4430.1353 Schurter Inc, 4430.1353 Datasheet

no-image

4430.1353

Manufacturer Part Number
4430.1353
Description
CIRCUIT BRKR ROCKER 5A 2POLE QC
Manufacturer
Schurter Inc
Series
TA45r
Datasheets

Specifications of 4430.1353

Breaker Type
Thermal
Voltage
125/250VAC
Current - Trip (it)
5A
Number Of Poles
2
Actuator Type
Rocker
Mounting Type
Panel Mount
Alt Mfr.s Type
TA45-ABTBL050C0
Brand/series
ABT Series
Color, Button
Black
Current Rating
5 A
Current, Rating
5 A
Dielectric Strength
1.5 kV (Min.)
Dimensions
36 mm L x 43 mm W x 91.5 mm H
Standards
cUL Recognized, VDE Approved
Terminal Style
Quick-Connect
Voltage, Rating
125⁄250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CBE TA45-ABTBL050C0
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON
GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT
Product description
The 2 pole, push button actuated version of the TA45 line of thermal
CBE’s can be used for various purposes. Basically it is a CBE for
automatic interruption of overloads with facilities for regular manual
ON/OFF switching operations under normal load conditions. It is
capable of interrupting moderate short circuit currents without the aid
of back-up protection.
A special version is available as a «CBE-switch», in which the means
for automatic overcurrent interruption (the bimetal relases), are
omitted.
Another available version of this line utilizes an under-voltage release
to protect persons against injuries caused by unexpected events like
the automatic restarting of motors after a power failure. This release
can be combined with the thermal release required for overcurrent
protection. Protection against injuries is also provided by another
CBE of this line, which prevents the starting of a machine should a
protective cover be removed from dangerous parts of the machine.
Available options
• CBE for overcurrent protection
• CBE with undervoltage release:
• CBE switch with mechanical lock-out latch:
• CBE with remote trip release:
• CBE with auxiliary contact:
TA45 is positively trip-free. The rated current range is 0,05 to 20 A at
AC 240 V / DC 60 V . The CBE comes with snap-in mounting or
flange mounting. A locking device suitable for padlocks prevents
unauthorized switching ON of the CBE. The TA45 is approved in all
major industrial countries and complies with the CBE-standard
EN60934.
In conjunction with its accessories the TA45 product line of Schurter
paves the way for new unconventional applications.
Applications
• Motors
• Power supplies
• Processing machines
• etc.
70
1 or 2 protected poles (thermal)
The CBE will open automatically when the voltage drops below the
trip level. Only when the supply voltage has reached the reset level,
the CBE can be reclosed manually.
A spring loaded pin will trip the CBE if a protective cover of the
equipment is removed. The CBE can not be switched ON until the
protective cover is refitted.
The remote trip release permits the CBE to be tripped by a external
contact (sensor) energizing the trip coil.
All types of the line can be outfitted with an auxiliary contact
(changeover contact).
www.schurter.com
Produktebeschreibung
Die 2polige, drucktastenbetätigte Version der TA45-Linie ist ein ther-
mischer Geräteschutzschalter, kurz CBE (Circuit Breaker for
Equipment) genannt, der für viele Zwecke eingesetzt werden kann. In
seiner Grundausführung ist dieser CBE für die automatische
Unterbrechung von Überlast-Strömen und das manuelle
Wiedereinschalten resp. für manuelles EIN/AUS-Schalten im Normal-
betrieb bestimmt. Der CBE ist in der Lage, Überströme bis zu seinem
Schaltvermögen ohne back-up Unterstützung zu unterbrechen.
Eine spezielle Version ist erhältlich als «CBE-switch». Bei dieser
Ausführung fehlt der Thermo-Auslöser. Eine weitere Version der
TA45-Linie ist mit Unterspannungsauslösung ausgerüstet. Diese
schützt Personen vor möglichen Verletzungen wie sie z.B. durch
unbeabsichtigtes Wiederanlaufen von Geräten nach einem
Netzausfall verursacht werden könnten. Dieser Schutz kann mit dem
thermischen Überlast-Schutz kombiniert werden. Schutz gegen
Verletzungen wird auch gewährleistet durch eine weitere Version der
TA45-Reihe, die den Anlauf einer Maschine verhindert, bei der eine
wichtige Schutzabdeckung fehlt.
Erhältliche Versionen
• Geräteschutzschalter mit Überstromauslösung:
• Geräteschutzschalter mit Unterspannungsauslöser:
• Geräteschutzschalter mit mechanischer Schaltsperre:
• Geräteschutzschalter mit Fernauslösung:
• Geräteschutzschalter mit Hilfskontakt:
Der TA45 ist positiv freiauslösend. Sein Nennstrombereich beträgt
0,05 bis 20 A bei AC 240 V / DC 60 V . Die Montage erfolgt mittels
Schnappbefestigung oder Flanschbefestigung. Mit einer zusätzlichen
Abschliessvorrichtung für ein Vorhängeschloss lässt sich der TA45
gegen unbefugtes Einschalten sichern. Der TA45 ist in den wichtig-
sten Industrieländern approbiert und entspricht der neuen CBE
Europa Norm EN60934. In Verbindung mit dem vielfältigen Zubehör
ermöglicht der 2polige drucktastenbetätigte TA45 von Schurter neue,
unkonventionelle Anwendungen.
Anwendungen
• Motoren
• Netzgeräte
• Be- und Verarbeitungsmaschinen
• usw.
Ein- oder zweipolig geschützt durch Thermo-Bimetall
Wiederanlaufschutz bei Spannungsausfall. Nach Unterschreiten
der Abfallspannung (Netzausfall) springt der Geräteschutzschalter
in die AUS-Stellung. Ein manuelles Einschalten ist erst dann
möglich, wenn die wiederkehrende Spannung den Anzugswert
des Auslösers erreicht.
Ein unter Federdruck stehender Stift bewirkt ein automatisches
Auslösen, falls die Schutzabdeckung entfernt wird. Ein Wieder-
einschalten in dieser Position ist nicht möglich, solange die Ab-
deckung fehlt.
Der Fernauslöser ermöglicht das Ausschalten durch einen
externen Schalter oder Sensor, der die Auslösespule aktiviert.
Alle Typen sind mit einem Hilfskontakt (Wechselkontakt) erhältlich.
TA45

