CL4490-1000-232 Laird Technologies, CL4490-1000-232 Datasheet - Page 15

TXRX 900MHZ RS232 1W W/ANT DB9

CL4490-1000-232

Manufacturer Part Number
CL4490-1000-232
Description
TXRX 900MHZ RS232 1W W/ANT DB9
Manufacturer
Laird Technologies
Series
Connexlink™r
Datasheets

Specifications of CL4490-1000-232

Function
Transceiver
Modulation Or Protocol
FHSS, FSK
Frequency
902MHz ~ 928MHz
Applications
General Purpose
Interface
RS-232
Sensitivity
-99dBm
Power - Output
1000mW
Data Rate - Maximum
76.8 kbps
Features
RS 232 Interface
Voltage - Supply
7 V ~ 18 V
Package / Case
Module
Wireless Frequency
900 MHz
Interface Type
RS-232, RS-485
Board Size
121 mm x 70 mm x 30 mm
Modulation
FHSS, FSK
Security
1 byte System ID, DES
Operating Voltage
100 V to 120 V
Output Power
1000 mW
Antenna
Dipole
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
CL4490 User’s Manual
4. CL4490/CN4490 Configuration Utility Software
AeroComm provides the easy to use CL4490/CN4490 Utility Software for programming the
CL4490/CN4490. The GUI based software does not require any hardware configuration and
works by itself. The software is compatible with Microsoft® Windows 95, 98, 2000, Me, NT and
XP. CL4490/CN4490s are plug-and-play devices that work with minimal or no configuration.
However, users may refer to the AC4490 manual for details about the radio’s operation and
advanced configuration commands. The SDK Software can be used to evaluate the advanced
configuration commands. The SDK Software and AC4490 manual can be found on the Connex
Tools and Literature CD or on our website at http://www.aerocomm.com/.
Note: The users should refer to the ConnexNet manual for details about the CN4490
interface.
4.1 Installation
4.2 CL4490/CN4490 Settings
The configuration utility can be used to configure both CL4490 and CN4490. The configuration
utility defaults to CL4490 configuration when it is loaded; it can be used to configure the CN4490
by checking the CN4490 check box on the configuration page.
10/3/2005
1.
2. When prompted, accept the default directory or change to the desired directory where the
3. When finished, a window will be displayed indicating a successful installation. Select OK.
Locate the CL4490 Configuration Utility, 900 MHz link in the Software section on the
Connex Tools & Literature CD. This software is also available at
program files will be installed.
http://www.aerocomm.com/Software/Driver_CL4490_900Mhz_v.1.zip.