R5F21256SNFP#U0 Renesas Electronics America, R5F21256SNFP#U0 Datasheet - Page 270

IC R8C MCU FLASH 32K 52LQFP

R5F21256SNFP#U0

Manufacturer Part Number
R5F21256SNFP#U0
Description
IC R8C MCU FLASH 32K 52LQFP
Manufacturer
Renesas Electronics America
Series
R8C/2x/25r
Datasheets

Specifications of R5F21256SNFP#U0

Core Processor
R8C
Core Size
16/32-Bit
Speed
20MHz
Connectivity
I²C, LIN, SIO, SSU, UART/USART
Peripherals
POR, Voltage Detect, WDT
Number Of I /o
41
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
52-LQFP
For Use With
R0K521256S000BE - KIT EVAL STARTER FOR R8C/25
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
R5F21256SNFP#U0R5F21256SNFP
Manufacturer:
RENESAS
Quantity:
1 000
Company:
Part Number:
R5F21256SNFP#U0R5F21256SNFP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
R5F21256SNFP#U0R5F21256SNFP
Manufacturer:
RENESAS
Quantity:
17 358
Company:
Part Number:
R5F21256SNFP#U0R5F21256SNFP#ES
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
R5F21256SNFP#U0
Manufacturer:
REA
Quantity:
748
Rev.2.00 Oct 17, 2005
REJ09B0001-0200
Table 5.2.1 Interrupt Priority Levels
Chapter 5
5.2.3 ILVL2 to ILVL0 bis, IPL
ILVL2–ILVL0
Interrupt priority levels can be set using bits ILVL2 to ILVL0.
Table 5.2.1 shows how interrupt priority levels are set. Table 5.2.2 shows interrupt enable levels in
relation to IPL.
The following lists the conditions under which an interrupt request is acknowledged:
• I flag
• IR bit
• Interrupt priority level
The I flag, bits ILVL2 to ILVL0, and IPL are independent of each other, and they do not affect each other.
When the IPL or the interrupt priority level of an interrupt is changed, the altered level is reflected in
interrupt handling with the following timing:
• If the IPL is changed by an REIT instruction, the new level takes effect beginning with the instruction
• If the IPL is changed by a POPC, LDC, or LDIPL instruction, the new level takes effect beginning with
• If the interrupt priority level of a particular interrupt is changed by an instruction such as MOV, the
new level takes effect beginning with the instruction that is executed two or three clock cycles after the
that is executed two clock cycles after the last clock cycle of the REIT instruction.
the instruction that is executed three clock cycles after the last clock cycle of the instruction used.
last clock cycle of the instruction used.
101
000
001
010
011
100
110
111
2
2
2
2
2
2
2
2
Interrupts
Level 0 (interrupt disabled)
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
page 250 of 263
Interrupt Priority
Level
= 1
= 1
> IPL
Priority
High
Low
Table 5.2.2 Interrupt Priority Levels Enabled by IPL
010
101
110
111
000
001
011
100
IPL
2
2
2
2
2
2
2
2
Interrupt levels 5 and above are enabled.
Interrupt levels 1 and above are enabled.
Interrupt levels 2 and above are enabled.
Interrupt levels 3 and above are enabled.
Interrupt levels 4 and above are enabled.
Interrupt levels 6 and above are enabled.
Interrupt levels 7 and above are enabled.
All maskable interrupts are disabled.
Enabled interrupt priority
levels
5.2 Interrupt Control

Related parts for R5F21256SNFP#U0