HD64F2638F20J Renesas Electronics America, HD64F2638F20J Datasheet - Page 507

IC H8S MCU FLASH 256K 128-QFP

HD64F2638F20J

Manufacturer Part Number
HD64F2638F20J
Description
IC H8S MCU FLASH 256K 128-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2638F20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2638F20J
Manufacturer:
PENESAS
Quantity:
252
H8S/2639, H8S/2638, H8S/2636,
H8S/2630, H8S/2635 Group
Bit 3—Multiprocessor Interrupt Enable (MPIE): Enables or disables multiprocessor interrupts.
The MPIE bit setting is only valid in asynchronous mode when the MP bit in SMR is set to 1.
The MPIE bit setting is invalid in clocked synchronous mode or when the MP bit is cleared to 0.
Bit 3
MPIE
0
1
Note: * When receive data including MPB = 0 is received, receive data transfer from RSR to RDR,
Bit 2—Transmit End Interrupt Enable (TEIE): Enables or disables transmit end interrupt
(TEI) request generation when there is no valid transmit data in TDR in MSB data transmission.
Bit 2
TEIE
0
1
Note: * TEI cancellation can be performed by reading 1 from the TDRE flag in SSR, then clearing it
REJ09B0103-0800 Rev. 8.00
May 28, 2010
receive error detection, and setting of the RDRF, FER, and ORER flags in SSR , is not
performed. When receive data including MPB = 1 is received, the MPB bit in SSR is set to
1, the MPIE bit is cleared to 0 automatically, and generation of RXI and ERI interrupts
(when the TIE and RIE bits in SCR are set to 1) and FER and ORER flag setting is enabled.
to 0 and clearing the TEND flag to 0, or clearing the TEIE bit to 0.
Description
Multiprocessor interrupts disabled (normal reception performed)
[Clearing conditions]
Multiprocessor interrupts enabled *
Receive interrupt (RXI) requests, receive error interrupt (ERI) requests, and setting
of the RDRF, FER, and ORER flags in SSR are disabled until data with the
multiprocessor bit set to 1 is received.
Description
Transmit end interrupt (TEI) request disabled *
Transmit end interrupt (TEI) request enabled *
When the MPIE bit is cleared to 0
When MPB= 1 data is received
Section 13 Serial Communication Interface (SCI)
(Initial value)
(Initial value)
Page 457 of 1458