X2-Z11-E-A Digi International, X2-Z11-E-A Datasheet - Page 170

no-image

X2-Z11-E-A

Manufacturer Part Number
X2-Z11-E-A
Description
CONNECTPORT X2 2.4GHZ
Manufacturer
Digi International
Series
ConnectPort™ X2r
Datasheets

Specifications of X2-Z11-E-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
UDP/TCP, DHCP, SNMPv1
Frequency
2.4GHz
Applications
General Purpose
Interface
RJ-45
Sensitivity
-82dBm
Power - Output
16dBm
Data Rate - Maximum
11Mbps
Voltage - Supply
12VDC
Wireless Frequency
2.4 GHz
Interface Type
Ethernet
Modulation
DBPSK, DQPSK
Security
SSL Tunnel
Operating Voltage
9 V to 30 V
Output Power
1.2 W
Antenna
4 in Dipole
Operating Temperature Range
- 30 C to + 70 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1173
Email Settings
SNMP Settings
Event Log Settings
Notify on Fence Entry: An e-mail will be sent to the defined recipients via the
configured SMTP servers when the device has entered the geofence defined by the
geofence center and entry radius.
Notify on Fence Exit: An e-mail will be sent to the defined recipients via the
configured SMTP servers when the device has left the geofence defined by the geofence
center and exit radius.
Send Location Update Notifications When Outside Fence: An e-mail will be sent to the
defined recipients via the configured SMTP servers when the device is outside of the
geofence defined by the geofence center, and exit radius. E-mails will be sent at the
interval defined by the location update interval parameter.
Include Location Data in Body: Checking this indicates that the current location of the
device should be included in the geofence e-mail.
Trap on Fence Entry: An SNMP trap will be sent to the defined SNMP servers when
device has entered the geofence defined by the geofence center, and entry radius.
Trap on Fence Exit: An SNMP trap will be sent to the defined SNMP servers when the
device has left the geofence defined by the geofence center, and exit radius.
Send Location Update Traps When Outside Fence: An SNMP trap will be sent to the
defined SNMP servers when the device is outside of the geofence defined by the
geofence center, and exit radius. SNMP traps will be sent at the interval defined by the
location update interval parameter.
Send Fence Entry Events to Event Log: A log entry will be written when device has
entered the geofence defined by the geofence center, and entry radius.
Send Fence Exit Events to Event Log: A log entry will be written when the device has
left the geofence defined by the geofence center, and exit radius.
Send Location Update to the Event Log When Outside of the Fence: A log entry will
be written when the device is outside of the geofence defined by the geofence center,
and exit radius. Log entries will be written at the interval defined by the location update
interval parameter.
Primary SMTP Server Address: The IPv4 address of the primary SMTP email server.
Secondary SMTP Server Address: The IPv4 address of the secondary SMTP email
server.
Recipient: The email address of the recipient of the geofence report e-mail.
CC: Recipient: The email address of the carbon copy (CC:) recipient of the geofence
report e-mail.
From: The email (return) address of the originator of the geofence report e-mail.
Subject: The subject line that will appear on the geofence report e-mail.
Priority: The priority of the e-mail. Normal and high priority can be specified.
Body Text: This parameter specifies the body text for the e-mail.
C o n f i g u r e D i g i d e v i c e s
1 7 0

Related parts for X2-Z11-E-A