50LET Cooper/Bussmann, 50LET Datasheet

FUSE 50A 240V BRITISH

50LET

Manufacturer Part Number
50LET
Description
FUSE 50A 240V BRITISH
Manufacturer
Cooper/Bussmann
Series
LETr
Datasheet

Specifications of 50LET

Fuse Type
Fast Acting
Voltage - Rated
240VAC
Current
50A
Package / Case
Bolt Mount
Size / Dimension
0.697" Dia x 2.205" L (17.70mm x 56.00mm)
Mounting Type
Bolt Mount
Melting I²t
1400
Voltage Rating Vdc
150V
Voltage Rating Vac
240V
Fuse Current
50A
Length/height, External
58.4mm
Voltage Ac
240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
50LET
Manufacturer:
BUSSMANN
Quantity:
5 000
Part Number:
50LET
Manufacturer:
BUSSMANN
Quantity:
24
Part Number:
50LET
Manufacturer:
Cooper Bussmann
Quantity:
5 000
“F” Range
This is a superior design of fuses in the same physical
package as the “T” range.
Equivalent Ratings
This table shows the suggested equivalent ratings to
replace a “T” with an “F”.
Because of the new design technology it has been possible
to obtain the equivalent energy let-through I
amp rated fuse hence reducing the possibility of premature
operation.
This table gives a range of suggested acceptable new “F”
type to replace the earlier “T” type.
To upgrade your protection to the new “F” series select a
fuse rating within the range shown that suits your circuit
inrush requirements. You will still have the same or better
protection of your semiconductor devices.
It should be remembered that to protect devices we must
consider the energy let-through of the selected fuse. The
label amp rating will relate to the full load current and the
circuit inrush amps.
The suggested replacements are based on:
This gives enhanced reliability due to the use of a higher
current rated fuse which avoids nuisance operation and still
gives improved short-circuit protection.
84
The Edison British Style semiconductor protection fuses
include a 660VAC line utilizing new filler technology. These
new fuses have greatly reduced peak let-through current
and energy under fault conditions and hence extend fuse
protection capability. They can be recognized by the letter
“F” in their catalog number. Application and technical data
for these 660VAC “F” fuses and the original line of 240VAC
British “T” type fuses are presented on the following pages.
a. Similar surge withstand to normal circuit overloads.
b. Lower total I
2
t let-through.
2
t with a higher
Replacement Table — “T” to “F” (660V)
Earlier
“T” Range
6CT
10CT
12CT
16CT
20CT
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
65EET
75EET
90EET
110EET
140EET
160EET
160MT
180MT
200MT
250MT
280MT
315MT
355MT
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT
SEMICONDUCTOR PROTECTION FUSES
New “F” Range
Lowest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
35FE
40FE
45FE
63FE
63FE
80FE
140FEE
160FEE
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350MT
180FM
200FM
225FM
280FM
315FM
350FM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM
BRITISH STYLE–
Highest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
100FEE
120FEE
140FEE
160FEE
180FEE
200FEE
180FM
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350FM
180FM
200FM
225FM
280FM
315FM
350FM
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM

Related parts for 50LET

50LET Summary of contents

Page 1

... British “T” type fuses are presented on the following pages. “F” Range This is a superior design of fuses in the same physical package as the “T” range. Equivalent Ratings This table shows the suggested equivalent ratings to replace a “ ...

Page 2

... EET FEE 2.76" 70.0mm FM 3.15"-3.35" 80-85mm FMM 3.15"-3.35" 80-85mm • Interrupting rating 200kA RMS Symmetrical. • These fuses meet the requirements Part 4 and IEC 269-4 • Consult Edison for UL Recognition information SEMICONDUCTOR PROTECTION FUSES SEC) Part Clearing Clearing Number ...

Page 3

... 10 17 10LET 3 12LET 16LET 15 70 140 25LET 18 120 250 32LET 32 200 450 35LET 50 320 600 50LET 100 500 1400 63LET 180 1100 2200 80LET 300 1900 3800 100LET 600 3800 7500 125LET 600 3800 7500 160LET 1100 7000 18000 180LET 1600 ...

Page 4

... Type 74.6 64.3 LCT & 63.5 LET 56 41.8 FEE & EET 113 80-85 LMT 84 59 FMM 113 80-85 LMMT & LCT FM & LMT SEMICONDUCTOR PROTECTION FUSES 54.8 8.7 8.7 28 8.4 8.7 48 17.7 19.1 26.2 17.7 19 41 FE, ET & LET BRITISH STYLE– ...

Page 5

... CURRENT IN AMPERES 660V Time-Current Curves FC (6-20A) FE (35-100A) FM (180-350A) 88 SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 660V Time-Current Curves FEE (100-200A) FMM (400-700A CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING ...

Page 6

... CURRENT IN AMPERES 240V Time-Current Curves LCT (6-20A) LET (25-180A) LMMT (400-900A) SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 240V Time-Current Curves LMT (160-450A .01 .004 CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING 89 ...

Page 7

Indicator System Trip-Indicators Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL1. A push-on adapter and microswitch attachment is ...