CYWUSB6935-48LFXC Cypress Semiconductor Corp, CYWUSB6935-48LFXC Datasheet - Page 12

no-image

CYWUSB6935-48LFXC

Manufacturer Part Number
CYWUSB6935-48LFXC
Description
IC USB WIRELESS 2.4GHZ 48VQFN
Manufacturer
Cypress Semiconductor Corp

Specifications of CYWUSB6935-48LFXC

Frequency
2.4GHz
Data Rate - Maximum
62.5kbps
Modulation Or Protocol
DSSS, GFSK
Applications
AMR, ISM, RKE
Power - Output
0dBm
Sensitivity
-95dBm
Voltage - Supply
2.7 V ~ 3.6 V
Current - Receiving
57.7mA
Current - Transmitting
69.1mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
0°C ~ 70°C
Package / Case
48-VQFN Exposed Pad, 48-HVQFN, 48-SQFN, 48-DHVQFN
Transmitting Current
69.1mA
Data Rate
62.5Kbps
Frequency Range
2.4GHz To 2.483GHz
Modulation Type
GFSK
Rf Ic Case Style
QFN
No. Of Pins
48
Supply Voltage Range
2.7V To 3.6V
Operating
RoHS Compliant
Sensitivity Dbm
-95dBm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
428-1625

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CYWUSB6935-48LFXC
Manufacturer:
MICRON
Quantity:
1 001
Part Number:
CYWUSB6935-48LFXC
Manufacturer:
CIRRUS
Quantity:
20 000
Table 10. Receive SERDES Interrupt Status
Note
Document #: 38-16008 Rev. *E
3. All status bits are set and readable in the registers regardless of IRQ enable status. This allows a polling scheme to be implemented without enabling IRQs. The status
Bit
7
6
5
4
3
2
1
0
bits are affected by TX Enable and RX Enable (Reg 0x03, bits 7:6). For example, the receive status will read 0 if the IC is not in receive mode. These registers are
read-only.
Valid B
Valid B
Flow
Violation B
EOF B
Full B
Valid A
Flow
Violation A
EOF A
Full A
7
Name
Addr: 0x08
Flow Violation B
The Valid B bit is true when all the bits in the Receive SERDES Data B register (Reg 0x0B) are valid.
1 = All bits are valid for Receive SERDES Data B
0 = Not all bits are valid for Receive SERDES Data B
When data is written into the Receive SERDES Data B register (Reg 0x0B) this bit is set if all of the bits within the
byte that has been written are valid. This bit cannot generate an interrupt.
The Flow Violation B bit is used to signal whether an overflow or underflow condition has occurred for the Receive
SERDES Data B register (Reg 0x0B).
1 = Overflow/underflow interrupt pending for Receive SERDES Data B
0 = No overflow/underflow interrupt pending for Receive SERDES Data B
Overflow conditions occur when the radio loads new data into the Receive SERDES Data B register (Reg 0x0B)
before the prior data has been read. Underflow conditions occur when trying to read the Receive SERDES Data B
register (Reg 0x0B) when the register is empty. This bit is cleared by reading the Receive Interrupt Status register
(Reg 0x08)
The End of Frame B bit is used to signal whether an EOF event has occurred on the Channel B receive.
1 = EOF interrupt pending for Channel B
0 = No EOF interrupt pending for Channel B
An EOF condition occurs for the Channel B Receiver when receive has begun and then the number of bit times
specified in the SERDES Control register (Reg 0x06) elapse without any valid bits being received. This bit is cleared
by reading the Receive Interrupt Status register (Reg 0x08)
The Full B bit is used to signal when the Receive SERDES Data B register (Reg 0x0B) is filled with data.
1 = Receive SERDES Data B full interrupt pending
0 = No Receive SERDES Data B full interrupt pending
A Full B condition occurs when data is transferred from the Channel B Receiver into the Receive SERDES Data B
register (Reg 0x0B). This could occur when a complete byte is received or when an EOF event occurs whether or
not a complete byte has been received.
The Valid A bit is true when all of the bits in the Receive SERDES Data A Register (Reg 0x09) are valid.
1 = All bits are valid for Receive SERDES Data A
0 = Not all bits are valid for Receive SERDES Data A
When data is written into the Receive SERDES Data A register (Reg 0x09) this bit is set if all of the bits within the
byte that has been written are valid. This bit cannot generate an interrupt.
The Flow Violation A bit is used to signal whether an overflow or underflow condition has occurred for the Receive
SERDES Data A register (Reg 0x09).
1 = Overflow/underflow interrupt pending for Receive SERDES Data A
0 = No overflow/underflow interrupt pending for Receive SERDES Data A
Overflow conditions occur when the radio loads new data into the Receive SERDES Data A register (Reg 0x09)
before the prior data has been read. Underflow conditions occur when trying to read the Receive SERDES Data A
register (Reg 0x09) when the register is empty. This bit is cleared by reading the Receive Interrupt Status register
(Reg 0x08)
The End of Frame A bit is used to signal whether an EOF event has occurred on the Channel A receive.
1 = EOF interrupt pending for Channel A
0 = No EOF interrupt pending for Channel A
An EOF condition occurs for the Channel A Receiver when receive has begun and then the number of bit times
specified in the SERDES Control register (0x06) elapse without any valid bits being received. This bit is cleared by
reading the Receive Interrupt Status register (Reg 0x08).
The Full A bit is used to signal when the Receive SERDES Data A register (Reg 0x09) is filled with data.
1 = Receive SERDES Data A full interrupt pending
0 = No Receive SERDES Data A full interrupt pending
A Full A condition occurs when data is transferred from the Channel A Receiver into the Receive SERDES Data A
Register (Reg 0x09). This could occur when a complete byte is received or when an EOF event occurs whether or
not a complete byte has been received.
6
EOF B
5
[3]
Full B
REG_RX_INT_STAT
4
Description
Valid A
3
Flow Violation A
2
EOF A
CYWUSB6935
1
Default: 0x00
Page 12 of 34
Full A
0
[+] Feedback