CK2125100M-T Taiyo Yuden, CK2125100M-T Datasheet - Page 11

INDUCTOR 10UH MULTILAYER 0805

CK2125100M-T

Manufacturer Part Number
CK2125100M-T
Description
INDUCTOR 10UH MULTILAYER 0805
Manufacturer
Taiyo Yuden
Series
CKr
Datasheet

Specifications of CK2125100M-T

Inductance
10µH
Current
60mA
Tolerance
±20%
Dc Resistance (dcr)
650 mOhm Max
Q @ Freq
20 @ 2MHz
Self Resonant Freq
24MHz
Package / Case
0805 (2012 Metric)
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 85°C
Frequency - Test
2MHz
Applications
EMI Filter
Lead Free Status / RoHS Status
Lead free by exemption / RoHS Compliant
Shielding
-
Current - Saturation
-
Current - Temperature Rise
-
Other names
587-1691-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CK2125100M-T
Manufacturer:
Taiyo Yuden
Quantity:
30 056
Part Number:
CK2125100M-T
Manufacturer:
TAIYO YUDEN
Quantity:
66 000
Part Number:
CK2125100M-T
Quantity:
8 150
Part Number:
CK2125100M-T
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Multilayer chip inductors and beads
14. Damp Heat
15. Loading under
16. Loading at High
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20 ± 2℃ of temperature, 60 to 70% relative hu-
midity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
(Steady state)
RELIABILITY DATA
Temperature
Damp Heat
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
Appearance :No significant abnormality.
Impedance change:Within ±30%
BK0603 BK1005 BK1608 BK2125
BK2010 BK3216
ARRAY
BKP0603 BKP1005 BKP1608 BKP2125 CK1608 CK2125 CKP2520 LK1005
Specified Value
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change:
Within ±20%
Q change:
Within ±30%
No
mechanical
damage.
Inductance
change :
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±30%
No mechani-
cal damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±10%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q
change:
Within
±30%
LK1608
No
mechanical
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
No
mechanical
damage.
Induc-
tance
change:
Within
±20%
Q
change:
Within
±30%
±30%
LK2125
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
No mechanical damage.
Inductance change:Within ±10%
Q change:Within ±20%
HK0603
HK1005
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
HK1608
HK2125 HKQ0603S AQ105
(Note 1)
measurement shall be made after 48 ± 2 hrs of
recovery under the standard condition.
BBK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series:
Temperature:40±2℃ (LK、 CK 、 CKPSeries)
Humidity:90 to 95%RH
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
BK Series:
Temperature:125±3℃
Applied current:Rated current
Duration:500
Recovery:2 to 3 hrs of recovery under the
standard condition after the removal from test
chamber. ( See Note 1)
LK、 CK、 CKP、 HK、 HKQ、 AQ Series、 BK Series
P type:
Temperature:85±2℃ (LK、 CK 、 CKPSeries)
temperature range -55 to +85℃)
Applied current:Rated current
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the
standard condition after the test. ( See Note 1)
:85±3℃ (BK Series P type)
:85±2℃ (HK1608, 2125)
:85±2℃ (HK1005, AQ105 operating
:125±2℃ (HK0603, HK1005, HKQ0603S,
AQ105 operating temperature range -55 to +125℃)
Test Methods and Remarks
:60±2℃ (HK、 HKQ、 AQ Series)
:60±2℃ (HK、 HKQ、 AQ Series)
+24
−0
+24
−0
+24
−0
hrs
hrs
hrs
4/4
253
5

Related parts for CK2125100M-T