WLCA2-2-TS Omron, WLCA2-2-TS Datasheet

SWITCH LIMIT ROLL W/OVRTRAVL 10A

WLCA2-2-TS

Manufacturer Part Number
WLCA2-2-TS
Description
SWITCH LIMIT ROLL W/OVRTRAVL 10A
Manufacturer
Omron
Series
WLr
Type
Limit Switchr
Datasheet

Specifications of WLCA2-2-TS

Circuit
SPDT-DM/DB
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Lever, Roller
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1000gf
Contact Form
SPDT
Contact Rating
10 Amps at 125 VoltsAC
Actuator
Roller Lever
Pole Throw Configuration
DPST
Switch Function Configuration
N.O./N.C.
Current Rating (max)
10A
Operating Temp Range
-10C to 80C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
WLCA22TS
Z2750
Wide Range of Two-circuit Switches;
Select One for the Operating
Environment/Application
• A wide selection of models are available, including the
• Microload models are added to the product lineup.
• Approved standards: EC/IEC, UL, CSA, CCC (Chinese
Features
Many Variations in Standard Limit Switches
A Wide Range of Models
The WL Series provides a complete range of Limit Switches with a
long history of meeting user needs. Select environment-resistant
specifications, actuators for essentially any workpiece, operating
sensitivity matched to the workpiece, operation indicators to aid
operation and maintenance, and various wiring specifications.
Select from Six Types of Environment Resistance
The series includes Airtight Switches, Hermetic Switches, Heat-
resistant Switches, Low-temperature Switches, Corrosion-proof
switches, and Weather-proof Switches. Select the one required by the
onsite environment.
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
Ideal for Welding Sites
Stainless steel and resins that resist adhesion of spatters are used to
prevent troubles caused by zinc powder generated during welding.
Mechanical Endurance of 30 Million Operations
Long-life Models for High-frequency Applications
Long life has been achieved by increasing the resistance to friction
and creating better sliding properties in the head mechanism. Greater
visibility is provided when setting with a fluorescent display for setting
the stroke.
overtravel models with greater OT, indicator-equipped
models for checking operation, low-temperature models,
heat-resistant models, and corrosion-proof models.
standard).
Contact your OMRON representative for information on
approved models.
Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
WL/WLM
Environment-resistant Models
Spatter-prevention Models
Be sure to read Safety Precautions on page 39 to 42 and
Safety Precautions for All Limit Switches.
Standard Models
Long-life Models
DPDB Operation
The double-pole, double-break structure ensures circuit braking.
Degree of Protection; IP67
O-rings, cover seals, and other measures provide a water-proof, drip-
proof structure (IP67).
Approved Standards to Aid Export Machines
Various WL/WLM switches are approved by UL, CSA, TÜV, EN/IEC,
and CCC making them ideal for export machines.
High-precision Models Available in All Switch Types;
Ideal for Position Control
High-precision models achieve a very small movement to operation
(approx. 5°) and a repeat accuracy that is twice that of basic models.
Operation Indicators for Easier Daily
Inspections*
Confirm operation with a neon lamp or LED for
easier startup confirmations and maintenance.
* Operation indicators are provided on Indicator-
Models with Connectors to Reduce Wiring
Reduce wiring with one-touch connection. Models with direct-wired
and prewired connectors that make Switch replacement easier are
also available.
equipped switches, Spatter-prevention Basic
Switches, and Long-life Basic Switches.
Features Common to All Models
(NO)4
(NC)1
Za
3(NO)
2(NC)
CSM_WL_WLM_DS_E_12_1
1
2
Load
Operation
indicator
Load
4
3
1

Related parts for WLCA2-2-TS

WLCA2-2-TS Summary of contents

Page 1

... Microload models are added to the product lineup. • Approved standards: EC/IEC, UL, CSA, CCC (Chinese standard). Contact your OMRON representative for information on approved models. Be sure to read Safety Precautions on page and Safety Precautions for All Limit Switches. ...

Page 2

... WL@-140 WL@-141 WL@-145 WL@-RP40 WL@-RP60 ●Heat-resistant Switches WL@-TH ●Low-temperature Switches WL@-TC ●Corrosion-proof Switches WL@-RP ●Weather-proof Switches WL@-P1 ●Basic Switches WLCA2-@S ●Microload Switches WL01@-@S ●Overtravel Switches ●High-precision Switches WLGCA2-@S ●Basic Switches WLMCA2@ ●Overtravel Switches ●High-precision Switches WLMGCA2@ WL/WLM Selection Points ❍General-purpose Switches ...

Page 3

... Mounting is compatible with WLG2. • Overtravel is large, making WL@-2 setting the dog easier. Overtravel, • Mounting is compatible 90° operation with WLCA2-2. WL@-2N • Repeat accuracy is twice that basic models. High-precision WLGCA2 • Operation is highly sensitive with only 5° pretravel. • Ideal for positioning, e.g., • ...

