BCCM6033SQ Cooper/Bussmann, BCCM6033SQ Datasheet

no-image

BCCM6033SQ

Manufacturer Part Number
BCCM6033SQ
Description
FUSEBLOCK CLASS CC 13/32X1-1/2"
Manufacturer
Cooper/Bussmann
Series
BCCMr
Type
Blockr
Datasheet

Specifications of BCCM6033SQ

Fuse Size
Class CC
Number Of Circuits
3
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Current Rating
20A
Product
Block
Fuse Size / Group
Class CC
Voltage Rating
600 Volts
Mounting Style
Screw
Body Material
Thermoplastic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Bussmann
®
Circuit Protection Solutions

Related parts for BCCM6033SQ

BCCM6033SQ Summary of contents

Page 1

... Bussmann Circuit Protection Solutions ® ...

Page 2

... Bussmann Worldwide Circuit Protection Solutions This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog ...

Page 3

Section Guide 1 Electrical – Power Fuses 2 Electronic – PC Board and Small Dimension Fuses 3 Fuseblocks and Holders 4 Disconnect Switches 5 High Speed Fuses 6 Medium Voltage Fuses and Fuse Links 7 Telecommunications Protection 8 British, European, ...

Page 4

... British, European, & Canadian Standard Industrial Fuses CSA Type P and D Fuses . . . . . . . . . . . . . . . . . . . . . . . .190 HRC Industrial Fuses . . . . . . . . . . . . . . . . . . . . . . . .191-195 BS88 Low Voltage Industrial Fuses . . . . . . . . . . . . . .196-197 DIN Style Type D and Neozed Fuses . . . . . . . . . . . . . . . .198 HRC Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199 NH Fuse System . . . . . . . . . . . . . . . . . . . . . . . . . .200-201 Fuse Accessories, Displays, Kits, Etc. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204 Display Racks and Service Kits ...

Page 5

... Moderate degree of 12 current limitation. Time-delay 13 passes surge currents. 14 All-purpose fuse. Time- 8 delay passes surge-currents. Same short-circuit protection 15 as LOW-PEAK fuses but must be sized larger for circuits with surge-currents; i.e 300%. A fast acting, high 8 performance fuse. All-purpose fuses. ...

Page 6

General Data – Dimensions (Inches) CLASS T T-Tron™ Fuses JJN (300V) JJS (600V) 2 CLASS J Low-Peak ® & Limitron ® Fuses LPJ & JKS (600V) CLASS L Low-Peak ® & Limitron KRP-C, KTU, & KLU (601 - 6000A) (600V) ...

Page 7

General Data – Dimensions (Millimeters) CLASS T T-Tron™ Fuses JJN (300V) JJS (600V) CLASS J Low-Peak ® & Limitron ® Fuses LPJ & JKS (600V) CLASS L Low-Peak ® & Limitron ® KRP-C, KTU, & KLU (601 - 6000A) (600V) ...

Page 8

... Conventional Class J fuse case sizes and ampere ratings. • Dovetail fuseholder design for ganging multiple fuse poles. • 30 and 60 Amp fuseholders can be ganged together. • 30 Amp fuses can be plugged into the 60A holder without a reducer. • 35mm DIN rail and chassis mounting features. ...

Page 9

Electrical - Power Fuses CUBEFUSE™ and Fuseholder Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Dimensional Data For TCF and TCFH Dimension 30A in [mm] A 1.88 [47.75] B .75 [19.05] C 1.00 [25.40] D .31 [7.94] E ...

Page 10

... All-purpose silver linked fuse for both overload and short- circuit protection for high capacity systems (mains and large feeders). • Time-delay (minimum of four seconds at five times amp rating) for close sizing. • Current limiting action of the fuse generally affords consider- able reduction in bus bracing. • ...

Page 11

Electrical - Power Fuses Time-Current Characteristic Curves—Average Melt KRP-C 300 100 .01 CURRENT IN AMPERES KRP-CL Current Limiting, Time-Delay Construction: Glass Melamine Tube Ampere Ratings: 150-600A. Voltage Rating: 600Vac (or less) These fuses have the same performance ...

Page 12

Electrical - Power Fuses ® Limitron Class L Fuses KTU Fast Acting, Bolt Mount Ampere Ratings: 601-6000A. Voltage Rating: 600Vac (or less) Interrupting Rating: 200,000 RMS Sym. Agency Information: Std. 248-10, Class L UL Listed, Guide JDDZ, File E4273 CSA ...

Page 13

... Tin plate option. (Ex: LPS-RK-100SP-TP) Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 • Current limitation for maximum short-circuit protection. High speed of response is highly sensitive to fault currents, but insensitive to starting current and transient surges. ...

Page 14

Electrical - Power Fuses ® Low-Peak Dual-Element, Time-Delay, Class RK1 Fuses Time-Current Characteristic Curves—Average Melt 100 200 400 600 300 100 .01 CURRENT IN AMPERES 300 100 .01 CURRENT IN ...

Page 15

Electrical - Power Fuses ® Low-Peak Dual-Element, Time-Delay, Class RK1 Fuses Recommended fuseblocks for Class R 250 & 600V fuses See pages 47-52 Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600) For complete specification data, call Bussmann Information Fax ~ ...

Page 16

Electrical - Power Fuses ® Fusetron Dual-Element, Time-Delay, Class RK5 Fuses FRN-R (250V) Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: -600A. Voltage Rating: 250Vac (or less), 125Vdc Current Limiting RK5 Fuse Interrupting Rating: 200,000A RMS ...

Page 17

Electrical - Power Fuses ® Fusetron Dual-Element, Time-Delay, Class RK5 Fuses FRS-R (600V) Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: -600A. Voltage Rating: 600Vac (or less), 300Vdc Current Limiting RK5 Fuse Interrupting Rating: 200,000A RMS ...

Page 18

Electrical - Power Fuses Dura-Lag Dual-Element, Time-Delay, Class RK5 Fuses ™ DLN-R (250V) Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: 1-600A Voltage Rating: 250Vac (or less), 125Vdc Current Limiting RK5 Fuses Interrupting Rating: 200,000A RMS ...

Page 19

Electrical - Power Fuses ® Limitron Fast Acting, Class RK1 Fuses KTN-R (250V) Fast Acting Ampere Ratings: 1-600A Voltage Rating: 250Vac (or less). Current Limiting RK1 Fuse (curves on page 205) Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-12, ...

Page 20

Electrical - Power Fuses One-Time General Purpose Fuses NON and NOS General Purpose Application Non-Current Limiting Ampere Ratings: -600A Voltage Rating: 250Vac, 125Vdc (0-100A); NOS: 600Vac Interrupting Rating: 50,000A RMS Sym. (0-60A), 10,000A RMS Sym. (65-600A), 50,000A @ 125Vdc (NON ...

Page 21

... Recommended fuseblocks/fuseholders for Class J 600V fuses • Open fuseblocks - see pages 53-55 • Finger-safe fuseholders for 30A & 60A- see pages 57-58 • Modular fuseblocks - see page 67 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Time-Current Classification Curves—Average Melt ...

