UPD78F1146AGB-GAH-AX Renesas Electronics America, UPD78F1146AGB-GAH-AX Datasheet - Page 169

no-image

UPD78F1146AGB-GAH-AX

Manufacturer Part Number
UPD78F1146AGB-GAH-AX
Description
MCU 16BIT 78K0R/KX3 64-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1146AGB-GAH-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1146AGB-GAH-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
5.6.2 Example of controlling internal high-speed oscillation clock
The following describes examples of clock setting procedures for the following cases.
(1) When restarting oscillation of the internal high-speed oscillation clock
(2) When using internal high-speed oscillation clock as CPU/peripheral hardware clock
(3) When stopping the internal high-speed oscillation clock
(1) Example of setting procedure when restarting oscillation of the internal high-speed oscillation clock
(2) Example of setting procedure when using internal high-speed oscillation clock as CPU/peripheral
(b) To stop X1 oscillation (disabling external clock input) by setting MSTOP to 1
<1> Setting restart of oscillation of the internal high-speed oscillation clock (CSC register)
Note After a reset release, the internal high-speed oscillator automatically starts oscillating and the internal
hardware clock
<1> Restarting oscillation of the internal high-speed oscillation clock
Note This setting is required to resume the X1 clock oscillation when the high-speed system clock is in the
<1> Confirming the CPU clock status (CKC register)
<2> Setting of X1 clock oscillation stabilization time after restart of X1 clock oscillation
<3> Stopping the high-speed system clock (CSC register)
Caution Be sure to confirm that MCS = 0 or CLS = 1 when setting MSTOP to 1. In addition, stop
When HIOSTOP is cleared to 0, the internal high-speed oscillation clock restarts oscillation.
(See 5.6.2 (1) Example of setting procedure when restarting internal high-speed oscillation clock).
high-speed oscillation clock is selected as the CPU/peripheral hardware clock.
CLS
Note The setting of <1> is not necessary when the internal high-speed oscillation clock is operating.
0
0
1
Confirm with CLS and MCS that the CPU is operating on a clock other than the high-speed system
clock.
When CLS = 0 and MCS = 1, the high-speed system clock is supplied to the CPU, so change the
CPU clock to the subsystem clock or internal high-speed oscillation clock.
Prior to setting "1" to MSTOP, set the OSTS register to a value greater than the count value to be
confirmed with the OSTS register after X1 clock oscillation is restarted.
When MSTOP is set to 1, X1 oscillation is stopped (the input of the external clock is disabled).
This setting is not required in the external clock input mode.
X1 oscillation mode.
peripheral hardware that is operating on the high-speed system clock.
MCS
0
1
×
Internal high-speed oscillation clock
High-speed system clock
Subsystem clock
CHAPTER 5 CLOCK GENERATOR
User’s Manual U17854EJ9V0UD
CPU Clock Status
Note
Note
Note