M30626FJPGP#D5C Renesas Electronics America, M30626FJPGP#D5C Datasheet - Page 98

MCU 3/5V 512K 100-LQFP

M30626FJPGP#D5C

Manufacturer Part Number
M30626FJPGP#D5C
Description
MCU 3/5V 512K 100-LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheet

Specifications of M30626FJPGP#D5C

Core Processor
M16C/60
Core Size
16-Bit
Speed
24MHz
Connectivity
I²C, IEBus, UART/USART
Peripherals
DMA, WDT
Number Of I /o
85
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
31K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 26x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30626FJPGP#D5CM30626FJPGP
Manufacturer:
ATMEL
Quantity:
1
Company:
Part Number:
M30626FJPGP#D5CM30626FJPGP
Manufacturer:
MIT
Quantity:
1 000
Company:
Part Number:
M30626FJPGP#D5CM30626FJPGP
Manufacturer:
MIT
Quantity:
20 000
Company:
Part Number:
M30626FJPGP#D5CM30626FJPGP
Manufacturer:
RENESAS
Quantity:
9 423
Company:
Part Number:
M30626FJPGP#D5CM30626FJPGP U5C
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
J Cnd
[ Syntax ]
[ Operation ]
[ Function ]
[ Selectable label ]
[ Flag Change ]
[ Description Example ]
[ Related Instructions ]
Chapter 3
*1 PC indicates the start address of the instruction.
Change
PC
PC
GEU/C C=1
EQ/Z
GTU
PZ
GE
GT
O
Cnd
Flag
J Cnd label
if true then jump label
• This instruction causes program flow to branch off after checking the execution result of the preceding
• The following conditions can be used for Cnd :
JEQ
JNE
*1
*1
–127
–126
instruction against the following condition. If the condition indicated by Cnd is true, control jumps to
label. If false, the next instruction is executed.
Z=1
C Z=1
S=0
S O=0
(S O) Z=0 Greater than (signed value)
O=1
A
U
A
____
label
label
label
I
Functions
label
label
O
Condition
Equal to or greater than
C flag is 1.
Equal to
Z flag is 1.
Greater than
Positive or zero
Equal to or greater than
(signed value)
O flag is 1.
PC
PC
B
*1
*1
+128
+129
S
BM Cnd
Z
GEU/C,GTU,EQ/Z,N,LTU/NC,LEU,NE/NZ,PZ
LE,O,GE,GT,NO,LT
D
Expression
C
Jump on Condition
Jump on condition
0
=
80
LTU/NC C=0
NE/NZ Z=0
LEU
N
LE
LT
NO
Cnd
Cnd
C Z=0
S=1
(S O) Z=1 Equal to or smaller than
S O=1
O=0
A
A
____
[ Instruction Code/Number of Cycles ]
Condition
Smaller than
C flag is 0.
Equal to or smaller than
Not equal
Z flag is 0.
Negative
(signed value)
Smaller than (signed value)
O flag is 0.
3.2 Functions
Expression
J Cnd
0
Page= 184

Related parts for M30626FJPGP#D5C