ASCX05DN Honeywell Sensing and Control, ASCX05DN Datasheet

SENSOR AMP 0-5PSID

ASCX05DN

Manufacturer Part Number
ASCX05DN
Description
SENSOR AMP 0-5PSID
Manufacturer
Honeywell Sensing and Control
Series
ASCXr
Datasheet

Specifications of ASCX05DN

Pressure Type
Differential
Operating Pressure
5 PSI
Port Size
Male, 0.08" (2mm) Tube, Dual
Output
4.75V
Voltage - Supply
4.5 V ~ 16 V
Termination Style
PCB
Operating Temperature
-25°C ~ 105°C
Package / Case
6-SIP
Interface Type
PCB Mount
Operating Pressure Range
0 To 5psi
Sensor Output
Voltage
External Depth
26.2mm
Voltage Rating
16V
Port Style
Straight
Pressure Measurement Type
Differential
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287-1003

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ASCX05DN
Manufacturer:
MELEXIS
Quantity:
340
Silicon Pressure
Sensors line Guide
The pressure is on. The answer is here. No matter the need,
Honeywell Sensing and Control (S&C) has the microstructure,
pressure sensor solution. Our sensing element design consists
of four piezoresistors galvanized with a thin, chemically etched
silicon diaphragm. A pressure change will flex the mechanism,
causing a strain in the diaphragm and the buried resistors.
The resistor values will change in proportion to the stress
FEATURES
UlTRA-low PRESSURE SEnSoRS
ASDX Series.
Features: Calibrated and temperature
compensated • ASIC-enhanced output
• Analog output with 12-bit resolution
• 12-bit digital output (I
compatible protocol) • Ratiometric output
• Enhanced response time and accuracy
• DIP package • Cost effective
Benefits: Fully calibrated and temperature
compensated with on-board ASIC
designed to provide digital correction
of sensor offset, sensitivity, temperature
coefficients, and non-linearity. Analog
output ratiometric with supply voltage over
compensated supply range with 12-bit
resolution. 12-bit I
protocol allows easy interfacing to most
commonly used microcontrollers and
microprocessors without additional
components and electronic circuitry.
Output is corrected pressure value in
hexadecimal format with 12-bit accuracy
(unsigned) and independent of the supply
voltage. Offers high level output on a cost-
effective basis. Intended for use with non-
corrosive, non-ionic working fluids such as
air and dry gases in potential applications
such as flow calibrators, ventilation and
airflow monitors, gas flow instrumentation,
sleep apnea monitoring, and therapy
equipment.
2
C- or SPI-compatible
2
C- or SPI-
CPCl Series.
Features: Calibrated and temperature
compensated • Cost effective • Small
size • Constant voltage excitation • High
impedance, low current
Benefits: Integrates silicon
micromachined sensing technology,
temperature compensation, and
calibration in a small, cost-effective
package. Tube arrangements with nylon
housings available for various pressure
applications, especially those requiring
small size or vacuum reference. Although
designed for use with non-corrosive,
non-ionic pressure media, sensors may
accommodate many potential medical
application gases.
CPXl Series.
Features: Non-calibrated and non-
temperature compensated • Small size
• Cost effective • Constant voltage
excitation • High impedance, low current
Benefits: Integrates silicon micromachined
sensing technology in a cost-effective
package. Tube arrangements with nylon
housings available for various pressure
applications, especially those requiring
small size, or vacuum reference. Although
designed for use with non-corrosive,
non-ionic pressure media, accommodates
many potential medical application gases.
applied, which produces an electrical output. So you’ll find
our components performing in potential applications including
dialysis equipment, blood analysis, centrofusion and oxygen and
nitrogen gas distribution, HVAC devices, data storage, process
controls, industrial machinery, pumps, and robotics. Honeywell
S&C is always working harder, no matter the situation. Or the
pressure.
DCXl-DS Series.
Features: Calibrated and temperature
compensated • Improved stress isolation
• Reduced output offset errors
Benefits: Based on proprietary technology
designed to reduce output offset or
common mode errors due to changes in
temperature, warm-up, long-term stability
and position sensitivity. Features calibrated
offset, full scale span and thermal error
calibration to promote accuracy for flow
pressure measurement. Industry-standard,
ported package with improved stress
isolation for printed circuit board mount
applications. Used in medical, HVAC and
industrial instrumentation applications.
XCAl Series.
Features: Calibrated and temperature
compensated • Cost effective • Constant
voltage excitation • Ratiometric output
Benefits: State-of-the-art silicon
micromachined pressure sensors. Stress-
free packaging techniques provide
calibrated and temperature compensated
pressure sensors for the most demanding
potential applications such as ventilators,
audiometers, air compressors, and
chemical analyzers.
www.honeywell.com/sensing
continued on page 9
1