Page 22

... Data Sheet: 1026 (1-60A), 1027 (70-600A) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann Recommended fuseblocks/fuseholders for Class J 600V fuses • Open fuseblocks - see pages 53-55 • Finger-safe fuseholders for 30A & 60A- see pages 57-58 • Modular fuseblocks - see page 67 Cat. Weight Cat. ...

Page 23

... Data Sheet: 1029 Recommended fuseblocks/fuseholders for Class T 600V fuses • Open fuseblocks - see pages 61-62 • Modular fuseblocks - see page 67 Bussmann JJS-30 JJS-90 JJS-250 JJS-35 JJS-100 JJS-300 JJS-40 ...

Page 24

... For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann Physical Size: Fuse (Amps) (Length) A SC- to -15 1.31 (Length) SC-20 1.41 SC-25 to -30 1.63 SC-35 to -60 2.25 .41" (10.3mm) Recommended fuseblocks/fuseholders for Class G • Open fuseblocks - see page 64 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 ® ...

Page 25

... LP-CC-7 Recommended fuseblocks/fuseholders for Class CC 600V fuses • Open fuseblocks - see page 64 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Time Current Characteristics—Average Melt ...

Page 26

... FNQ-R-1 FNQ-R-6 Time-Current Curves on page 225. Recommended fuseblocks/fuseholders for Class CC 600V fuses • Open fuseblocks - see page 64 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 22 KTK-R Limitron Fast Acting; Branch Circuit Fuse ...

Page 27

... Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 28

... Data Sheet: 2011 (0-30) Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 24 BAN ...

Page 29

... FNQ-3 IR 10,000A @ 125Vac Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 Data Sheet: 2028 ® Bussmann - 30A ...

Page 30

... Ampere Ratings: - 12A Voltage Rating: 125Vac IR: 10,000A RMS Sym. Element is a simple fusible, metal link. For general purpose circuit protection. Quickly opens when short-circuit or overload occurs. Use for lighting and other non-motor circuits. Edison base. Agency Information: Std. 248-11 UL Listed, Guide JEFV, File E12112 ...

Page 31

... Motor Circuits ENA Edison base neutral For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Dual-Element Fustat Motor Protection. (Both Motor Running and Short-Circuit Protection) Adaptor Accepts Fuses SA-1 S-1 or smaller SA-1-1/4 S-1-1/4 or smaller SA-1-6/10 S-1-6/10 or smaller SA-2 S-2 or S-1-8/10 ...

Page 32

... Crimp Tool: TBM-14M • Die: 15506 KDM 15515 KDR Data Sheet: 1042 28 68000 & 64000 Series Welder Limiters for Class H and J Fuseholders Voltage Rating: 600Vac or less Interrupting Rating: 200,000 Amps RMS Symmetrical Catalog Symbol & Current Ratings Type Fuseholder Cable ...

Page 33

Electronic – PC Board and Small Dimension Fuses 5mm ≈ 15mm Fuses C515 (Axial Leads) C519 Time-Delay Physical Size: 0.197 0.591 (5mm 15mm) Construction: Glass Tube Agency Information: UL Listing File E19180, Guide JDYX 125mA-250mA and 375mA-3A CSA Certification File ...

Page 34

Electronic – PC Board and Small Dimension Fuses 5mm ≈ 20mm — IEC Standards GDA GDA-V (Axial Leads) Fast-Acting, High Breaking Capacity Physical Size: 0.197 0.788 (5mm 20mm) Construction: Ceramic Tube End caps: Nickel plated brass Voltage Rating: 250Vac or ...

Page 35

Electronic – PC Board and Small Dimension Fuses 5mm ≈ 20mm – N. American Standards GMA GMA-V (Axial Leads) Fast Acting Physical Size: 0.197 0.788 (5mm 20mm) Construction: Glass Tube End Caps; nickel plated brass Agency Information: Std. 248-14 UL ...

Page 36

Electronic – PC Board and Small Dimension Fuses ⁄Ω ¢ ∑ Diameter ≈ fiΩ• ∑ to 1∑ Lengths AGA AGA-V* (Axial Leads) Fast Acting Physical Size: (6.4mm 15.9mm) Construction: Glass Tube Voltage Rating: See table below. Agency Information: Std. 248-14 ...

Page 37

Electronic – PC Board and Small Dimension Fuses ⁄Ω ¢ ∑ Diameter ≈ 1∑ Lengths TDC180 British Household Plug Fuse Fast/Medium Physical Size: (6.4mm 25.4mm) Construction: Ceramic Tube End Caps: Silver-plated copper Agency Information: BS1362, IEC 269-3A Catalog Symbol & ...

Page 38

Electronic - PC Board and Small Dimension Fuses ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fast Acting Fuses TDC10 Fast Acting Physical Size: (6.3mm 32mm) Construction: Glass Tube Voltage Rating: See Below Agency Information: Conforms to British Standard BS-2950A, I.R. ...

Page 39

Electronic - PC Board and Small Dimension Fuses ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fuses GBB GBB-V (Axial Leads) Very Fast Acting Physical Size: (6.3mm 32mm) Construction: Ceramic Cartridge Nickel Plated Brass End Caps Voltage Rating: 250Vac/125Vdc Interrupting Rating: ...

Page 40

Electronic - PC Board and Small Dimension Fuses ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ and ⁄‹Ω£™∑ ≈ 1⁄Ω ™ ∑ Fuses MDQ MDQ-V (Axial Leads) Dual Element Time-Delay Physical Size: (6.3mm 32mm) Construction: Glass Tube; Nickel Plated Brass End ...

Page 41

Electronic - PC Board and Small Dimension Fuses Pin Indication Type GBA and GLD Fast Acting Physical Size: (6.6mm 31.8mm) Agency Information: Std. 248-14 UL Listed, 0-5A/125Vac, 10,000 AIC, Guide JDYX, File E19180 UL Recognized, 6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC ...

Page 42

Electronic - PC Board and Small Dimension Fuses Pin Indication Type/Actuators/Limiters MIS Non-Time-Delay Physical Size: (10.3mm 50.8mm) Voltage Rating: 600Vac Interrupting Rating: 200,000 AIC Catalog Symbol & Current Ratings 600Vac MIS- MIS-4 MIS-10 MIS- MIS-5 MIS-12 MIS- MIS-8 Test Specifications ...

Page 43

... Electronic - PC Board and Small Dimension Fuses In-Line Fuse and Fuseholders GLR Fast Acting, Non-rejecting Voltage Rating: 300Vac or less Interrupting Rating: 10,000A Agency Information: Std. 248-14 UL Listed, 0-15A/300Vac (Guide JDYX, File E19180) CSA Certified, 0-10A/300V (Class 1422-01, File 53787) Electrical Ratings for Type GLR Fuses ...

Page 44

... MAX Maxi–Fuse ® Fast Acting Voltage Rating: 32Vdc Interrupting Rating: 1,000A Catalog Symbol & Current Ratings MAX-20 Yellow MAX-30 Green MAX-40 Orange MAX-50 Red MAX-60 Blue MAX-70 Tan MAX-80 Clear Refer to page 82 for In-Line Fuseholders for Blade Type Fuses. Data Sheet: 2049 ...

