FNQ-R-30 Cooper/Bussmann, FNQ-R-30 Datasheet

FUSE 30A 600VAC T-LAG CC TYPE

FNQ-R-30

Manufacturer Part Number
FNQ-R-30
Description
FUSE 30A 600VAC T-LAG CC TYPE
Manufacturer
Cooper/Bussmann
Series
CC-TRON® FNQ-Rr
Type
Time Lagr
Datasheets

Specifications of FNQ-R-30

Fuse Type
Slow Blow, Time Lag
Voltage - Rated
600VAC
Current
30A
Package / Case
Cylindrical, 5AG, Midget, 10x38mm
Size / Dimension
0.406" Dia x 1.500" L (10.30mm x 38.10mm)
Mounting Type
Holder
Voltage Rating Vdc
300V
Voltage Rating Vac
600V
Fuse Current
30A
Blow Characteristic
Time Delay
Fuse Body Material
Fiber
Fuse Size Code
5AG
Fuse Size Imperial
13/32 X 1.1/2"
Brand/series
CC-Tron®/FNQ-R Series
Class
Class CC
Current, Rating
30 A
Current, Ratings
30 A
Diameter
0.41 +⁄-0.005 in.
Dimensions
0.41x1.5 "
Length
1.5 in. +⁄-0.031 in.
Material, Body
Melamine
Primary Type
Cylinder
Termination
Cartridge
Voltage, Rating
600 VAC
Physical Size
13⁄32" × 11⁄2"
Ampere Rating
1⁄4 to 30 A
Interrupt Rating
200,000 A RMS Sym.
Voltage Rating
600 VAC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Operating Temperature
-
Color
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Other names
283-2482

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FNQ-R-30
Manufacturer:
Cooper/Bussmann
Quantity:
135
Catalog Symbol: FNQ-R
Time-Delay
Application: Circuit Transformer Protection
Ampere Rating: ⁄Ω ¢ to 30A
Voltage Rating: 600Vac (or less) †
Interrupting Rating: 200,000A RMS Sym. (UL)
Agency Information:
UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273
CSA Certified, Class CC CSA, Class 1422-01,
†12-30A is 300Vdc and 10k AIR.
Electrical Ratings (Catalog Symbol and Amperes)
FNQ-R-⁄Ω ¢
FNQ-R-‹Ω ¡ º
FNQ-R-›Ω ¡ º
FNQ-R-⁄Ω ™
FNQ-R-flΩ ¡ º
FNQ-R-‹Ω ¢
FNQ-R-°Ω ¡ º
FNQ-R-1
FNQ-R-1⁄Ω •
FNQ-R-1⁄Ω ¢
Carton Quantity and Weight
Ampere
Ratings
⁄Ω ¢ -30
*Weight per carton
CC-TRON
Time-Delay Fuses
⁄‹Ω £ ™∑ ≈ 1⁄Ω ™ ∑, 600 Volt, ⁄Ω ¢ to 30 Amps
11-20-02
File 53787–HRC-MISC
SB02450
FNQ-R-1‹Ω ¡ º
FNQ-R-1›Ω ¡ º
FNQ-R-1⁄Ω ™
FNQ-R-1flΩ ¡ º
FNQ-R-1°Ω ¡ º
FNQ-R-2
FNQ-R-2⁄Ω ¢
FNQ-R-2⁄Ω ™
FNQ-R-2°Ω ¡ º
FNQ-R-3
Carton
Qty.
10
®
FNQ-R-3¤Ω ¡ º
FNQ-R-3⁄Ω ™
FNQ-R-4
FNQ-R-4⁄Ω ™
FNQ-R-5
FNQ-R-5flΩ ¡ º
FNQ-R-6
FNQ-R-6⁄Ω ¢
FNQ-R-7
FNQ-R-7⁄Ω ™
Dimensional Data
Lbs.
.200
Weight*
( 0.031)
(38.1mm)
1.5"
.41"
( 0.005)
(10.3mm)
FNQ-R-8
FNQ-R-9
FNQ-R-10
FNQ-R-12
FNQ-R-15
FNQ-R-17⁄Ω ™
FNQ-R-20
FNQ-R-25
FNQ-R-30
.091
Kg.
General Information:
• The Bussmann CC-TRON
• Current-limitation protects down stream components
• High inrush time-delay. Control circuit transformers can
• Melamine tube. Nickel-plated brass endcaps.
Maximum Acceptable Rating of Overcurrent Device*
Less than 2A
2A to less than 9A
9A or more
**300% for other than motor control applications.
*UL 508A Table 42.1.
Rated Primary
minimum value of 12 seconds at 200% for Class CC fuses.
the needs of control circuit transformer protection.
against damaging thermal and magnetic effects of short-
circuit currents.
experience inrush currents up to 85 times their full-load
current rating. FNQ-R fuses can be sized according to
NEC and UL requirements and still allow the high inrush
currents, with significantly more time-delay than the UL
(Amperes)
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
Current
®
Protective Device Expressed As A
(FNQ-R) was designed to meet
Maximum Rating of Overcurrent
Percent of Transformer Primary
Current Rating
500**
167
125
Bussmann
FNQ-R
Data Sheet: 1014
Form No. FNQ-R
Page 1 of 2
®

Related parts for FNQ-R-30

FNQ-R-30 Summary of contents

Page 1

... CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. FNQ-R-8 FNQ-R-9 FNQ-R-10 FNQ-R-12 FNQ-R-15 FNQ-R-17⁄Ω ™ FNQ-R-20 FNQ-R-25 FNQ-R-30 — Weight* Kg. .091 Bussmann ® FNQ-R (FNQ-R) was designed to meet ® Maximum Rating of Overcurrent ...

Page 2

... Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 11-20-02 SB02450 Time-Current Characteristics–Average Melt AMPERE RATING 1000 100 .01 Bussmann ® FNQ-R CURRENT IN AMPERES Form No. FNQ-R Page Data Sheet: 1014 ...