X8-A11-E-A Digi International, X8-A11-E-A Datasheet - Page 177

no-image

X8-A11-E-A

Manufacturer Part Number
X8-A11-E-A
Description
CONNECTPORT X8 2.4GHZ
Manufacturer
Digi International
Series
ConnectPort™ X8r
Datasheets

Specifications of X8-A11-E-A

Function
Transceiver, Xbee, Gateway
Modulation Or Protocol
UDP/TCP, DHCP, SNMPv1
Frequency
2.4GHz
Applications
General Purpose
Interface
RJ45, DB-9, 2 USB
Sensitivity
-93dBm
Power - Output
15dBm
Data Rate - Maximum
54Mbps
Voltage - Supply
12VDC
Wireless Frequency
2.4 GHz
Interface Type
RS-232, Ethernet, USB
Modulation
BPSK, CCK, DBPSK, DQPSK, QPSK
Security
256 bit AES, 3DES, DES, SSL Tunnel
Operating Voltage
9 V to 30 V
Output Power
3.1 W
Antenna
4 in Dipole with 2 ft Cable
Operating Temperature Range
- 30 C to + 60 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
602-1171
Industrial Automation/Modbus Bridge
Industrial Automation is supported in these Digi devices: ConnectPort X2 (non-Python version),
and ConnectPort X4.
Currently, from the web interface, it is only possible to select a different port profile than
Industrial Automation, or change the serial port settings, such as baud rate and parity. If changes
are needed from the settings established by the Industrial Automation port profile, use the set ia
command from the command-line interface.
Known limitations
Disabling and enabling the Modbus Bridge
To disable the Modbus Bridge, select a different port profile than Industrial Automation. To enable
it, reselect the Industrial Automation port profile. Any specialized settings that had been set
through “set ia” commands are lost by disabling the Modbus bridge. They must be reconfigured
when you reselect the Industrial Automation profile.
More information on Industrial Automation/Modbus
For more information on Industrial Automation, see the “set ia” command description in the Digi
Connect Family Command Reference, and the application note Remote Cellular TCP/IP Access to
Modbus Ethernet and Serial Devices, part number 90000773, available on the digi.com Support
page at http://www.digi.com/support.
Digi RealPort can be used only if the Modbus Bridge function is disabled. RealPort with
Modbus/RTU or ASCII cannot be used to access the Modbus Bridge function.
The outgoing slave idle time used for remote Modbus IP-based slaves does not always
close idle sockets predictably.
While the Modbus bridge is active, do not attempt to “Port Forward” TCP 502 or UDP
502 to local Modbus/TCP servers while the Modbus Bridge is active. This causes
neither function to work. Disable the Modbus Bridge if traditional Router/NAT function
for Modbus/TCP port 502 is desired.