CY8C3446AXA-098

Manufacturer Part NumberCY8C3446AXA-098
DescriptionIC MCU 8BIT 64KB FLASH 100TQFP
ManufacturerCypress Semiconductor Corp
SeriesPSOC™ 3 CY8C34xx
CY8C3446AXA-098 datasheets

Availability: By request

International delivery:

Warranty: 60 days

Shipping & payment terms

Added to cart

 

Specifications of CY8C3446AXA-098

Core Processor8051Core Size8-Bit
Speed50MHzConnectivityEBI/EMI, I²C, LIN, SPI, UART/USART, USB
PeripheralsCapSense, DMA, POR, PWM, WDTNumber Of I /o62
Program Memory Size64KB (64K x 8)Program Memory TypeFLASH
Eeprom Size2K x 8Ram Size8K x 8
Voltage - Supply (vcc/vdd)1.71 V ~ 5.5 VData ConvertersA/D 2x12b, D/A 1x8b
Oscillator TypeInternalOperating Temperature-40°C ~ 85°C
Package / Case*Lead Free Status / RoHS StatusLead free / RoHS Compliant
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
Page 101
102
Page 102
103
Page 103
104
Page 104
105
Page 105
106
Page 106
107
Page 107
108
Page 108
109
Page 109
110
Page 110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
Page 106/126

Download datasheet (5Mb)Embed
PrevNext
11.5 PSoC System Resources
Specifications are valid for –40 °C ≤ T
≤ 85 °C and T
A
except where noted.
11.5.1 POR with Brown Out
For brown out detect in regulated mode, V
mode.
Table 11-64. Precise power-on Reset (PRES) with Brown Out DC Specifications
Parameter
Description
Precise POR (PPOR)
PRESR
Rising trip voltage
PRESF
Falling trip voltage
Table 11-65. Power-on Reset (POR) with Brown Out AC Specifications
Parameter
Description
PRES_TR Response time
V
/V
droop rate
DDD
DDA
11.5.2 Voltage Monitors
Table 11-66. Voltage Monitors DC Specifications
Parameter
Description
LVI
Trip voltage
LVI_A/D_SEL[3:0] = 0000b
LVI_A/D_SEL[3:0] = 0001b
LVI_A/D_SEL[3:0] = 0010b
LVI_A/D_SEL[3:0] = 0011b
LVI_A/D_SEL[3:0] = 0100b
LVI_A/D_SEL[3:0] = 0101b
LVI_A/D_SEL[3:0] = 0110b
LVI_A/D_SEL[3:0] = 0111b
LVI_A/D_SEL[3:0] = 1000b
LVI_A/D_SEL[3:0] = 1001b
LVI_A/D_SEL[3:0] = 1010b
LVI_A/D_SEL[3:0] = 1011b
LVI_A/D_SEL[3:0] = 1100b
LVI_A/D_SEL[3:0] = 1101b
LVI_A/D_SEL[3:0] = 1110b
LVI_A/D_SEL[3:0] = 1111b
HVI
Trip voltage
Table 11-67. Voltage Monitors AC Specifications
Parameter
Description
Response time
Document Number: 001-53304 Rev. *K
≤ 100 °C, except where noted. Specifications are valid for 1.71 V to 5.5 V,
J
must be ≥ 2.0 V. Brown out detect is not available in externally regulated
and V
DDD
DDA
Conditions
Factory trim
Conditions
Sleep mode
Conditions
Conditions
®
PSoC
3: CY8C34 Family
Data Sheet
Min
Typ
Max
Units
1.64
1.68
V
1.62
1.66
V
Min
Typ
Max
Units
0.5
µs
5
V/sec
Min
Typ
Max
Units
1.68
1.73
1.77
V
1.89
1.95
2.01
V
2.14
2.20
2.27
V
2.38
2.45
2.53
V
2.62
2.71
2.79
V
2.87
2.95
3.04
V
3.11
3.21
3.31
V
3.35
3.46
3.56
V
3.59
3.70
3.81
V
3.84
3.95
4.07
V
4.08
4.20
4.33
V
4.32
4.45
4.59
V
4.56
4.70
4.84
V
4.83
4.98
5.13
V
5.05
5.21
5.37
V
5.30
5.47
5.63
V
5.57
5.75
5.92
V
Min
Typ
Max
Units
1
µs
Page 106 of 126