E3X-DA11-S Omron, E3X-DA11-S Datasheet - Page 3

no-image

E3X-DA11-S

Manufacturer Part Number
E3X-DA11-S
Description
RED LED NPN PREWIRE PTUNE
Manufacturer
Omron
Series
E3X-DA-Sr
Datasheet

Specifications of E3X-DA11-S

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E3XDA11S
4
No complicated mode settings.
Insufficient light or saturation at short distances can be corrected.
Variations between different Sensors can be eliminated.
Industry's First Power Tuning Function in a Digital Sensor.
Earlier Method
Troublesome power adjustments have been eliminated, so it isn't necessary
to select from power mode settings, such as long-distance mode, standard
mode, and short-distance mode. When the MODE Key is pressed once, the
power tuning function shifts the power level so that the present incident level
is set to the ideal level (2000 on the digital display.)
The power tuning range is extended to the allowable limits to eliminate prob-
lems such as insufficient light or detection failures due to saturation.
If the installation distance is too short, the incident light may saturate (i.e., to
a digital incident level of 4,000), preventing detection. The power can be
tuned down to 1/25th of the default setting for stable detection even at close
range.
Threshold levels had to be set and maintained separately for individual Sen-
sors due to variations in the digital light levels measured by each Sensor.
With power tuning, the incident level can be fine-tuned so the same thresh-
old level can be set for each Sensor in an application. Maintenance is also
simplified because it is easier to recognize measurement levels that have
shifted during operation.
Without workpiece
With workpiece
Detecting missing tablets
High-speed mode
Short-distance mode
Standard mode
Long-distance mode
Super-long-distance mode
Transparent workpiece
The best mode for each application was
selected from several power modes.
Incident level Threshold level
Detection is not possible
Earlier Method
Digital light levels vary due to individual
differences in the Sensors, so the
threshold levels must be set individually.
Incident level
does not change.
Incident
insufficient
Appropriate
Appropriate
Saturated
Saturated
New Method
No power modes
New Method
All of the Amplifiers are set to the same digi-
tal light level, so the same threshold level
can be set and maintained for the Sensors.
The Sensor can be used immediately without
setting the mode.
If the incident light level is too high or too low,
just press the Mode key to achieve the optimum
status.
Incident level changes.
Detection is possible.
Up to 5-fold increase
Up to 1/25 reduction
Press
Patent Pending
Press
Press
An incident level/threshold display, percentage/threshold display, and large bar graph display
have been added, so you can select the best display method for the application.
Large, Easy-to-Read Displays: Clear Even from a Distance
The displays are large and easy-to-read,
despite the small case.
Settings can be made more simply and confident-
ly with two digital displays. For example, the
threshold value can be changed while reading the
incident level or a setting can be changed while
confirming the setting's function item number.
Incident Level/Peak Hold Display
Incident Level/Threshold Display
Change the threshold level while read-
ing the incident level.
Incident level
Incident level
Peak hold
Seven Convenient Display Formats
Threshold level
Simultaneously display the peak hold level and
present incident level. The optical axis can be
adjusted more easily and surely by checking the
peak hold level while adjusting the optical axis.
Function numbers
added to function
items.
SET mode
RUN mode
Verify the difference between the inci-
dent level and threshold level while set-
ting the threshold level.
Percentage/Threshold Display
Incident level
Large, bright
operation indicator
(like earlier models)
Industry's largest
characters: 6 mm
(like earlier models)
Threshold level
Peak Hold/Bottom Hold Display
Threshold
level
2010
Display the peak level when light was brightest and bottom level when light was
dimmest. The digital levels of high-speed objects can be read precisely.
(Refreshing the hold level was changed from a fixed time to synchronizing with
the output, so the peak and bottom hold values can be checked with certainty.)
Incident level
Function
1350
Threshold level
Incident light
2055
Setting
Check the incident level intuitively. Ideal
when it is better to view an analog dis-
play instead of the actual digital level.
Large Bar Graph Display
Power tuning indicator added
to indicate setting status.
1280
Bar display
Settings are now reversible.
No incident light
Patent Pending