ATMEGA324PA-PU Atmel, ATMEGA324PA-PU Datasheet - Page 322

MCU AVR 32KB FLASH 40PDIP

ATMEGA324PA-PU

Manufacturer Part Number
ATMEGA324PA-PU
Description
MCU AVR 32KB FLASH 40PDIP
Manufacturer
Atmel
Series
AVR® ATmegar

Specifications of ATMEGA324PA-PU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
32KB (16K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
40-DIP (0.600", 15.24mm)
Controller Family/series
AVR MEGA
No. Of I/o's
32
Eeprom Memory Size
1KB
Ram Memory Size
2KB
Cpu Speed
20MHz
Rohs Compliant
Yes
For Use With
ATSTK600 - DEV KIT FOR AVR/AVR32
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
26.10.11 Flash Data Byte Register
8272A–AVR–01/10
Figure 26-16. State Machine Sequence for Changing/Reading the Data Word
The Flash Data Byte Register provides an efficient way to load the entire Flash page buffer
before executing Page Write, or to read out/verify the content of the Flash. A state machine sets
up the control signals to the Flash and senses the strobe signals from the Flash, thus only the
data words need to be shifted in/out.
The Flash Data Byte Register actually consists of the 8-bit scan chain and a 8-bit temporary reg-
ister. During page load, the Update-DR state copies the content of the scan chain over to the
temporary register and initiates a write sequence that within 11 TCK cycles loads the content of
the temporary register into the Flash page buffer. The AVR automatically alternates between
writing the low and the high byte for each new Update-DR state, starting with the low byte for the
first Update-DR encountered after entering the PROG_PAGELOAD command. The Program
Counter is pre-incremented before writing the low byte, except for the first written byte. This
ensures that the first data is written to the address set up by PROG_COMMANDS, and loading
the last location in the page buffer does not make the Program Counter increment into the next
page.
During Page Read, the content of the selected Flash byte is captured into the Flash Data Byte
Register during the Capture-DR state. The AVR automatically alternates between reading the
low and the high byte for each new Capture-DR state, starting with the low byte for the first Cap-
164A/164PA/324A/324PA/644A/644PA/1284/1284P
1
0
Test-Logic-Reset
Run-Test/Idle
0
1
1
0
Select-DR Scan
Capture-DR
Update-DR
Pause-DR
Exit1-DR
Exit2-DR
Shift-DR
1
0
0
1
0
1
1
0
1
1
0
0
1
0
Select-IR Scan
Capture-IR
Update-IR
Pause-IR
Exit1-IR
Exit2-IR
Shift-IR
1
0
0
1
0
1
1
0
1
1
0
0
322