MDA-30-R Cooper/Bussmann, MDA-30-R Datasheet

FUSE 30A 250V T-LAG CER

MDA-30-R

Manufacturer Part Number
MDA-30-R
Description
FUSE 30A 250V T-LAG CER
Manufacturer
Cooper/Bussmann
Series
MDAr
Type
Time Lagr
Datasheets

Specifications of MDA-30-R

Fuse Type
Slow Blow, Time Lag
Voltage - Rated
250VAC, 125VDC
Current
30A
Package / Case
Cylindrical, 3AG, 1/4" x 1 1/4", 6x32mm
Size / Dimension
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Mounting Type
Holder
Dc Cold Resistance
0.002 Ohm
Melting I²t
1096.7
Voltage Rating Vac
250V
Voltage Rating Vdc
125V
Fuse Current
30A
Breaking Capacity
1.5kA @ 250VAC / 10kA @ 125VAC
Fuse Size Metric
6.35mm X 32mm
Fuse Size Imperial
1/4 X 1.1/4"
Svhc
No
Application
Cylinder
Brand/series
MDA Series
Current, Rating
30 A
Dimensions
0.25x1.25 "
Material, Body
Ceramic
Primary Type
Cylinder
Resistance, Dc
0.00243 Ohms
Size
3AG
Termination
Cartridge
Voltage, Rating
250/125 VAC/VDC
Fuse Size Code
3AG
Blow Characteristic
Time Delay
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Lead Free Status / Rohs Status
RoHS Compliant part
Description
• Time Delay, ceramic tube
• Optional leaded version available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Approvals
• UL Listed Card: MDA 2/10 - 20A (Guide JDYX,
• UL Recognized Card: MDA 25 - 30A (Guide JDYX2,
• CSA Certification Card: MDA 2/10 - 15
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Ordering
• Specify product code, option code and packaging code
* Interrupting Ratings (Measured at 70% - 80% power factor on AC. The interrupting ratings for 25Amp, 30Amp were measured at 90% - 100% power factor on AC)
** DC Cold Resistance (Measured at ≤10% of rated current)
† Typical Melting I
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
Product
Code
MDA-1/4
MDA-1/2
MDA-3/4
MDA-1
MDA-1-1/2
MDA-2
MDA-2-1/2
MDA-3
MDA-4
MDA-5
MDA-6
MDA-7
MDA-8
MDA-10
MDA-15
MDA-20
MDA-25
MDA-30
Rated Current
File E19180)
File E19180)
(Class No. 1422-01)
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 207,
(HI Shock)
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
1/4 - 30A
ELECTRICAL CHARACTERISTICS
2
t (A
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
2
Sec) (I
AC
Amp Rating
Voltage
Rating
2
t was measured at listed interrupting rating and rated voltage)
100%
135%
200%
125V
125V
125V
DC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1500A
1500A
1500A
120 Seconds Max.
250V
100A
100A
200A
200A
200A
200A
200A
200A
200A
200A
750A
AC Interrupting
35A
35A
35A
35A
60 Minutes Max.
Opening Time
Rating*
None
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
125V
SPECIFICATIONS
DC Interrupting
10000A
10000A
10000A
Rating
MDA Series, Time Delay, Ceramic Tube
125V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Dimensions (
Drawing Not to Scale
Typical DC Cold
Resistance**
mm
0.06685
0.02355
0.01850
0.01475
0.01230
0.00858
0.00543
0.00405
0.00309
0.00243
(ohms)
0.8555
0.2585
0.1645
0.0507
0.0346
in
9.325
1.925
0.560
)
1/4" x 1-1/4" Fuses
Melting I
Typical
1491.3
134.0
345.9
534.3
580.3
944.0
206.2
439.5
667.9
997.0
0.68
11.1
25.0
64.0
28.9
40.9
AC
2.3
7.8
2
t†
Voltage
Typical
Drop‡
0.691
0.623
0.213
0.182
0.162
0.145
0.141
0.137
0.134
0.107
0.095
0.105
0.110
4.00
1.42
1.31
1.03
N/A

Related parts for MDA-30-R

MDA-30-R Summary of contents

Page 1

... Rated Current Amp Rating 100% 1/4 - 30A 135% 200% Approvals • UL Listed Card: MDA 2/10 - 20A (Guide JDYX, File E19180) • UL Recognized Card: MDA 25 - 30A (Guide JDYX2, File E19180) • CSA Certification Card: MDA 2/ (Class No. 1422-01) Environmental Data • Shock: 1/100A and 8/10A – MIL-STD-202, Method 213, Test Condition I ...

Page 2

... Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. MDA Series, Time Delay, Ceramic Tube TIME CURRENT CURVE CURRENT IN AMPERES ...

Related keywords