Page 45

For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 1109 ...

Page 46

Fuseblocks, Holders and Terminal Blocks Optima ® Three Pole Overcurrent Protection Module Optional Accessories Dimensional Data Millimeters (± 0.38) Inches (± .015) Data Sheet: 1109 42 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann ® ...

Page 47

For complete specification data, call Bussmann Information Fax ~ 636.527.1450 3.22∑ (± .03) (81.8mm) (± .76) 2T1 4T2 1.76 ∑ (± .03) (44.7mm) (± 6T3 3.60 ∑ (± .03) (91.4mm) (± ...

Page 48

Catalog Number Electrical Rating Data Sheet: 1103 1.38 ∑ (35.0mm) .224 ∑ 1.312 ∑ (5.6mm) (± .01) (33.3mm) (± .25) Panel Mounting Hole Pattern SC Remote Open Rating Clips Fuse Indication For complete ...

Page 49

Blank Page 45 Do Not Print ...

Page 50

Guides: 12041, 12042, 12043, Data Sheet: 12044, 12045, 12046, 12048, 12049) TEST PROBE CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for ...

Page 51

R250, ⁄Ω ¡ º 101 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ≈ Data Sheet:H250 Series,1112; R250 Series, 1110 ...

Page 52

Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 250V Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R, DLN-R and KTN-R Fuses) Dimensional Data 250V ⁄Ω ¡ ºA to 30A 1.41" 1.09" 0.22" 0.17" 0.75" 1.27" 3.03" ...

Page 53

Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 250V 250V, 31A to 60A FIGURE 4. 250V, 61A to 100A 1.81" 0.59" 2.06" 0.25" 0.62" 7.36" FIGURE 7. 250V, 101A to ...

Page 54

Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 600V H600 Series R600 Series Construction: Ampere Ratings: Withstand Ratings: Voltage Rating: Agency Information: Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses) Data Sheet: H600 Series, ...

Page 55

Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 600V Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, DLS-R and KTS-R Fuses) Dimensional Data 600V, ⁄Ω ¡ º to 30A and 61A to 100A ...

Page 56

Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 600V Dimensional Data 600V, 31A to 60A 7.36" 600V, 101A to 600A 0.34 DIAMETER 0.75" C'BORE D FIGURE 7 600V, 201A ...

Page 57

Fuseblocks, Holders and Terminal Blocks Class J Fuseblocks Standard J Fuseblocks (600V) Catalog Data Dimensional Data ⁄Ω ™ -60A 1.702 3.202 2.250 .750 .750 1.500 J600 Series Catalog Symbol: Ampere Rating: Voltage Rating: Withstand Rating: Agency Information: Materials: UL Flammability: ...

Page 58

Fuseblocks, Holders and Terminal Blocks Class J Fuseblocks 101-200A 3.1" .75" 3" 2" .5" 3.06" .75" C'Bore 6.125" .34" DIA. FIGURE 6. 201-400A 4" 3" 1" 1.75" .625" 3.5" .75" C'Bore .34" 7.5" DIA. .5" FIGURE 8. 401-600A 4.99" 4" ...

Page 59

DIN-RAIL MOUNTING SCREW 8" APART (203.2mm) END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES 4.00" MAX. (101.6mm) 3.75" (±0.02) (95.3mm (±0.50) 1.88" (47.6mm) 1.19" (30.2mm) 2.38" (60.4mm) 3.29" (83.6mm) CE logo denotes compliance with ...

Page 60

Fuseblocks, Holders and Terminal Blocks Semiconductor Fuseblocks J70100 Ampere Rating: 100 Voltage Rating: Agency Information: Withstand Rating: 22 ≈ 58 Materials: UL Flammability: Dimensional Data 100A 1.702 3.202 2.250 .750 Data Sheet: 1211 56 Amps 4.702 2.250 .750 C L ...

Page 61

... Fuseblocks, Holders and Terminal Blocks Class J (Finger-Safe) Fuseholders JT(N)60030 and JT(N)60060 For use with Bussmann Class “J” fuses - (Bussmann LPJ, JKS) Catalog Numbers: Construction: Voltage Ratings: Amperage Rating: Withstand Rating: Agency Information: MOUNTING JT60030 JTN60030 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 62

... Fuseblocks, Holders and Terminal Blocks Class J (Finger-Safe) Fuseholders JT(N)600 Series fuseblocks can be dovetailed together within the same current rating to provide multiple pole block configurations. NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060. MOUNTING JT60060 JTN60060 Data Sheet: 1152 58 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann ® ...

Page 63

Fuseblocks, Holders and Terminal Blocks Class T Fuseblocks – 300V T300 Construction: Rating: ⁄Ω ™ Withstand Rating: Agency Information: CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application ...

Page 64

Fuseblocks, Holders and Terminal Blocks Class T Fuseblocks – 300V Figure 2. 61A to 100A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 2.06" 1.41" 0.84" 2.81" X 2.25" 4.78" REF. X 0.38" 0.75" Figure 4. 200A 4.87" 1.695" ...

Page 65

Fuseblocks, Holders and Terminal Blocks Class T Fuseblocks – 600V T600 Construction: Rating: ⁄Ω ™ Withstand Rating: Agency Information: CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application ...

Page 66

Fuseblocks, Holders and Terminal Blocks Class T Fuseblocks – 600V Figure 3. 61A to 100A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 1.41" (2 POLE) 0.84" 2.81" (3 POLE 2.39" 0.38" 0.75" Figure 4. ...

Page 67

Fuseblocks, Holders and Terminal Blocks Class H(K), J and R Fuseblocks Porcelain Type Fuseblocks Class H(K) and R Dimensions Agency Information: Class H and K Dimension Fuseblocks - Porcelain Type For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 68

... Amps Screw Connect* Plate Connect* Lug Data Sheet: 1105 BCCM Series Catalog Data Terminal Type Screw with Pressure Plate Quick Connect* w/Quick Connect* BCCM6033SQ BCCM6033PQ Data Sheet: 1106 64 BM Series Type M Supplementary Fuseblocks Construction: Ratings: Withstand Rating: Agency Information: Dimensional Data: ...

Page 69

... Fuseblocks, Holders and Terminal Blocks Modular Fuseholders CH Series Features: ≈ Specifications 10 ≈ For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Standards: North American Class CC North American Midget ⁄‹Ω £ ™∑ ⁄Ω ™ ∑ European 10 ≈ ≈ ≈ ...

Page 70

Fuseblocks, Holders and Terminal Blocks For ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses 3743 Add-on Fuseblocks for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses No. 3742 0.84" 1.29" 0.500" 1.125" ...

Page 71

Fuseblocks, Holders and Terminal Blocks Modular Fuseblocks CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann ...