Page 4

... All models except overtrav- el (90° operation), fork le- ver lock (WLCA32- 43), low-temperature, heat- resistant, and indicator- equipped models Only basic (WLCA2/CA12/ CL), general-purpose over- travel (WLH2/H12/HL) and high-sensitivity overtravel (WLG2/G12/GL) models (excluding heat-resistant models silicon oxide ...

Page 5

... With the WL Series, OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for your application. The WL Series consists of four basic types: General-purpose, En- vironment-resistant, Spatter-prevention, and Long-life Switches. WLCA2 Switches can be used for the most common applications. According to Operating Environment Environment −10°C Normal Water-resistant to IP67 ...

Page 6

... General-purpose Microload Switches WL01@-S Spatter-prevention Microload Switches WL@ General-purpose Switches WL@-S Spatter-prevention Switches WLM@ Long-life Switches Models WL@-LE General-purpose, Indicator-equipped (Neon Lamp) Switches WL@-LES Spatter-prevention, Indicator-equipped (Neon Lamp) Switches WL@-LD General-purpose, Indicator-equipped (LED) Switches WL@-LDS Spatter-prevention, Indicator-equipped (LED) Switches WL@ General-purpose Switches WLM@ Long-life Switches ...

Page 7

... Spatter-prevention Switches WLMH2 Long-life Switches 10° WLG2 General-purpose Switches WLG2-@S Spatter-prevention Switches WLMG2 Long-life Switches WLCA2-2N 25° 20° WLCA2-2 General-purpose Switches WLCA2-2N General-purpose Switches 5° WLGCA2 General-purpose Switches WLGCA2-@S Spatter-prevention Switches WLMGCA2 Long-life Switches WL@2 Roller Lever Actuators WL@2-@S Roller Lever Actuators ...

Page 8

Application Examples Positioning on Production Lines Positioning on Suspended Conveyors Multilevel Car Parking Towers High-precision Positioning of Machine Tools Pallet Detection in Arc Welding Lines Limit Detection is Transport Systems WL/WLM 8 ...

Page 9

... Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) General-purpose and Environment-resistant Switches WL @ @-@ @ @ @ @ @ @ @ (1) (2) (3) (4) (5) (6) (7) (8) (9)(10) (1) Electrical Rating Blank Standard load 01 Microload Note: Dimensions are the same as the standard models. ...

Page 10

... General-purpose Switches Sensor I/O Connector Switches WL @ @-@ LD @ (1) (2) (3) (4) (5) (1) Electrical Rating Blank Standard load 01 Microload Note: Dimensions are the same as the standard models. (2) Actuator Type CA2 Roller lever: Standard model GCA2 Roller lever: High-precision model Roller lever: General-purpose H2 overtravel model ...

Page 11

... Ordering Information General-purpose Switches Standard Switches Lever Actuator Roller lever R38 Item Standard load WLCA2 Basic Microload WL01CA2 Standard load WLH2 General- purpose Microload WL01H2 Standard load WLG2 High- sensitivity Microload WL01G2 Overtravel Standard load WLCA2-2 Microload WL01CA2-2 90° operation Standard load WLCA2-2N ...

Page 12

... LED WLSD-LD Flexible Rod Actuator Coil spring (spring diameter: 6.5) Item Neon lamp WLNJ-LE Flexible rod LED WLNJ-LD Roller lever R50 Model Model WLCA2-7LE WLCA2-7LD — — — — — — — — — — Adjustable rod lever 350 to 380 mm Model Model — ...

Page 13

... WLD2-LDK43 — Airtight seal WLD2-55LDK43 — Item Basic General-purpose Built-in switch Model Model specification Standard WLCA2-LD-M1J WLH2-LD-M1J Airtight seal WLCA2-55LD-M1J — Standard WLCA2-LD-M1GJ WLH2-LD-M1GJ Airtight seal WLCA2-55LD-M1GJ — Standard — — Airtight seal WLCA2-55LD-M1JB — Standard WLCA2-LD-DGJ03 WLH2-LD-DGJ03 Airtight seal WLCA2-55LD-DGJ03 — ...

Page 14

... WLCA2-TH WLH2-TH WLCA2-TC WLH2-TC WLCA2-RP WLH2-RP WLCA2-P1 WLH2-P1 Actuator Overtravel 90° (-2 model) Model WLCA2-255 WLCA2-2N55 LED WLCA2-255LD WLCA2-2N55LD Neon WLCA2-255LE WLCA2-2N55LE WLCA2-2139 WLCA2-2N139 NC wiring WLCA2-2139LD2 NO wiring WLCA2-2139LD3 — WLCA2-2N140 NC wiring — NO wiring — — NC wiring — NO wiring — WLCA2-2RP60 NC wiring WLCA2-2RP60LD2 ...

