E3X-DA11-S Omron, E3X-DA11-S Datasheet - Page 29

no-image

E3X-DA11-S

Manufacturer Part Number
E3X-DA11-S
Description
RED LED NPN PREWIRE PTUNE
Manufacturer
Omron
Series
E3X-DA-Sr
Datasheet

Specifications of E3X-DA11-S

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E3XDA11S
Nomenclature
Amplifier Units
E3X-DA@-S
E3X-DA@RM-S
E3X-DA@AN-S
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
2. Attach the protector seals (provided as accessories) to the sides of
Note: Attach the seals to the sides with grooves.
Lock lever
Locks the fiber.
Operation Indicator
(orange)
ON when output is
ON.
OFF when output is
OFF.
Designing
Mounting
clicks into place.
master and slave connectors that are not connected.
Main Display (Red)
Incident level, function, etc.
Precautions for Correct Use
Power Tuning Indicator
ON: Power tuning is set.
Seal
Sub-Display (Green)
Threshold, function settings,
etc.
WARNING
Mode Selector
Use to select SET or RUN mode.
Insert
Seal
Operation Keys
Function setting operations
UP
DOWN
MODE
Operation Selector
Use to switch between Light
ON and Dark ON modes.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
2. After the Amplifier Unit(s) has been separated, press down on the
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
E3X-DA@TW-S
E3X-DA@AT-S
E3X-MDA@
Operation indicator for
channel 1 (orange)
ON when output is ON.
OFF when output is OFF.
Lock lever
Locks the fiber.
Note: 1. The specifications for ambient temperature will vary according to the
removed away from the rest of the group.
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Amplifier Units together until they click into place.
Main Display (Red)
Incident level, function, etc.
2. Always turn OFF the power supply before joining or separating
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
Amplifier Units.
Operation indicator for
channel 2 (orange)
ON when output is ON.
OFF when output is OFF.
Sub-Display (Green)
Threshold, function settings,
etc.
Mode Selector
Use to select SET or RUN mode.
E3X-DA-S/MDA
Press down
Remove
Operation Keys
Function setting operations
Channel Selector
Use to switch between channels
1 and 2.
UP
DOWN
MODE
Lever
Click into place
15

Related parts for E3X-DA11-S