X8-A11-E-A Digi International, X8-A11-E-A Datasheet - Page 123

no-image

X8-A11-E-A

Manufacturer Part Number
X8-A11-E-A
Description
CONNECTPORT X8 2.4GHZ
Manufacturer
Digi International
Series
ConnectPort™ X8r
Datasheets

Specifications of X8-A11-E-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
UDP/TCP, DHCP, SNMPv1
Frequency
2.4GHz
Applications
General Purpose
Interface
RJ45, DB-9, 2 USB
Sensitivity
-93dBm
Power - Output
15dBm
Data Rate - Maximum
54Mbps
Voltage - Supply
12VDC
Wireless Frequency
2.4 GHz
Interface Type
RS-232, Ethernet, USB
Modulation
BPSK, CCK, DBPSK, DQPSK, QPSK
Security
256 bit AES, 3DES, DES, SSL Tunnel
Operating Voltage
9 V to 30 V
Output Power
3.1 W
Antenna
4 in Dipole with 2 ft Cable
Operating Temperature Range
- 30 C to + 60 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1171
Built-In Command Settings
A number of Built-In Commands are supported for execution via SMS messages sent to your Digi
device. Descriptions of built-in command-related settings for the SMS feature follow. Full detailed
descriptions of the SMS command syntax and supported command options is available on the Digi
support web site.
Supported commands
The following commands are supported.
Command options
For each built-in command, the following options are supported:
#help (alias #?)
#cli
#idigi
(alias #cwm)
#ping
Enable
The command is enabled for use via SMS. All commands are enabled by default.
Password
The configured password must be specified on the command message for that message
to be accepted for further processing. If a command-specific password is configured,
that command-specific password must be provided instead of the global command
password (if one is configured, see Global SMS Command Password above).
Specifically, a command-specific password overrides the global password, and the
global password is not considered if a command-specific password is configured in the
settings. This option is disabled (no command password required) by default. To remove
the password, simply clear the password field on the settings page.
command
Built-in
The Digi device replies to the sender via SMS with a message that specifies the
command syntax and a list of the supported, available commands that may be sent to
this device. You may obtain further help for a specific command by sending that
command as a parameter. E.g., send “#help ping” to request a help reply for the
“#ping” built-in command.
Request that a CLI command be run on the Digi device. The output from the CLI
command is returned to the sender via SMS, with a limit of around 2000 characters
for the number of CLI output characters returned in the reply.
Manage or obtain status for a device connection to a Digi iDigi (Connectware
Manager) server. The Digi device replies to the sender via SMS with a message that
contains the status or result of the requested action.
Request that the Digi device reply to the sender via SMS to verify two-way SMS
communication between the sender and the Digi device.
Description
C o n f i g u r e D i g i d e v i c e s
1 2 3