Page 72

Fuseblocks, Holders and Terminal Blocks Box Cover Units for Plug Fuses Selection Data - Plug Fuse Box Cover Units Data Sheet: 1129 68 BOX COVER UNITS SOU, SRU, SSU, SOW, SRW, SSW, SOX, SRX, SSX, SOY, SRY, SSY, SSY-RL, SSY-L, ...

Page 73

Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Mount for 5mm ≈ 20mm Fuses HTC-45M PCB Vertical Mount CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering ...

Page 74

Dia. 3 Holes 0.469" (1.3mm) (12.0mm) 0.600" (15.2mm) 0.700" (17.8mm) 0.250" (6.4mm) Panel PC Board Data Sheet: 2118 FBI For complete specification data, ...

Page 75

Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm Fuses HTC-30M Ratings: 11mm HTC-35M Ratings: 5.5mm HTC-40M Ratings: 6.5mm HTC-55M Ratings: 0.5mm 5.5mm HTC-70M Ratings: 0.5mm 5.5mm Specifications Terminals: Molded Materials: Solderability: Agency Information: Electrical: Shock Safety: Packaging: ...

Page 76

... Specifications Terminals: Agency Information: Replacement Parts: 72 HKP-BBHH, HKP-HH and HKP-LW-HH ∑ Fuseholders with ⁄/¢ Quick- connects Electrical Ratings for HPF Series Punched Mounting Hole Drilled Mounting Hole Data Sheet: 2106 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann ® ...

Page 77

... Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm and ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fuses HTB Series Fuseholders with Knob-Type Carriers Agency Information: Electrical Data: Dimensional Data Knob Type Carrier 0.47" 1.125" (11.9mm) (28.6mm) ...

Page 78

... Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm and ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fuses HTB Series Fuseholders with Screwdriver Slotted Carriers Dimensional Data Knob Type Carrier ∑ ∑ 0.17" 1.58" (4.37mm) (40.03mm) ∑ ...

Page 79

Fuseblocks, Holders and Terminal Blocks Panel-Mounted for Indicating Type Fuses HLD Pin Indicating for ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fuses Voltage Rating: 250V, 15A Agency Information: UL Recognized, (File E14853, Guide IZLT2) 2.5" (HLD) (63.5mm) 0.69" (17.5mm) Octagonal ...

Page 80

... Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders for ⁄Ω ¢ ∑ ≈ ‡Ω • ∑ to 1⁄Ω ¢ ∑ Fuses HFB Waterproof In-Line Fuseholder for ⁄Ω ¢ ∑ ≈ 1⁄Ω ¢ ∑ Fuses Voltage Rating: Construction: ...

Page 81

... Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders HR and HM Series In-Line Fuseholders for SFE and ⁄Ω ¢ ∑ ≈ Various Length Fuses Voltage Rating: No agency listings. Electrical Ratings Dimensional Data Data Sheet: 2122 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 82

... Amps Volts Fuse Description Data Sheet: 2113 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann HPG and HPD Standard Fuseholders with Bayonet-type Knob for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File ...

Page 83

Fuseblocks, Holders and Disconnect Switches Fuseblocks, Holders and Terminal Blocks Panel-Mounted for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses HPM Standard Fuseholder with Screw-type Knob for ⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑ Fuses Agency Information: UL Recognized, (Guide ...

Page 84

... Data Sheet: 2124 Double Pole KTK-R Fuses HEY Series In-Line Fuseholders Double-Pole Voltage Rating: Data Sheet: 2126 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann ...

Page 85

Fuseblocks, Holders and Terminal Blocks For HEB Holders Only No. of Terminal Wire Size Wires per Solid Stranded Type Terminal Wire Wire For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Line Terminal No. of Terminal Wire Size Wires ...

Page 86

... Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders for Automotive Blade-Type Fuses HHC, HHD, HHF and HHG In-Line Fuseholders for ATC ® Blade-Type Fuses Voltage Rating: Current Rating: Electrical Ratings Bulk Products (Bulk Quantity - 1000 Pieces) A fuse must be properly and fully inserted into the holder to provide a solid connection ...

Page 87

Anti-Rotation Pin: Carton Quantity: Bulk Carton: Bolt-in Mounting Snap-in Mounting Catalog Code ° ° For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ≈ ⁄Ω ¢ ∑ Data Sheet: ...

Page 88

Fuseblocks, Holders and Terminal Blocks For ⁄Ω ¢ ∑ ≈ 1∑ Fuses Series 3828 Solder Terminals Fuseblock for ⁄Ω ¢ ∑ 1.88" (47.6mm) 0.63" (15.9mm) 0.19" 1.38" (4.8mm) (34.9mm) Catalog And Dimensional Data 84 4520 and 4393 ≈ Single Pole ...

Page 89

Fuseblocks, Holders and Terminal Blocks Printed Circuit Board for 5mm Diameter Fuses HTC-15M, HTC-140M PCB Fuseblock and Snap-On Cover Voltage Rating: HTC-200M PC Board Mount Fuseclip Construction: HTC-210M PC Board Mounted Fuseclip with End Stops 1A3399 Series Fuseclips with End ...

Page 90

Fuseblocks, Holders and Terminal Blocks Printed Circuit Board for ⁄Ω ¢ ∑ Diameter Fuses 1A3398 Series Fuseclips without End Stops and Straight Leads Catalog Number Clip Material 1A3398-07 Cartridge Brass 1A3398-08 Spring Bronze 1A1907 Series Fuseclips with End Stops and ...

Page 91

Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Fuseclips 1A3400 Series Fuseclips for ⁄‹Ω £ ™∑ diameter fuses with End Stops and Straight Leads Catalog Number Clip Material Finish 1A3400-09 Spring Bronze Bright Tin 20A Maximum 1A5600 Series Fuseclips for ...

Page 92

Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Fuseclips 5681 & 5682 Series Fuseclips with Mounting Holes For ⁄Ω ¢ ∑ Diameter Fuses 5672 & 5674 Series Fuseclips with Mounting Holes For ·Ω £ ™∑ Diameter Fuses 5956 & 5960 ...

Page 93

For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 94

For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 95

For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 96

Sectional Terminal Blocks For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 97

Fuseblocks, Holders and Terminal Blocks Quick Connect Terminal Blocks NTQ23-WH Ratings: Center Spacing: Number of Poles: Circuits per Foot: Wire Size: Screw Size: Mounting Options: Marking Tape: Color: Torque Rating: For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 98

... Fuseblocks, Holders and Terminal Blocks Rail Mount Fuseholders and Circuit Breakers NDNF1-WH Ratings: Number of Poles: Fuse Size: Circuit Jumper: Wire Size: Mounting Options: Marking Tape: Torque Rating: NDNF1 Colors: Fuse Pullers (Optional): 94 NDNLFD1 Ratings: Number of Poles: Fuse Size: Circuit Jumper: Wire Size: ...

Page 99

CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). ...

Page 100

Data Sheet: 1117 (Series 160, 162, 165); 1148 (Series 163) Connector to Stud Stud to Stud Data Sheet: 1117 (Series 160, 162, 165) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ...

