ATMEGA644A-PU Atmel, ATMEGA644A-PU Datasheet - Page 307

IC MCU AVR 64K FLASH 40PDIP

ATMEGA644A-PU

Manufacturer Part Number
ATMEGA644A-PU
Description
IC MCU AVR 64K FLASH 40PDIP
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA644A-PU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
64KB (32K x 16)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
40-DIP (0.600", 15.24mm)
Processor Series
ATmega
Core
AVR
Data Bus Width
8 bit
Data Ram Size
4 KB
Interface Type
JTAG, TWI, SPI, USART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
32
Number Of Timers
3
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
26.7.12
26.7.13
26.7.14
8272A–AVR–01/10
Reading the Fuse and Lock Bits
Reading the Signature Bytes
Reading the Calibration Byte
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 302
1. A: Load Command “0000 0100”.
2. Set OE to “0”, and BS2, BS1 to “00”. The status of the Fuse Low bits can now be read at
3. Set OE to “0”, and BS2, BS1 to “11”. The status of the Fuse High bits can now be read at
4. Set OE to “0”, and BS2, BS1 to “10”. The status of the Extended Fuse bits can now be
5. Set OE to “0”, and BS2, BS1 to “01”. The status of the Lock bits can now be read at DATA
6. Set OE to “1”.
Figure 26-6. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 302
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
The algorithm for reading the Calibration byte is as follows (refer to
page 302
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
164A/164PA/324A/324PA/644A/644PA/1284/1284P
DATA (“0” means programmed).
DATA (“0” means programmed).
read at DATA (“0” means programmed).
(“0” means programmed).
for details on Command and Address loading):
for details on Command and Address loading):
for details on Command loading):
Extended Fuse Byte
Fuse Low Byte
Fuse High Byte
Lock Bits
BS2
BS2
0
1
0
1
BS1
0
1
”Programming the Flash” on
”Programming the Flash” on
”Programming the Flash”
DATA
307