X4-A11-W-A Digi International, X4-A11-W-A Datasheet - Page 143

no-image

X4-A11-W-A

Manufacturer Part Number
X4-A11-W-A
Description
PORT XBEE 802.15.4 - WIFI802.11G
Manufacturer
Digi International
Series
ConnectPort™ X4r
Datasheets

Specifications of X4-A11-W-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
802.15.4 Zigbee
Frequency
2.4GHz
Interface
1 USB, 1 RS-232, 1 RJ-45
Sensitivity
-93dBm
Power - Output
15dBm
Data Rate - Maximum
54Mbps
Voltage - Supply
6 V ~ 30 V
Wireless Frequency
2.4 GHz
Interface Type
RS-232, Ethernet, SMA
Security
NAT, DES, 3DES, 256 bit AES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Applications
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
NS9360
Other names
602-1109
TCP Sockets profile
The TCP Sockets profile allows serial devices to communicate over a TCP network. The TCP
Server allows other network devices to initiate a TCP connection to the serial device attached to
the serial port of the Digi device.
Automatic TCP connections (autoconnection)
The TCP Client allows the Digi device to automatically establish a TCP connection to an
application or a network, known as autoconnection. Autoconnection is enabled through the TCP
Sockets profile’s setting labeled Automatically establish TCP connections.
Note
RFC 2217 support
Digi devices support RFC 2217, an extension of the Telnet protocol used to access serial devices
over the network. RFC 2217 implementations enable applications to set the parameters of remote
serial ports (baud rate, flow control, etc.), detect line signal changes, as well as receive and
transmit data. The configuration information provided in this section applies to Digi device
functioning as RFC 2217 servers.
If using the RFC 2217 protocol, do not modify the port settings from the defaults. If the port
settings have been changed, restore the factory default settings (see "Restore a device
configuration to factory defaults" on page 217). No additional configuration is required.
When the TCP Sockets profile is set, the DTR flow-control signal indicates when a
TCP socket connection has been established. This information can be useful in
monitoring the serial line and using it as a flow-control mechanism to determine when
the Digi device is connected to a remote device with which communication is being
established. This mechanism can be combined with using the DCD signal to close the
connection and the DSR signal to do RCI over serial. Together, these signals can be
used to make the Digi device auto connect to many devices, deterministically, on the
network.
C o n f i g u r e D i g i d e v i c e s
1 4 3