Page 101

Fuseblocks, Holders and Terminal Blocks Power Distribution Blocks 163 Series Ampere Ratings: Voltage Ratings: Construction: Agency Information: Optional Covers: Supplied with (4) #4 thread-cutting screws assembled as shown 4.14" Textured surface for marking CPDB-1 (single pole) 2.10" CPDB-2 (two pole) ...

Page 102

Page 98 Blank (Do NOT Print) ...

Page 103

Overview for Fusible Disconnect Switches CFD30J3 CFD60J3 Catalog number 3 pole CFD30CC3 General purpose amp rating A 30 Approvals1 2 pole N/A 3 pole UL98 & IEC 4 pole UL98 & IEC Technical ratings (UL,CSA) Max operating voltage V 600 ...

Page 104

Fusible Disconnect Switches Base & DIN Rail Mounted UL Fuse Class J, CC For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 30A Switches, 600V 3 pole 4 pole CFD30J3 Selector Handles CDH3S, ...

Page 105

Handles & Shafts For 30A Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft Pistol Handles For use with shafts .20 x .20" ( NEMA IEC Type Type Color 1,3R,12 IP65 ...

Page 106

For Fusible Disconnect Switches UL Fuse Class J For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 60 100A Switches, 600V — UL General UL Fuse Maximum ...

Page 107

Accessories For 60A - 100A Fusible Disconnect Switches Terminal Lug Kit For Use On: CFD60J_ CFD100J_ BDTL24 Auxiliary Contacts Description 1 N.O. 1 N.C. CDAUX10 CDAUX01K Replacement Fuse Clip Description Removable fuse carrier CFC60J Replacement Fuse Covers Description Transparent fuse ...

Page 108

Fusible Disconnect Switches UL Fuse Class For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit FD400J3 FD600J3 FD800L3 Pistol Handles — .47 x .47" ...

Page 109

Accessories For 200A - 800A Fusible Disconnect Switches Shafts Shaft Length (inches/mm) For use on FD200J_ – FD400J_ 8.7/220 9.8/250 11.0/280 12.8/325 15.6/395 18.3/465 BDS_ 21.1/535 For use on FD600J_ – FD800J_ 9.8/250 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 Twisted Shafts ...

Page 110

Overview For Non-Fusible Disconnect Switches CDNF16 CDNF25 CDNF32 Catalog Number 3 pole CDNF16 General Purpose A 16 Amp Rating Approvals1 2 pole N/A 3 pole UL508 4 pole UL508 Technical Ratings UL,CSA Max operating voltage V 600 Max horsepower rating ...

Page 111

Overview For Non-Fusible Disconnect Switches BDNF175A BDNF200A BDNF400A Catalog Number 3 pole BDNF175A BDNF200A BDNF400 BDNF600A BDNF800A BDNF1200 BDNF1600 BDNF2000 General Purpose A 175 200 Amp Rating Approvals1 2 pole UL508 & IEC UL98 & IEC UL98 & IEC UL98 ...

Page 112

For Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 16 — 100 Amp Switches, 600V, 3 Pole CDNF16 CDNF25 CDNF32 CDNF30 CDNF60 CDNF100 Selector Handles All marked ...

Page 113

Handles & Shafts For 16A-100A Non-Fusible Disconnect Switches Base & DIN Rail Mounted Pistol Handles NEMA Type BDH104, 106 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12,4,4X IP66 1,3R,12,4,4X IP66 BDH107 Shafts Shaft Length (inches/mm) 5.9/150 CDS_P 6.7/170 10.4/265 15.8/400 19.7/500 Twisted Shafts ...

Page 114

Non-Fusible Disconnect Switches Door Mounted For a complete assembly, please select one of each: 1 switch 1 handle 16 — 100 Amp Switches, 600V, 3 Pole CDNF16D CDNF25D CDNF32D CDH8S Selector Handles CDH12S All marked both O/I ...

Page 115

Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 400 – 800 Amp switches, 600V UL general purpose amp rating 2 pole 400 BDNF600A ...

Page 116

Accessories for 400A – 800A Non-Fusible Disconnect Switches Terminal lug kits BDTL26 BDTL27 BDNF400 – BDNF600A Auxiliary contacts BDTL30 BDTL175/400 BDTL32 Terminal poles BDAUX1-6 Terminal shrouds BDZX85 Handle support bracket Allows handle to be directly BDTS_ 1 A load side ...

Page 117

Enclosed Fusible Disconnect Switches 30A – 800A 3 Pole1, 600V, 30A – 3150A UL General purpose Fuse amp rating Type 100 J 2 200 J 2 400 J 2 600 J 2 ...

Page 118

Enclosed Fusible Disconnect Switches 30A – 800A 3 Pole1, 600V, 30A – 3150A UL General purpose Fuse amp rating Type 100 200 400 600 800 Handle ratings Amperage Style NEMA range type Selector 1,3R,12 Selector 1,3R,12 30 ...

Page 119

Other Configurations for Enclosed Fusible Disconnect Switches UL general purpose Type of Switch amp rating 4 Pole1 6 Pole 30 (J fuses) Transfer Bypass Mech. interlock 4 Pole1 6 Pole 30 (CC fuses) Transfer Bypass Mech. interlock 4 Pole1 60 ...

Page 120

Other Configurations for Enclosed Fusible Disconnect Switches UL General purpose Type of Switch amp rating 4 Pole1 6 Pole 30 (J fuses) Transfer Bypass Mech. interlock 4 Pole1 6 Pole 30 (CC fuses) Transfer Bypass Mech. interlock 4 Pole1 60 ...

Page 121

Enclosed Non-Fusible Disconnect Switches 16A – 3150A ENF321-3PBJ 3 Pole, 600V, 16A – 100A — Selector handle 1 UL general purpose Catalog amp rating number 16 ENF161-3PBJ 25 ENF251-3PBJ 40 ENF321-3PBJ 60 ENF451-3PBJ 80 ENF631-3PBJ 3 Pole, 600V, 16A – ...

Page 122

Enclosed Non-Fusible Disconnect Switches 16A – 3150A ENF25P-3PY6 3 Pole, 600V, 16A – 100A — Selector handle 4X Plastic Selector handles are only NEMA rated 1, 3R general purpose Catalog amp rating number 16 ENF16P-3PBJ 25 ENF25P-3PBJ 40 ...

Page 123

Enclosed Non-Fusible Disconnect Switches 16A – 400A Other Configurations UL General purpose Type of switch amp rating 4 Pole ENF161-4PB6 6 Pole ENF161-6PB6 16 Transfer ENF161-3TB8 Bypass ENF161-3BB8 Mech. interlock ENF161-3MB6 4 Pole ENF251-4PB6 6 Pole ENF251-6PB6 25 Transfer ENF251-3TB8 ...

Page 124

Enclosed Non-Fusible Disconnect Switches 16A – 400A Other Configurations UL General purpose Type of switch amp rating 4 pole 16 6 pole Transfer Bypass Mech. interlock 4 pole 25 6 pole Transfer Bypass Mech. interlock 4 Pole 6 Pole 40 ...

