SC-25 Cooper/Bussmann, SC-25 Datasheet

FUSE 25A 480V T-LAG SC

SC-25

Manufacturer Part Number
SC-25
Description
FUSE 25A 480V T-LAG SC
Manufacturer
Cooper/Bussmann
Series
SCr
Datasheet

Specifications of SC-25

Fuse Type
Slow Blow, Time Lag
Voltage - Rated
480VAC, 300VDC
Current
25A
Package / Case
Cylindrical
Size / Dimension
0.406" Dia x 1.620" L (10.30mm x 41.15mm)
Mounting Type
Holder
Voltage Rating Vdc
300V
Voltage Rating Vac
480V
Fuse Current
25A
Blow Characteristic
Time Delay
Fuse Size Imperial
0.41 X 1.62"
Length
41.28mm
Fuse Terminals
Ferrule
Diameter
0.406mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Catalog Symbol:
Current-Limiting
Ampere Rating: ⁄Ω ™ to 60A (fast-acting),
7 to 60A (time-delay)
Voltage Ratings:
SC ⁄Ω ™ to 20
SC 25 to 60
Interrupting Rating: 100,000A RMS Sym. AC, 10,000A dc
Agency Information:
UL Listed, Std. 248-5, Class G, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.5, Class 1422-01, File 53787
Catalog Numbers
SC-⁄Ω ™
SC-1
SC-1⁄Ω ™
SC-2
SC-2⁄Ω ™
SC-3
SC-4
SC-5
Carton Quantity and Weight
Catalog
Number
⁄Ω ™ –15
20
25–30
35–60
†Weight per carton.
Time-Delay Fuses
Class G – 600 Volt, ⁄Ω ™ - 20 Amps
4-01-04
SB04105
Carton
Qty.
600Vac, 170Vdc
480Vac, 300Vdc
480 Volt, 25 - 60 Amps
4
4
2
2
SC
SC-6
SC-7
SC-8
SC-9
SC-10
SC-12
SC-15
SC-20
0.060
0.064
0.040
0.075
Lbs.
Weight†
SC-25
SC-30
SC-35
SC-40
SC-45
SC-50
SC-60
0.0272
0.029
0.018
0.0340
Kg.
Fuse (Amps)
SC-⁄Ω ™ to 15
SC-20
SC-25 to 30
SC-35 to 60
General Information:
• Compact branch-circuit units with high interrupting rating
• With 600V rating, they can be used in 120/208, 120/240
• Length variations relative to case size make the “rejection”
• In general, SC fuses are about ⁄Ω £ the size of the 600V NEC
• SC fuses with ampere ratings above 6A have a
Dimensional Data
and current-limitation.
and 277/480V circuits.
type fuses.
fuse type.
degree of overload time-delay which permits them to pass
temporary overloads. At 200% load, they have a minimum
opening time of 12 seconds.
Bussmann Application Engineering at 636-527-1270 for more information.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
(Length)
A
.41"
(10.3mm)
See Data Sheets listed below
Class G fuses
Recommended fuseblocks/fuseholders for
• Open fuseblocks - 1106
• In-line fuseholders - 1123, 1124
1.31∑
1.41∑
1.62∑
2.25∑
A
Bussmann
Data Sheet: 1024
Form No. SC
Page 1 of 3
SC
®

Related parts for SC-25

SC-25 Summary of contents

Page 1

... A (Length) .41" (10.3mm) Fuse (Amps) SC-⁄Ω ™ SC-20 SC- SC- General Information: • Compact branch-circuit units with high interrupting rating and current-limitation. • With 600V rating, they can be used in 120/208, 120/240 and 277/480V circuits. • Length variations relative to case size make the “rejection” ...

Page 2

... Time-Delay Fuses Class G – 600 Volt, ⁄Ω ™ Amps 480 Volt Amps Peak Let-Through Curves 10,000 1,000 A 100 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 4-01-04 SB04105 Bussmann B ® Form No. SC Page Data Sheet: 1024 ...

Page 3

... Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con- tained in this bulletin ...

Related keywords