CB-SPA312I-02 ConnectBlue, CB-SPA312I-02 Datasheet

SERIAL PORT ADAPTER 312I BTOOTH

CB-SPA312I-02

Manufacturer Part Number
CB-SPA312I-02
Description
SERIAL PORT ADAPTER 312I BTOOTH
Manufacturer
ConnectBlue
Series
CB-SPAr
Datasheet

Specifications of CB-SPA312I-02

Function
Transceiver, Bluetooth
Modulation Or Protocol
Bluetooth v2.0, Class 1
Frequency
2.4GHz
Applications
General Purpose
Interface
RS-232
Data Rate - Maximum
54Mbps
Features
Wireless Multidrop™
Voltage - Supply
4 V ~ 6 V
Package / Case
Packaged Unit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Sensitivity
-
Other names
809-1026
INDUSTRIAL BLUETOOTH™
Serial Port Adapter™
Product Guide 3.3
cB-SPA312, cB-RSPA333

Related parts for CB-SPA312I-02

CB-SPA312I-02 Summary of contents

Page 1

... Serial Port Adapter™ Product Guide 3.3 cB-SPA312, cB-RSPA333 INDUSTRIAL BLUETOOTH™ ...

Page 2

...

Page 3

Serial Port Adapter™ Product Guide ...

Page 4

... All rights reserved. Release: 0910 Document version: 3.4 Document number: cBProduct-0610-05 (8) Printed in Sweden Trademarks Registered trademarks from other companies are: Bluetooth is a trademark owned by the Bluetooth SIG, Inc. Microsoft™, Windows™, Windows NT™, Windows 2000™, Windows CE™ ...

Page 5

Contents 1 INTRODUCTION ..................................................................................... 8 1 ELATED OCUMENTS 1 HAT IS LUETOOTH 1 CAN USE MY 1 ETTING TARTED 2 INSTALLATION .................................................................................... 11 2.1 OEM S P ERIAL ORT 2.2 S ...

Page 6

T ROUBLESHOOTING 5.3 T ECHNICAL 5.3.1 5.3.2 5.3.3 5.3.4 5.3.5 5.3.6 5.3.7 5.3.8 6 Power Supply................................................................................. 26 .............................................................................. 26 S ................................................................ 27 PECIFICATIONS Environmental ............................................................................... 27 Certifications and Compliance...................................................... 28 Type Approval ............................................................................... 28 Radio Output Power...................................................................... 28 ...

Page 7

7 ...

Page 8

... A wide range of models is available to cover a wide range of usage areas. This manual covers all the boxed Serial Port Adapters from connectBlue. It especially focuses on how to mount the Serial Port Adapter and how to use the connectors of the Serial Port Adapter ...

Page 9

... The technology is based on a radio link that offers fast and reliable transmission of voice and data information. It doesn’t require a line-of-sight connection in order to establish and maintain communication. The Bluetooth wireless Serial Port Adapter AT Commands OEM Serial Port Adapter ECI Driver with connectBlue ECI Protocol Specification Extensions User Manual 9 ...

Page 10

Bluetooth is available in mobile phones, laptops, handheld computers, industrial devices, cars, and more. 1.3 How can I use my Serial Port Adapter? Your Serial Port Adapter ...

Page 11

... If you are using the OEM Serial Port Adapter please refer to the “Electrical & Mechanical Datasheet” for the specific model, for installation instructions. The latest “Electrical & Mechanical Datasheet” can be downloaded from www.connectblue.se. 2.2 Serial Port Adapter 312i 2.2.1 Mounting Picture 3 ...

Page 12

Picture 4. The Serial Port Adapter can be mounted on a DIN socket using the mounting holes. Note that the Serial Port Adapter 312i has internal antenna. Therefore it cannot be mounted inside a shielded enclosure. 2.2.2 Power Supply If ...

Page 13

Pin 4: DTR, output, data terminal ready • Pin 5: GND, ground • Pin 6: DSR, input, data set ready • Pin 7: RTS, output, request to send • Pin 8: CTS, input, clear to send • Pin 9: ...

Page 14

Green: The current mode is data mode and no connection attempt is in progress. • Orange: The current mode is AT mode. • Purple: A connection attempt is in progress. • Blue: A connection is currently active. • Blue ...

Page 15

Power Supply The product shall have a power supply of 8-30 VDC pin 1 (-) and 2 (+) on the power connector. Use a female power connector 712 series from Binder. Picture 9. DSUB serial connector ...

Page 16

RS422 In this model, the same DSUB connector is used when using RS232, RS422 and RS485. However, in the case of RS422 and RS485, the pins have different meanings compared to RS232. For details please read the AT command ...

Page 17

For four-wire RS422 multidrop, the following connection setup shall be used: Picture 12. Note: The definition of R+/R-,T+/T- may vary between manufacturers. Four-wire RS422 connection setup 17 ...

Page 18

RS485 In the case of RS485, the same pinning as for RS422 is used, except that pins T- and R- must be connected externally and pins T+ and R+ must be connected externally to produce the signals T-/R- and ...

Page 19

19 ...

Page 20

Regulatory Information 3.1 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference ...

Page 21

... Caution Any changes or modifications NOT explicitly APPROVED by connectBlue AB could cause the device to cease to comply with FCC rules part 15,and thus void the user’s authority to operate the equipment. 21 ...

Page 22

... Declaration of Conformity We, connectBlue AB, of Norra Vallgatan 64 3V SE-211 22 Malmö, Sweden declare under our sole responsibility that our products: cB-RSPA333s (cB-0144), cB-SPA312i (cB-0090) to which this declaration relates, conforms to the following product specifications: R&TTE Directive 1999/5/EC EN 300 328 V1.7.1 (2006-05) EMC EN 301 489-1 V1 ...

Page 23

... Bluetooth SIG website Bluetooth marketing since the product is published at the When creating the EPL you shall refer to the Qualified Design ID (QDID) of the connectBlue device. Easy-to-follow EPL guides are available at assist you with the EPL. A free of charge "Bluetooth SIG Adopter membership" is required. • ...

Page 24

... For any exceptions, due to national requirements or limitations, when using your Serial Port Adapter, please visit www.bluetooth.com. Note: Changes or modifications to the product not expressly approved by connectBlue AB will void the user’s authority to operate the equipment. 5.1.1 Product Care • Do not expose your product to liquid or moisture. ...

Page 25

When using the Serial Port Adapter, you will be exposed to some of the transmitted RF energy. This exposure is well below the prescribed limits in all national and international RF safety standards and regulations. 25 ...

Page 26

Electronic Equipment Most modern electronic equipment, for example, in hospitals and cars, is shielded from RF energy. However, certain electronic equipment is not. Therefore: Note: This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Please insure ...

Page 27

You have configured your Serial Port Adapter to act as a client but you have not selected a server device to connect to. Select a server device using the configuration wizard. • Your Serial Port Adapter is too far ...

Page 28

Humidity RH 5-90% non-condensing Shock and vibration: IEC 61131-2 5.3.2 Certifications and Compliance EMC compliance: ENV 50081-1, ENV 50081-2 Environment: IEC 61131-2 Medical: IEC 60601-01-2 5.3.3 Type Approval FCC/CFR 47, part 15 for: RSPA333s, SPA312i ETS 300 328,300 826 5.3.4 ...

Page 29

Rugged Serial Port Adapter 333s 5.3.8 Dimensions Model Serial Port Adapter 312i Rugged Serial Port Adapter 333s Aluminum housing, IP65. Dimensions (with x depth x height) 63.5 x 81.5 x 25.7 mm (see 2.2.1) 75 ...