Page 125

Disconnect Switches Fused, Dead Front, Disconnect Switches 15149 Series Voltage Ratings: 600Vac, 30A Agency Information: UL Recognized, file E116716 for General Industrial installations. Guide WFXV2. CSA certified, file LR37129-6 • and 3 poles. • Class J fuses. • ...

Page 126

Disconnect Switches Power Module™ —All-in-one Elevator Disconnect Bussmann (Fusible switch with shunt trip and fire safety interface to allow for single point tie in with fire alarm system.) Complies with: ® NFPA 70 (NEC ; National Electrical Code ANSI/ASME A17.1 ...

Page 127

High Speed Fuses North American Style — General Information Voltage Rating 130Vac/dc 1000 to 4000A 150Vac/dc 250Vac/dc 500Vac/dc 600Vac 700Vac/dc 800Vdc 1000Vac, 700Vdc All Bussmann North American Style fuses are certified for their rated voltage. For complete specification data, call ...

Page 128

High Speed Fuses North American Style FWA 130V Voltage Rating: 130Vac/130Vdc (130Vdc rating applies to 1000 through 2000A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics I t ...

Page 129

High Speed Fuses North American Style FWX 250V Voltage Rating: 250Vac/250Vdc (250Vdc rating on 35 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13, 35-800A Watts loss provided at rated current. Electrical Characteristics I t ...

Page 130

High Speed Fuses North American Style FWH 500V Voltage Rating: 500Vac/500Vdc (500Vdc rating applies to 35 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13, 35-1200A; CSA Component Acceptance 35-1600A Watts loss provided at rated ...

Page 131

High Speed Fuses North American Style KAC 600V Voltage Rating: 600Vac Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13,1-600A • For new installations, Bussmann recommends the 700V FWP series fuse. The 600V fuses are supplied as replacements ...

Page 132

High Speed Fuses North American Style FWP 700V Voltage Rating: 700Vac/700Vdc (700Vdc rating applies to 5 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13; CSA Component Acceptance Watts loss provided at rated current. Electrical ...

Page 133

High Speed Fuses North American Style FWJ 1000V Voltage Rating: 1000Vac/800Vdc (Ampere ratings 35-200 and 500-600 rated up to 800Vdc) Interrupting Rating: 25kA for 35-200A, 100kA for 250-600A Agency Information: UL Recognition on 35 through 600A only, Std. 248-13 Watts ...

Page 134

High Speed Fuses North American Style Fuseblocks Modular Style Bussmann offers a comprehensive line of fuse bases that pro- vide the user with design and manufacturing flexibility. Two identical half bases make up a Buss Modular fuse base. These “split” ...

Page 135

High Speed Fuses European Style Square Body — General Information Voltage Rating 690Vac 1250Vac All Bussmann European Style fuses are tested to IEC 60269, Part 4. This standard requires a test voltage which is 10% higher than the rated voltage. ...

Page 136

High Speed Fuses European Style Square Body DIN 43 653 —10-400A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 CSA Component Acceptance on Size 000 Watts loss provided ...

Page 137

High Speed Fuses European Style Square Body DIN 43 653 — 40-2000A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated ...

Page 138

High Speed Fuses European Style Square Body DIN 43 653 — 40-2000A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated ...

Page 139

High Speed Fuses European Style Square Body DIN 43 653 — 50-1400A Voltage Rating: 1250V (IEC)/1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered ...

Page 140

High Speed Fuses European Style Square Body DIN 43 653 — 50-1400A Voltage Rating: 1250V (IEC)/1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered ...

Page 141

High Speed Fuses European Style Square Body DIN 43 620 —10-315A Voltage Rating: 690V (IEC/UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Rated Current: The rated current of this fuse range has been given ...

Page 142

High Speed Fuses European Style Square Body DIN 43 620 — 40-1000A Voltage Rating: 690V (IEC)/700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Rated Current: The rated current of this fuse range has ...

Page 143

High Speed Fuses European Style Square Body Flush End Contact 25-400A Voltage Rating: 690V (IEC) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics I ...

Page 144

High Speed Fuses European Style Square Body Flush End Contact 40-2000A Voltage Rating: 690V (IEC) 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch ...

Page 145

High Speed Fuses European Style Square Body Flush End Contact —1000-4000A Voltage Rating: 690V (IEC) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom ...

Page 146

High Speed Fuses European Style Square Body Flush End Contact — 50-1400A Voltage Rating: 1250V (IEC) 1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ...

Page 147

High Speed Fuses European Style Square Body French Standard — 40-1500A Voltage Rating: 690V (IEC), 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch ...

Page 148

High Speed Fuses European Style Square Body US Standard — 40-2000A Voltage Rating: 690V (IEC), 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch ...

Page 149

High Speed Fuses European Style Square Body US Standard — 50-1400A Voltage Rating: 1250V (IEC), 1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered ...

Page 150

High Speed Fuses Indicator System Indicators Typower ZILOX fuses are available with three different indica- tor systems. Visual Indicator The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for ...

Page 151

High Speed Fuses Fuse Bases (Blocks) DIN 43 653 Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, the following fuse bases are available: Part Max. Rated Number Voltage Current 170H3003 1000V 630A 170H3004 1000V 1250A 170H3005 ...

Page 152

High Speed Fuses British Standard BS88: Part 4 Voltage Rating 240Vac/150Vdc 690Vac/450Vdc All Bussmann British Style fuses are tested to IEC 269: Part 4. This standard requires a test voltage which is 10% higher than the rated voltage. In North ...

Page 153

High Speed Fuses British Standard BS88: Part 4 690Vac/500Vdc 6-700A Interrupting Rating: 200kA RMS Symmetrical. UL Recognized, Std. 248-13, Watts loss provided at rated current. MT, MMT and additional ratings of ET and EET are available for replacement purposes on ...

Page 154

High Speed Fuses Indicator System and Fuse Bases (Blocks) Trip Indicator Trip-indicator fuselinks are available for use in parallel with the main fuselinks. They can either be attached to the associated fuselink or mounted separately in panel mounted fuse clips, ...

Page 155

... AC drives and other low power applications where 20 to 30A space premium 15A Accessories Ferrule fuses may be mounted in fuse clips, fuseholders, fuseblocks or fused switches. A variety of products are avail- able to suit most end-use requirements. Ordering Information Clearing Watts at 150V Loss ...

Page 156

High Speed Fuses Ferrule Style FWX 250Vac/250Vdc (250Vdc on 5 through 30) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 250V, Std. 248-13 & CSA Component Acceptance Watts loss provided at rated current. Electrical Characteristics ...

Page 157

High Speed Fuses Ferrule Style FWC 600Vac Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 600V, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics SEC) Rated Current Clearing Size RMS-Amps Pre-arc 6 ...

Page 158

High Speed Fuses Ferrule Style FWP 690V/700V (IEC/UL) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 700V, Std. 248-13 & CSA Component Acceptance Watts loss provided at rated current. Electrical Characteristics SEC Rated Current ...

