C8051F046-GQ Silicon Laboratories Inc, C8051F046-GQ Datasheet - Page 228

IC 8051 MCU 32K FLASH 100TQFP

C8051F046-GQ

Manufacturer Part Number
C8051F046-GQ
Description
IC 8051 MCU 32K FLASH 100TQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F04xr
Datasheets

Specifications of C8051F046-GQ

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
CAN, EBI/EMI, SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
64
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
4.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 13x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Processor Series
C8051F0x
Core
8051
Data Bus Width
8 bit
Data Ram Size
4.25 KB
Interface Type
CAN, SMBus, SPI, UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
64
Number Of Timers
5
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F040DK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 13 Channel
On-chip Dac
12 bit, 2 Channel
Package
100TQFP
Device Core
8051
Family Name
C8051F04x
Maximum Speed
25 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
336-1211

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F046-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F046-GQR
Manufacturer:
AMAZING
Quantity:
67 000
Part Number:
C8051F046-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F040/1/2/3/4/5/6/7
18.1. Bosch CAN Controller Operation
The CAN Controller featured in the C8051F04x family of devices is a full implementation of Bosch’s full
CAN module and fully complies with CAN specification 2.0B. A block diagram of the CAN controller is
shown in Figure 18.2. The CAN Core provides shifting (CANTX and CANRX), serial/parallel conversion of
messages, and other protocol related tasks such as transmission of data and acceptance filtering. The
message RAM stores 32 message objects which can be received or transmitted on a CAN network. The
CAN registers and message handler provide an interface for data transfer and notification between the
CAN controller and the CIP-51.
The function and use of the CAN Controller is detailed in the Bosch CAN User’s Guide. The User’s Guide
should be used as a reference to configure and use the CAN controller. This Silicon Labs data sheet
describes how to access the CAN controller.
The CAN Controller is typically initialized using the following steps:
The CAN Control Register (CAN0CN), CAN Test Register (CAN0TST), and CAN Status Register
(CAN0STA) in the CAN controller can be accessed directly or indirectly via CIP-51 SFR’s. All other CAN
registers must be accessed via an indirect indexing method described in
CAN0ADR, CAN0DATH, and CANDATL to Access CAN Registers” on page
228
Step 1. Set the SFRPAGE register to CAN0_PAGE.
Step 2. Set the INIT the CCE bits to ‘1’ in the CAN0CN Register. See the CAN User’s Guide for bit
Step 3. Set timing parameters in the Bit Timing Register and the BRP Extension Register.
Step 4. Initialize each message object or set it’s MsgVal bit to NOT VALID.
Step 5. Reset the INIT bit to ‘0’.
definitions.
CANTX
TX
(32 Message Objects)
Figure 18.2. CAN Controller Diagram
Message RAM
Core
CAN
Message Handler
CANRX
RX
Rev. 1.5
CAN Controller
REGISTERS
Prescaler
BRP
Interrupt
CAN_CLK
(f
sys
)
C8051F04x
232.
Section “18.2.5. Using
CIP-51
C
S
Y
S
L
K
R
's
S
F
MCU