2210-S231-P1T1-HO-16A E-T-A, 2210-S231-P1T1-HO-16A Datasheet

no-image

2210-S231-P1T1-HO-16A

Manufacturer Part Number
2210-S231-P1T1-HO-16A
Description
CIRC BREAKER THERM MAGNETIC 16A
Manufacturer
E-T-A
Series
2210r
Datasheet

Specifications of 2210-S231-P1T1-HO-16A

Breaker Type
Thermal-Magnetic
Voltage
65VDC, 277VAC
Current - Trip (it)
16A
Number Of Poles
3
Actuator Type
Toggle
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2210-S231-P1T1-HO-16AMP
Q3052412
One, two and three pole thermal-magnetic circuit breakers with trip-
free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC
934). Designed for panel or plug-in mounting. Available with auxiliary
contacts (1 x N/O, 1 x N/C) for status signalling. Two and three pole
models are internally linked to ensure that both/all poles trip in the
event of an overload on one pole, even if the actuator is held in the ON
position. A choice of characteristic curves further extends the range of
applications possibilities for these CBEs. Special auxiliary contact
versions for industrial atmosphere and low voltages (e.g. 5 V) available
on request.
Approved to CBE standard EN 60934 (IEC 60934).
Suitable for use in distribution rails – see section 7.
Process control equipment, robotics, machine tool control, communications
systems, instrumentation, rail vehicles. Special versions, e.g. for aggressive
environmental conditions and low voltages (e.g. 5 V) on request.
Type No.
2210
2210 - S 2 1 0 - P1 F1 - H 1 1 1 - 10 A
Remote trip coil available to special order.
Issue B
Description
Typical applications
Ordering information
single or multipole thermal-magnetic circuit breaker
Mounting
S
socket or panel mounting
Actuator design
2
toggle
Number of poles
1
2
3
5
1-pole protected
2-pole protected
3-pole protected
2-pole, protected on one pole only
Panel mounting
0
1
2
without hardware
with M3 thread
with 6/32 thread
Terminal design (main contacts)
P1
blade terminals 6.3-0.8 (QC .250)
Characteristic curve
F1
F2
M1
T1
T2
M3
Thermal-Magnetic Circuit Breaker 2210-S2..
fast acting: therm.1.01-1.4xI
fast acting: therm.1.01-1.4xI
magn.3.5-6.5xI
standard delay: therm. 1.01-1.4xI
magn. 6-12xI
delayed: therm. 1.01-1.4xI
thermal only, 1.01-1.4xI
standard delay, low resistance: therm.1.4-1.8xI
magn. 6-12xI
Intermediate position
H
Z
without intermediate position (standard)
with intermediate position
Auxiliary contacts
0
1
2
3
without auxiliary contacts
with auxiliary contacts in all poles
with auxiliary contacts in pole 1
(only multipole devices)
with auxiliary contacts in poles 1 and 3
(≥ 3-pole devices)
Auxiliary contact function (see diagram)
1
2
3
one each N/C and N/O (standard)
one N/O contact (23/24)
one N/C contact (11/12)
Auxiliary contact - terminal design
1
same as main terminals
Current ratings
0.1...25 A
N
N
N
AC;7.8-15.6xI
AC; 7.8-15.6xI
AC/ 4.5-8.5xI
ordering example
N
N
;magn.2-4xI
N
; magn. 10-20xI
N
N
;
N
N
DC
DC
DC
N
;
N
DC (DC only)
N
www.e-t-a.com
AC
N
;
Current rating range
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
(UL 1077)
Shock
Corrosion
Humidity
For further details please see chapter: Technical Information
Voltage rating
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Mass
Technical data
operating area
main/aux. circuit
aux. circuit 11-12/23-24 AC 1,000 V
pole/pole
curves M1, M3, T1, T2: 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
curves M1, M3, T1, T2: 25 g (11 ms), directions 1, 2, 3, 4, 5
curve F1: 3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
curve F1: 25 g (11 ms), directions 1, 2, 3, 4, 5
I
U
1-pole
2-pole
3-pole
N
N
cn
AC 250 V*; 3 AC 433 V (50-60Hz); DC 65 V
(*UL: AC 277 V; DC 65 V)
0.1...25 A for curves M1, T1, T2
0.1...16 A for curves F1, F2, M3
1 A, AC 240 V/DC 65 V
10,000 operations at 1 x I
-30...+60 °C (-22...+140 °F) T 60
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...5 A 400 A; 6...25 A 800 A
curve T2 : 0.1...25 A 15 x I
curve M3: 0.1...2 A AC 200 A / DC 400 A
0.1...8 A
AC 250 V
1,000 A
2,000 A
3AC 250V
2,000 A
operating area IP30
terminal area IP00
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
10 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
96 hours in 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 50 g per pole
20 g (11 ms), direction 6
2210-S2..
10...16 A
AC 125 V
2,000 A
2,000 A
3AC 250V
2,000 A
20...25 A
AC 250 V DC 65 V
3,500 A
3,500 A
3AC 216V
3,500 A
pollution
degree
2
N
N
, inductive
0.1...25 A
2,000 A
2,000 A
2 - 11
2

Related parts for 2210-S231-P1T1-HO-16A

2210-S231-P1T1-HO-16A Summary of contents

Page 1

... N/O contact (23/24) 3 one N/C contact (11/12) Auxiliary contact - terminal design 1 same as main terminals Current ratings 0.1...25 A 2210 - ordering example Remote trip coil available to special order. Issue B Technical data For further details please see chapter: Technical Information Voltage rating Current rating range ...

Page 2

... Thermal-Magnetic Circuit Breaker 2210-S2.. Standard current ratings and typical internal resistance values Current Internal resistance (Ω) rating (A) fast acting fast acting standard delay for DC only for for nur für AC 0.1 162 162 92 0.2 39.3 39.3 26.1 0.3 17.5 17.5 11.6 0.4 9 ...

Page 3

... Thermal-Magnetic Circuit Breaker 2210-S2.. Internal connection diagrams with auxiliary contact function 1 (one each N/O and N/C) (...-H111-...) without intermediate position (...-Z111-...) with intermediate position (Z) line (Z) line > I > 2(k) 2(k) OFF position intermediate position The time/current characteristic curve depends on the ambient temperature prevailing ...

Page 4

... Thermal-Magnetic Circuit Breaker 2210-S2.. The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 – Technical information. Ambient temperature °F -22 -4 +14 +32 +73.4 +86 +104 +122 +140 ° ...

Page 5

... Thermal-Magnetic Circuit Breaker 2210-S2.. Module 17plus For technical data see section 7 - Power distribution systems slot for fitting labels from Phoenix, Weidmüller, Wieland 17 plus 63 G-profile EN 50035-G32 2.48 115 4.53 symmetrical rail EN 50022-35x7.5 slot for busbar module 2-way 6-way mounting socket mounting socket ...

Page 6

... X 211 117 02 31 1.22 ø16.8 .661 fixing plate 39 1.54 32 1.26 Splash cover (transparent) with fixing plate and screws (IP54) for type 2210-S221-… (2-pole) and type 2210-S231-… (3-pole) X 211 118 01 38 1.50 24.5 .965 fixing plate 53 2.09 ±0.1 32 1.26 ± ...

Related keywords