E3X-DA11-S Omron, E3X-DA11-S Datasheet - Page 21

no-image

E3X-DA11-S

Manufacturer Part Number
E3X-DA11-S
Description
RED LED NPN PREWIRE PTUNE
Manufacturer
Omron
Series
E3X-DA-Sr
Datasheet

Specifications of E3X-DA11-S

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E3XDA11S
Amplifier Unit Connectors
Item
Func-
tions
Display
Digital display
Display orientation
Ambient illumination
(Receiver side)
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Item
Rated current
Rated voltage
Contact resistance
No. of insertions
Mate-
rials
Weight
(packed state)
Housing
Contacts
I/O setting
Case
Cover
Model
2.5 A
50 V
20 m max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent Connec-
tor. It does not include the conductor resistance of the cable.)
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Polybutylene terephthalate (PBT)
Phosphor bronze/gold-plated nickel
Approx. 55 g
Model
Type
E3X-CN11/21/22
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Operation indicator
(orange), Power
Tuning indicator (or-
ange)
Select from incident
level + threshold or
other 7 patterns
Switching between normal/reversed display is possible.
Incandescent lamp: 10,000 lux max.
Sunlight:
Operating: Groups of 1 to 2 Amplifiers: 25 C to 55 C
Storage: 30 C to 70 C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
20 M
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Destruction: 500 m/s
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired or amplifier unit connector
Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Polybutylene terephthalate (PBT)
Polycarbonate (PC)
Instruction manual
E3X-DA@RM-S
External input
models
min. (at 500 VDC)
Groups of 3 to 10 Amplifiers: 25 C to 50 C
Groups of 11 to 16 Amplifiers: 25 C to 45 C
20,000 lux max.
2
, for 3 times each in X, Y and Z directions
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Select from incident level + threshold or other 6 patterns
Twin-output mod-
E3X-DA@TW-S
Approx. 25 g
els
Advanced models
E3X-CN12
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
ATC function mod-
E3X-DA@AT-S
els
Analog output set-
ting (offset voltage
adjustable)
Operation indicator
(orange),
Power Tuning indi-
cator (orange)
Mobile Console
Item
Applicable
Sensors
Power supply
voltage
Connection
method
Weight
(packed state)
Refer to Instruction Manual provided with
the Mobile Console for details.
E3X-DA@AN-S
Analog output
models
Model
E3X-DA-S/MDA
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Charged with AC adapter
Connected via adapter
Approx. 580 g (Console
only: 120 g)
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Operation indicator
for channel 1 (or-
ange), Operation in-
dicator for channel 2
(orange)
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
E3X-MC11-SV2
2-channel models
E3X-MDA@
7

Related parts for E3X-DA11-S