Related parts for ASCX05DN

ASCX05DN Summary of contents

Page 1

... Silicon Pressure Sensors line Guide The pressure is on. The answer is here. No matter the need, Honeywell Sensing and Control (S&C) has the microstructure, pressure sensor solution. Our sensing element design consists of four piezoresistors galvanized with a thin, chemically etched silicon diaphragm. A pressure change will flex the mechanism, causing a strain in the diaphragm and the buried resistors ...

Page 2

... Silicon Pressure Sensors line Guide working better under pressure. Ultra-low The human body is a Pressure Sensors supremely sensitive mechanism, requiring equally perceptive observation. Signal conditioning Honeywell S&C offers a line of pressure sensors equal Pressure range to every task — including Device type sensors that measure the ...

Page 3

... Operating temperature range [32 °F to 122 °F] linearity & hysteresis Accuracy 0.2% typ. Mounting options SIP Ultra-low Pressure Sensors XPCl Series Signal conditioning unamplified Pressure range Device type differential, gage Output mV Calibrated yes Temperature compensated yes Operating temperature range 0 ° °C [32 °F to 158 °F] (compensated) linearity & ...

Page 4

... Silicon Pressure Sensors line Guide Ultra-low Pressure Sensors SCXl Series Signal conditioning unamplified Pressure range Device type differential, gage Output mV Calibrated yes Temperature compensated yes 0 ° °C [32 °F to 122 °F] Operating temperature range (compensated) Accuracy linearity & hysteresis 0.2% typ. Mounting options ...

Page 5

... Total error band ±1 %FSS Mounting options DIP, SIP, SMT low Pressure Sensors 24PC Series Signal conditioning unamplified 0.5 psi to 250 psi (SIP, DIP) Pressure range 1 psi to 15 psi (SMT) Device type absolute, differential, wet-wet differential, gage, vacuum gage Output mV Calibrated no Compensated no Operating temperature range -40 ° ...

Page 6

... Silicon Pressure Sensors line Guide low Pressure Sensors ASDX Series Signal conditioning amplified Pressure range 1 psi to 100 psi Device type absolute, differential, gage, bidirectional Output analog (Vdc), digital (I Calibrated yes Compensated yes 0 ° °C [32 °F to 185 °F] Operating temperature range (compensated) ...

Page 7

... Accuracy linearity & hysteresis 0.3% typ. Mounting options SIP low Pressure Sensors XPC Series Signal conditioning unamplified Pressure range 1 psi to 150 psi Device type absolute, differential, gage Output mV Calibrated yes Compensated yes Operating temperature range 0 ° ...

Page 8

... Pressure – Flow Through Sensors 24PC Flow-Through Signal conditioning unamplified Pressure range 15 psi to 30 psi Device type flow-through gage Output mV Calibrated no Compensated no Operating temperature range -40 ° °C [-40 °F to 185 °F] Accuracy linearity & hysteresis 0.75% typ. Mounting options SIP 8 www.honeywell.com/sensing ...

Page 9

... SXl Series. Features: Enhanced accuracy, low pressure readings • Cost effective • High impedance bridge • Low noise Benefits: Cost-effective components for measuring very low pressures. Low power consumption for portable and battery- operated equipment ...

Page 10

... C or SPI digital output, and 2 in SMT, SIP and DIP packages • Absolute, differential, gage and compound types • Pressure ranges from 60 mbar to 10 bar [1 psi to 150 psi] • Custom calibration available • Various pressure port options • Liquid media option ...

Page 11

... Housing provides enhanced corrosion resistance and isolation from external packaging stresses. Convenient mounting holes and pressure ports for use with standard plastic tubing. Two pins provide output voltage proportional to temperature available for use with external circuitry. Enhanced response time for potential computer peripherals and pneumatic control applications ...

Page 12

... May be used to measure vacuum or positive pressure in potential medical and environmental applications. 26PC Flow-Through Series. Features: Calibrated and temperature compensated • Miniature package • Media flow-through port • 1,78 mm [0.070 in] diameter or 5,0 mm [0.200 in] diameter flow path with minimal dead space • ...

Related keywords