Page 159

High Speed Fuses Ferrule Style FWJ 1000Vac Interrupting Rating: 25kA RMS Symmetrical. Agency Information: UL Recognized, 1000Vac/800Vdc, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics SEC Rated Current Size RMS-Amps Pre-arc at 1000V ...

Page 160

Page 156 BLANK (Do NOT Print) ...

Page 161

Medium Voltage Fuses and Fuse Links BBU Boric Acid Fuse-Features Construction Principle parts of the replaceable BBU fuse unit are shown in the cross sec- tion view. Main operating parts are the silver element, arcing rod, boric acid cylinder, and ...

Page 162

Medium Voltage Fuses and Fuse Links BBU Boric Acid Fuses for Use Indoors BBU17- BBU17- BBU17- BBU17-10K BBU17-12K BBU17-15K ...

Page 163

Medium Voltage Fuses and Fuse Links E-Rated Medium Voltage Fuses: CL-14 & Bolt-In Electrical Characteristics Bussmann Ampere IR Number Rating Voltage Max Sym. ECL055-10E 10E 5.5kV 63kA ECL055-15E 15E 5.5kV 63kA ECL055-20E 20E 5.5kV 63kA ECL055-25E 25E 5.5kV 63kA ECL055-30E ...

Page 164

Medium Voltage Fuses and Fuse Links E-Rated Medium Voltage Fuses: CL-14 Electrical Characteristics Bussmann Ampere IR Number Rating Voltage Max Sym. ECL155-10E 10E 15.5kV 63KA ECL155-15E 15E 15.5kV 63KA ECL155-20E 20E 15.5kV 63KA ECL155-25E 25E 15.5kV 63KA ECL155-30E 30E 15.5kV ...

Page 165

... Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection Dimensional Data C INDICATOR A Showing Fuse is Open Figure 1 Figure 2 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR, & JCR-B ...

Page 166

... Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection Specifications Buss Maximum Catalog No. Amperage Design Voltage 2400V; R-Rated; Indoor/Enclosure (See Figure 1) JCK- 2540V JCK-3R 100 3R 2540V JCK-4R 130 4R 2540V JCK-5R 150 5R 2540V JCK-6R 170 6R 2540V JCK-9R 200 9R 2540V ...

Page 167

... Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection Specifications Buss Maximum Catalog No. Amperage Design Voltage 4800V; R-Rated; Indoor/Enclosure; With Westinghouse Ampguard Hookeye (See Figure 1) JCL-A- 5080V JCL-A-3R 100 3R 5080V JCL-A-4R 130 4R 5080V JCL-A-5R 150 5R 5080V JCL-A-6R 170 6R ...

Page 168

... Medium Voltage Fuses and Fuse Links Medium Voltage for Motor Circuit Protection Table of Ratings Code Breaking kV Reference Capacity (kA) 3.6 WJON6 50 3.6 WDOH6 50 3.6 WFOH6 50 3.6 WDLSJ 50 3.6 WFLSJ 50 3.6 WDFHO 50 3.6 WFFHO 50 3.6 WKFHO 50 5.5 VFNHA 60 5.5 VKNHA 60 7.2 WFNHO 40 7.2 ...

Page 169

Medium Voltage Fuses and Fuse Links E-Rated Medium Volt for Transformers and Feeders Electrical Characteristics 5.5kV Min. Max. Part Ampere Melt Clear Number Rating MV055F1CAX5E 5A 180 2,400 MV055F1CAX7E 7A 850 8,000 MV055F1CAX10E 10A ...

Page 170

Medium Voltage Fuses and Fuse Links E-Rated Medium Volt Specifications Buss Maximum Catalog No. Amperage Design Voltage 2400V; E-Rated Fuse; Indicating JCD-⁄Ω ™ E 0.50E 2750V JCD-1E 1.00E 2750V JCD-2E 2.00E 2750V JCD-5E 5.00E 2750V 2450/5500V; E-Rated Fuse; Non-Indicating JCW-⁄Ω ...

Page 171

Medium Voltage Fuses and Fuse Links E-Rated Fuses for Trans. & Feeder Protection Specifications Buss Maximum Catalog No. Amperage Design Voltage 2400V; E-Rated; Indoor/Enclosure JCX-⁄Ω ™ E ⁄Ω ™ E 2750V JCX-1E 1E 2750V JCX-2E 2E 2750V JCX-3E 3E 2750V ...

Page 172

Medium Voltage Fuses and Fuse Links E-Rated Fuses for Trans. & Feeder Protection Specifications Buss Maximum Catalog No. Amperage Design Voltage 5500V; E-Rated; Indoor/Enclosure JCU-10E 10E 5500V JCU-15E 15E 5500V JCU-20E 20E 5500V JCU-25E 25E 5500V JCU-30E 30E 5500V JCU-40E ...

Page 173

Medium Voltage Fuses and Fuse Links Medium Voltage DIN Distribution Fuses Table of Ratings and Dimensions kV Code Ref. Current Rating ADOSJ 6.3, 16, 20, 25, 31.5, 40, WDOSJ 50, 63, 80, 100, 125 ____________________________________________________ ______________________________ WFOSJ 160, 200 ____________________________________________________________________________________________________ ...

Page 174

Medium Voltage Fuses and Fuse Links Potential Transformer Fuses “AB” & “AM” Series Code kV Reference 3.6 ABWNA 3.15, 6.3 3.6 ABCNA 3.15, 6.3, 10 5.5 ABWNA 0.5E, 1E, 2E, 3E, 5E 5.5 AMWNA 0.5E, 1.0E, 2.0E, 3.0E, 4.0E, 5.0E ...

Page 175

Medium Voltage Fuses and Fuse Links Medium Voltage, Fast Acting Fuses HVA, HVB, HVJ, HVL, HVR, HVT, HVU, HVW & HVX Non-Time Delay Ampere Ratings: Voltage Rating: 1000 to 10,000V HVA (1000 Volts) (Max. S.C. 20KW dc, 30KVA ac) Length ...

Page 176

Medium Voltage Fuses and Fuse Links Medium Voltage — BS2692-1 Fuses General Guide to the Selection of HV Fuse Links, used in oilfield switchgear. For use in the Primary Circuit of Three Phase 50 Hz Transformers Transformer kVA 3.3kV 200 ...

Page 177

Medium Voltage Fuses and Fuse Links Medium Voltage Fuse Links EEI-NEMA Type K and T Fuse Links These fuse links afford effective overcurrent protection to sys- tems and equipment. In addition to apparatus protection, they can be coordinated with other ...

Page 178

Page 174 BLANK (Do NOT Print) ...

Page 179

... Recommended .75 inch center-to-center product spacing. • Current-limiting capability • Complete system coordination capability. • Highest interrupting rating (100,000A) available for DC circuit protection of this footprint. • No venting of arc or molten metals and gases during opening. • Fuse material: Black thermoplastic, UL rated 94 V-O, 170° ...

