 operations at 2 x I
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V double insulation
AC 840 V
> 100 MΩ (DC 500 V)
0.05...0.8 A
1...2 A
2.5...16 A
I
0.05...16 A
0.05...16 A
operating area IP40
terminal area IP00
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
25 g (11 ms) to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
3300: approx. 55 g
3400: approx. 50 g
N
3400
standard delay
self-limiting
200 A
400 A
U
AC 250 V
DC 80 V
N
Current ratings
0.05...16 A
0.05...16 A
0.05...25 A
pollution
degree
2
N
N
N
N
, inductive
, resistive
, inductive
, inductive
1,000 A
1,000 A
2 - 49
2

Related parts for 3400-IG8-P10-7A

3400-IG8-P10-7A Summary of contents

Page 1

... N/C) Push button marking (optional) 1 without Current ratings 0.05...16 A 3400 - iG2 - P10 - .. - .. - ordering example, without manual release and with moulded threadneck 3400 - ... - P10 - .. - ordering example, with manual release and metal threadneck The exact part number required can be built up from the table of choices shown above ...

Page 2

... Thermal-Magnetic Circuit Breakers 3300/3400 Dimensions -iG2-P10 ø6.4 .252 M12x1 tightening torque max. 1 blade terminals DIN 46244-A6.3-0.8 (QC .250) 42 1.65 29 1.14 5 current rating ø6.4 .252 M12x1 mounting holes ø3 +0.2 +.008 .118 Installation drawing operating area (reinforced insulation .118 .039 mounting area Internal connection diagrams Terminal design 14 ...

Page 3

... Type 3400 0.05 … +60 °C 10000 +140 °F +23 °C +73.4 °F 1000 -30 °C -22 °F 100 10 1 0.1 0.01 0.001 1 1) Type 3400 8 … +60 °C 10000 +140 °F +23 °C +73.4 °F 1000 -30 °C -22 °F 100 10 1 0.1 0.01 0.001 1 1) Magnetic tripping currents are increased by 20 supplies. ...

Related keywords