HD64F2676VFC33 Renesas Electronics America, HD64F2676VFC33 Datasheet - Page 49

IC H8S MCU FLASH 256K 144-QFP

HD64F2676VFC33

Manufacturer Part Number
HD64F2676VFC33
Description
IC H8S MCU FLASH 256K 144-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2676VFC33

Core Processor
H8S/2600
Core Size
16-Bit
Speed
33MHz
Connectivity
IrDA, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
103
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2676VFC33
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33
Quantity:
9 520
Part Number:
HD64F2676VFC33
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33V
Manufacturer:
ROHM
Quantity:
750 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
120
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
1.7
(1) Addressing Modes
The CPUs support the eight addressing modes listed in table 1.4. Each instruction uses a subset of
these addressing modes. Arithmetic and logic instructions can use the register direct and
immediate modes. Data transfer instructions can use all addressing modes except program-counter
relative and memory indirect. Bit manipulation instructions use register direct, register indirect, or
absolute addressing mode to specify an operand, and register direct (BSET, BCLR, BNOT, and
BTST instructions) or immediate (3-bit) addressing mode to specify a bit number in the operand.
Table 1.4
1. Register Direct—Rn: The register field of the instruction specifies an 8-, 16-, or 32-bit general
register containing the operand. R0H to R7H and R0L to R7L can be specified as 8-bit registers.
R0 to R7 and E0 to E7 can be specified as 16-bit registers. ER0 to ER7 can be specified as 32-bit
registers.
2. Register Indirect—@ERn: The register field of the instruction code specifies an address
register (ERn) which contains the address of the operand in memory. If the address is a program
instruction address, the lower 24 bits are valid and the upper 8 bits are all assumed to be 0 (H'00).
3. Register Indirect with Displacement—@(d:16, ERn) or @(d:32, ERn): A 16-bit or 32-bit
displacement contained in the instruction is added to an address register (ERn) specified by the
register field of the instruction, and the sum gives the address of a memory operand. A 16-bit
displacement is sign-extended when added.
No.
1
2
3
4
5
6
7
8
Addressing Modes and Effective Address Calculation
Addressing Mode
Register direct
Register indirect
Register indirect with displacement
Register indirect with post-increment
Register indirect with pre-decrement
Absolute address
Immediate
Program-counter relative
Memory indirect
Addressing Modes
Rev. 4.00 Feb 24, 2006 page 33 of 322
@(d:16,ERn)/@(d:32,ERn)
Symbol
Rn
@ERn
@ERn+
@–ERn
@aa:8/@aa:16/@aa:24/@aa:32
#xx:8/#xx:16/#xx:32
@(d:8,PC)/@(d:16,PC)
@@aa:8
REJ09B0139-0400
Section 1 CPU

Related parts for HD64F2676VFC33