Related parts for 4430.1353

4430.1353 Summary of contents

Page 1

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Product description The 2 pole, push button actuated version of the TA45 line of thermal CBE’s can be used for various purposes. Basically CBE for automatic interruption of overloads with facilities for regular manual ON/OFF switching operations under normal load conditions ...

Page 2

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Effect of ambient temperature The unit is calibrated for an ambient tem- perature of +23°C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below: *Ambient Correction factor temperature [° ...

Page 3

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Technical data / Technische Daten Rated voltage U e Nennspannung U e Rated current I n Nennstrom I n Conditional short circuit current I nc Bedingtes Schaltvermögen I nc Short circuit capacity I cn Schaltvermögen I cn ...

Page 4

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Technical data (continued) / Technische Daten (Fortsetzung) Auxiliary contact (changeover) / Hilfskontakt (Wechsler) Rated voltage Nennspannung Rated current Max. Nennstrom Undervoltage release / Unterspannungs-Auslöser Max. operating voltage Max. Betriebsspannung Rated operating voltage U e Nennbetriebsspannung U e Current consumption (± ...

Page 5

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Order code 2 pole, push button actuated Basic type Grundtyp Auxiliary contact (changeover) / Hilfskontakt (Wechsler) Shunt terminal / Nebenanschluss Terminal type Quick connect terminal Anschlussart Screw type terminal (lineside P1, P2) Schraubanschluss (Netzeingang P1, P2) ...

Page 6

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT 1 pole thermal overload protection 1poliger thermischer Überstromschutz • • • • • • • ABL AEL ABM AEM AUL ABU AEU ABV AEV AUU AHL AJL AHM AJM ALL ...

Page 7

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Order code accessories 2 pole, push button actuated Bestellcode Zubehör 2polig, drucktastenbetätigt For subsequent fitting / Nachträglich montierbar AZZ05 Order example Bestellbeispiel Available accessories / Einsatzmöglichkeiten 2 pole version 2polige Ausfü ...

Page 8

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Snap-in type and quick connect terminals Basic type / Grundtyp 59 50 23.7 44 5.3 8.4 26.7 Undervoltage release, remote trip release 59 50 23.7 44 1.5 22 6.3 5.3 26.7 8.4 Mechanical lock-out latch ...

Page 9

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Snap-in type and screw clamp terminal Basic type / Grundtyp Position on / Stellung ein Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulässiger Anzugsdrehmoment 1 Nm Cut-out and pin-out / Montageö ...

Page 10

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Accessories / Zubehör AZZ71 AZZ72 AZZ73 CBE switchable / CBE einschaltbar 89.4 8.7 21.6 AZZ51 Snap-on fastener / Schnapphaken 54.6 x 28.3 CBE not switchable / CBE nicht einschaltbar 89.4 28.1 20.1 TA45 www ...

Page 11

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Snap-in type and quick connect terminals Basic type with auxiliary contact / Grundtyp mit Hilfskontakt 59 50 23 5.3 11.6 7.5 8.4 7.6 Undervoltage release, remote trip release ...

Page 12

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Snap-in type and screw clamp terminal Basic type with auxiliary contact / Grundtyp mit Hilfskontakt Position on / Stellung ein Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulä ...

Page 13

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Accessories / Zubehör AZZ81 AZZ82 AZZ83 CBE switchable / CBE einschaltbar 89.4 8.7 21.6 82 www.schurter.com CBE not switchable / CBE nicht einschaltbar 89.4 28.1 20.1 59 TA45 ...

Page 14

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Flange type and quick connect terminals Basic type / Grundtyp 74 50 23.7 44 5.3 8.4 26.7 Undervoltage release, remote trip release 74 50 23.7 44 1.5 22 6.3 5.3 8.4 26.7 Mechanical lock-out latch ...

Page 15

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Flange type and screw clamp terminal Basic type / Grundtyp Position on / Stellung ein Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulässiger Anzugsdrehmoment 1 Nm Cut-out and pin-out / Montageö ...

Page 16

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Accessories / Zubehör AZZ05 72 Ø 4.5 Ø 3.8 AZZ51 Snap-on fastener / Schnapphaken 54.6 x 28.3 34 TA45 www.schurter.com 85 ...

Page 17

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Flange type and quick connect terminals Basic type with auxiliary contact / Grundtyp mit Hilfskontakt 74 50 23 5.3 11.6 7.6 7.5 8.4 Undervoltage release, remote trip release ...

Page 18

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Flange type and screw clamp terminal Basic type with auxiliary contact / Grundtyp mit Hilfskontakt Position on / Stellung ein Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulä ...

Page 19

... CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERÄTESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETÄTIGT Accessories / Zubehör AZZ05 72 Ø 4.5 Ø 3.8 88 www.schurter.com 34 TA45 ...

Related keywords