IRAMS10UP60B International Rectifier, IRAMS10UP60B Datasheet - Page 9

PLUG N DRIVE INTELLIGENT PWR MOD

IRAMS10UP60B

Manufacturer Part Number
IRAMS10UP60B
Description
PLUG N DRIVE INTELLIGENT PWR MOD
Manufacturer
International Rectifier
Series
iMOTION™r
Type
IGBTr
Datasheets

Specifications of IRAMS10UP60B

Configuration
3 Phase
Current
10A
Voltage
600V
Voltage - Isolation
2000Vrms
Package / Case
PCB Module
Current, Input Bias
200 μA
Current, Quiescent Supply
165 μA
Current, Rms Phase
10 A
Frequency
20 KHz
Number Of Pins
25
Power Dissipation
2.2 W
Switching Loss
275 μJ
Temperature, Junction, Maximum
150 °C
Voltage, Breakdown, Collector To Emitter
600 V
Voltage, Input
20 + 0.3 V
Voltage, Input, High Level
3 V
Voltage, Input, Low Level
0.8 V
Voltage, Supply
20 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*IRAMS10UP60B

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IRAMS10UP60B
Quantity:
5 510
Part Number:
IRAMS10UP60B
Manufacturer:
IR
Quantity:
20 000
Part Number:
IRAMS10UP60B-2
Manufacturer:
ST
Quantity:
1 001
Part Number:
IRAMS10UP60B-2
Manufacturer:
IR
Quantity:
5 510
Part Number:
IRAMS10UP60B-S
Manufacturer:
IR
Quantity:
20 000
1. Electrolytic bus capacitors should be mounted as close to the module bus terminals as possible to reduce ringing and
EMI problems. Additional high frequency ceramic capacitor mounted close to the module pins will further improve perfor-
mance.
2. In order to provide good decoupling between V
tween these terminals should be located very close to the module pins. Additional high frequency capacitors, typically
0.1µF, are strongly recommended.
3. Value of the boot-strap capacitors depends upon the switching frequency. Their selection should be made based on
IR design tip DN 98-2a, application note AN-1044 or Figure 9. Bootstrap capacitor value must be selected to limit the
power dissipation of the internal resistor in series with the V
4. Current sense signal can be obtained from pin 22 and pin 23. Care should be taken to avoid having inverter current
flowing through pin 22 to mantain required current measurement accuracy.
5. After approx. 8ms the FAULT is reset. (see Dynamic Characteristics Table on page 5).
6. PWM generator must be disabled within Fault duration to garantee shutdown of the system, overcurrent condition
must be cleared before resuming operation.
7. Fault/Enable pin must be pulled-up to +5V.
Typical Application Connection IRAMS10UP60B
www.irf.com
+5V
CONTROLLER
CAPACITORS
Fault
DC BUS
Monitor
PGND
Temp
47kohm
+5V
DGND
+15V
0.1mF
1K
DGND
+5V
3-Phase AC
10mF
MOTOR
CC
-V
SS
BOOT-STRAP
CAPACITORS
W
U
and V
V
CC
. (see maximum ratings Table on page 3).
B1,2,3
-V
S1,2,3
2.2µF
Fault/Enable
V
cc
HIN1
HIN2
HIN3
(15 V)
LIN1
LIN2
LIN3
I
terminals, the capacitors shown connected be-
V
TRIP
V
V
V
TH
SS
+
-
V
V
V
B3
B2
B1
IRAMS10UP60B
V
V
V
S3
S2
S1
9

Related parts for IRAMS10UP60B