Page 180

Telpower DC Power Protection Systems ® Telpower Miniature Fused Disconnect Switch ® TPM & TPMDS TPMDS - Telpower Miniature Fused Disconnect Switch ® TPM - Telpower Miniature Fuse - Current Limiting ® Ampere Ratings: 3-30A Voltage Rating: 80Vdc Interrupting Rating: ...

Page 181

... DC applications. • Fuse presence indication. • Fuse orientation rejection feature. • Totally enclosed module. • Spare fuseholders: Part No. 5TPH and TPSFH-A • Remote alarm. • Contact Bussmann for options on standard module (Hardware, Color, Front line connection, Mounting bezel). TPA-B ...

Page 182

... CSA Certified, Class 1422-30, File 53787 Construction: • Silver-plated brass ferrules and indicator pin on TPA 3-15 and TPA-B. Tin-plated brass on TPA 20-50 on indicator end. • Glass melamine tube. • Spare fuseholders: 5 position holder; 5TPH; 6 position holder; TPSFH-AS Dimensional Data mm inches Data Sheet: 5012 For complete specification data, call Bussmann Information Fax ~ 636 ...

Page 183

... Thermoplastic housing material U.L. rated 94V-0, 150°C. • Spare alarm and power fuse compartment. • Mounting hardware included. • Spare fuseholders: for TPS fuses (TPSFH-AS); for GMT fuses (TPSFH-T), see page 196. Dimensional Data 15800-R-200 For complete specification data, call Bussmann Information Fax ~ 636 ...

Page 184

... Data Sheet: 5021 180 Easy Fuse Replacement • Thermoplastic housing material UL rated 94V-0, 150°C. • Spare fuseholders: for TPL-B fuses (TPSFH-LB), see page 14; for GMT fuses (TPSFH-T), see page 14. • Application Note: The line connection uses a 1/4-20 bolt (metric – M6X1) that threads into the line terminal. The line terminal is designed with a float of ± ...

Page 185

Telpower ® DC Power Protection Systems Fused Disconnect Switches 15100 Fused Disconnect System For use with Telpower Fuses Type TPL. Ampere Ratings: 70-800A. Voltage Rating: 60Vdc UL Withstand Rating: 100,000A Agency Information: UL Recognized, Guide QPQY2, File E97649 Catalog Numbers ...

Page 186

Telpower ® DC Power Protection Systems ® Telpower High Current Switch TPHCS800-MAV (shown) TPHCS Telpower ® High Current Switch For use with Telpower ® Fuses Type TPL-B, TPL-C and TPH. Ampere Ratings 800A Voltage Rating: 80Vdc UL Withstand ...

Page 187

... Use with Telpower 15100, 15200, TP158HC and TPHCS .93 .42 disconnect systems. .93 .42 • For replacement of Bussmann’s UBO fuses a TPL-TA adap- .93 .42 tor kit is necessary. .93 .42 .93 .42 • Spare fuseholders: .93 .42 TPSFH-LB (for TPL-B fuses) .93 .42 TPSFH-LC (for TPL-C fuses) .93 .42 .49 .22 .49 .22 .49 ...

Page 188

... Complete system coordination capability. 2.38 1.078 • Energy savings with low watts loss, low operating tempera- 3.50 1.587 tures, and minimum I • Spare fuseholders: TPSFH-N30 (for TPN 1-30) TPSFH-N60 (for TPN 35-60) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann 0.81" (20.6mm) 1.00" ...

Page 189

Telpower ® DC Power Protection Systems Indicating Fuse & Holder 70 Series Indicating Type Fuse Voltage Rating: 125Vac; 300Vdc Agency Information: UL Recognized, Guide JDYX2, File E19180 Bellcore 70 Series Telpower (125Vac, 300Vdc) Catalog Ampere Voltage Rating Color Number Rating ...

Page 190

... UL Recognized, Guide JFHR2, File E56412 Materials: Body: Thermoplastic, UL 94VO flammability rating Terminals: Tin-plated Beryllium copper Carton Qty. and Weight: 100 Fuses per carton; 0.33 lbs. (150g) Fuseholders: Catalog No. HLT, HLS, and PCT Spare Fuseholder: TPSFH-T Catalog Numbers Catalog Color Catalog Symbol ...

Page 191

Telpower Telecommunications Protection ® DC Power Protection Systems ® Telpower Specialty Fuses Dimensional Data 2.685" (68.20mm) 81 Type Description: Cylindrical, fast acting, non-indicating high current companion to the 80 Type. UL Recognized, Guide JDYX2, File E19180. Catalog Data Catalog Ampere ...

Page 192

Telecommunications Protection ® Telpower Specialty Fuses Dimensional Data 74 Type Description: .281 1.25 cylindrical fuse, fast acting. Designed to comply with Lucent specification KS23753. High current companion to 70 Type Fuse. Catalog Data Catalog Ampere Voltage Rating Lucent Comcode Symbol ...

Page 193

Pg 189 Do not Print ...

Page 194

British, European, & Canadian Standard Industrial Fuses CSA Type P and Type D Fuses CDS, CDN & PON Voltage Ratings: 250V (CDN & PON) & 600V (CDS) Interrupting Rating: 10kA minimum Agency Information: CSA Certified to C22.2 No. 59.1 Time-Delay ...

Page 195

British, European, & Canadian Standard Industrial Fuses HRC Form II Class C Fuses CGL Tron HRC Form II Class C Fuses ® Ampere Ratings 600A. Voltage Rating: 600Vac, 250Vdc (1-30A) Interrupting Rating: 200,000A (40,000A dc) Current Limiting Agency ...

Page 196

... Ampere Ratings: 1-30A Voltage Rating: 600Vac; 250Vdc Interrupting Rating: 200,000A RMS Symmetrical Agency Information: CSA C22.2 No. 106-M92 • Provides both overload and short- circuit protection to HRCI requirements. • Offset blades for bolt-on mounting. • CIF21 fuse fits the Bussmann-Camaster Fuseholder. Catalog Current Type ...

Page 197

British, European, & Canadian Standard Industrial Fuses HRCI-J Fast Acting Fuses CJ HRCI-J Fast Acting Fuses Voltage Rating: 600Vac or less, 250Vdc Construction: Ceramic Body Fuse Interrupting Rating: 200,000A I.R. Agency Information: CSA C22.2 No. 106 M92; Designed to BS88:2, ...

Page 198

... Recommended Fuseholders Fuse Fuseholder 1-30A CM30CF 35-60A CM60CF 80-100A CM100CF Data Sheet: 4130 194 Dimensional Data D K (The CIL14 has a rejection hole, not a slot as shown above.) Dimensions in Inches and (mm Max ...

Page 199

British, European, & Canadian Standard Industrial Fuses HRC Form II Current Limiting Fuses HRC Form II Current Limiting Fuses Voltage Rating: 600Vac or less, 250Vdc Construction: Ceramic Body Interrupting Rating: 200,000A RMS Symmetrical Agency Information: CSA C22.2 No.106M1992; BS88:2, IEC269:2 ...

Page 200

... Recommended Fuseholders NSD 32NNSF ESD 63ENSF CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. ...

Related keywords