M30626FJPFP#D5C Renesas Electronics America, M30626FJPFP#D5C Datasheet - Page 167

MCU 3/5V 512K 100-QFP

M30626FJPFP#D5C

Manufacturer Part Number
M30626FJPFP#D5C
Description
MCU 3/5V 512K 100-QFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheet

Specifications of M30626FJPFP#D5C

Core Processor
M16C/60
Core Size
16-Bit
Speed
24MHz
Connectivity
I²C, IEBus, UART/USART
Peripherals
DMA, WDT
Number Of I /o
85
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
31K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 26x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30626FJPFP#D5CM30626FJPFP
Manufacturer:
RENESAS
Quantity:
2
Company:
Part Number:
M30626FJPFP#D5CM30626FJPFP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
M30626FJPFP#D5CM30626FJPFP#U3C
Manufacturer:
MIT
Quantity:
1 831
Company:
Part Number:
M30626FJPFP#D5CM30626FJPFP#U3C
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30626FJPFP#D5CM30626FJPFP#U5C
Manufacturer:
ST
Quantity:
1 001
M16C/62P Group (M16C/62P, M16C/62PT)
Rev.2.41
REJ09B0185-0241
Figure 15.11
15.1.2.1
Timer A3
TA3OUT
(A phase)
TA3IN
(B phase)
Count source
NOTES :
ZP
This function initializes the timer count value to “0” by Z-phase (counter initialization) input during two-phase
pulse signal processing.
This function can only be used in Timer A3 event counter mode during two-phase pulse signal processing, free-
running type, x4 processing, with Z-phase entered from the ZP pin.
Counter initialization by Z-phase input is enabled by writing “0000h” to the TA3 register and setting the TAZIE
bit in the ONSF register to “1” (= Z-phase input enabled).
Counter initialization is accomplished by detecting Z-phase input edge. The active edge can be chosen to be the
rising or falling edge by using the POL bit in the INT2IC register. The Z-phase pulse width applied to the INT2
pin must be equal to or greater than one clock cycle of Timer A3 count source.
The counter is initialized at the next count timing after recognizing Z-phase input. Figure 15.11 shows the
Relationship Between the Two-Phase Pulse (A phase and B phase) and the Z-Phase.
If Timer A3 overflow or underflow coincides with the counter initialization by Z-phase input, a Timer A3
interrupt request is generated twice in succession. Do not use Timer A3 interrupt when using this function.
1. This timing diagram is for the case where the POL bit in the INT2IC register = 1 (= rising edge).
(1)
Jan 10, 2006
Counter Initialization by Two-Phase Pulse Signal Processing
Two-Phase Pulse (A phase and B phase) and the Z-Phase
Page 150 of 390
m
m+1
Input equal to or greater than one clock cycle
of count source
1
2
3
4
5
15. Timers

Related parts for M30626FJPFP#D5C