Page 15

Item No indicator Airtight seal Indicator -139 Molded -140 Hermetic terminals No indicator seal -141 Anti-coolant Heat-resistant Low-temperature No indicator Corrosion-proof Weather-proof Item Heat-resistant No indicator Low-temperature Item No indicator Airtight seal Indicator -139 Molded -140 Hermetic terminals No indicator ...

Page 16

Item No indicator Airtight seal Indicator -139 Molded Hermetic terminals No indicator -140 seal Anti-coolant Heat-resistant Low-temperature No indicator Corrosion-proof Note: The standard cable length for models with airtight seals Item No indicator Airtight seal Indicator -139 ...

Page 17

... Turn the lamp holder by 180° to change the setting to “light-ON when operating”. (Ask your OMRON representative about 2-conductor models.) *2. With 0.3-m cable attached. Roller lever Double nut lever Allen-head lever Model WLCA2-LEAS WLCA2-LES WLH2-LEAS WLH2-LES WLG2-LEAS WLG2-LES — WLGCA2-LES WLCA2-LDAS WLCA2-LDS WLH2-LDAS WLH2-LDS WLG2-LDAS WLG2-LDS — WLGCA2-LDS LED operation indicator *1 Overtravel Basic General-purpose Model Model WLMH2-LD WLMH2-LDK13A ...

Page 18

... Individual Parts Heads Actuator type Set model Head model (with Actuator) WLCA2 WL-1H1100 WLG2 WL-2H1100 Roller lever WLH2 WL-2H1100-1 WLCA2-2 WL-3H1100 WLCA2-2N WL-6H1100 WLCA12 WL-1H2100 WLG12 WL-2H2100 Adjustable WLH12 WL-2H2100-1 roller lever WLCA12-2 WL-3H2100 WLCA12-2N WL-6H2100 WLCL WL-4H4100 WLGL WL-2H4100 Adjustable ...

Page 19

... Complete Heads Double Nut with allen-head Lever levers Model Model WL-1H1100S WL-2H1100S (for WLCA2-@ or (for WLH2-@ or WLGCA2-@) WLG2-@) WL Head Replacement Heads can be replaced within the same model group. They cannot be replaced between different model groups. Group No. Set model number WLCA2 WLCA2-7 ...

Page 20

... Current (mA) 5 VDC 1 mA IP67 15,000,000 operations min. *2 750,000 operations min mm m/s (in case of WLCA2) 120 operations/minute min. 30 operations/minute min. 50/60 Hz 100 MΩ min. (at 500 VDC) 25 mΩ max. (initial value for the built-in switch when tested alone) *6 1,000 VAC (600 VAC), 50/60 Hz for ...

Page 21

... Durability is 500,000 operations min. for high-precision models. All microload models however, are 1,000,000 operations min. WL/WLM IP67 15,000,000 operations min. *2 750,000 operations min mm m/s (in case of WLCA2) 120 operations/minute min. 30 operations/minute min. 50/60 Hz 100 MΩ min. (at 500 VDC) 25 mΩ max. (initial value for the built- ...

Page 22

... VDC, resistive load) Durability * 750,000 operations min. ( 115 Electrical VAC, resistive load), but for high-pre- cision models: 500,000 operations min. ( 115 VAC, resistive load) Operating speed 1 mm m/s (in case of WLCA2) Mechanical 120 operations/minute Operating frequency Electrical 30 operations/minute Rated frequency 50/60 Hz Insulation resistance 100 MΩ ...

Page 23

... Structure and Nomenclature Structure General-purpose Switches: WLCA2 Head-mounting Screws Head The Head used in the roller lever type, adjustable rod lever type, or horizontal plunger type (except for 90° operation models) can be mounted in any of the four directions by removing the screws at the four corners of the Head. ...

Page 24

Indicators Indicator Covers The indicator covered if outsert molded from diecast aluminum and has outstanding sealing properties. Indicator Windows Operation (i.e., light-ON when operating or light-ON when not operating) depends on whether a neon lamp or LED is used. Light-ON ...

Page 25

... WL@-140 WL@-141 Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished WL@-145 diameter: 11.5 mm, 4-conductor. WL@RP40 WL@RP60 Spatter-prevention Switches: WLCA2-LEAS Actuator Roller, Roller Axis Using stainless steel prevents spatter from adhering. Operating Lever Melamine sinter-painted easy to peel off the spatter. ...

Page 26

... Long-life Switches: WLMGCA2-LD Release Plunger Hardening method changed for greater abrasion resistance. Long-life Model Standard Model Stainless Sintered steel + alloy Hardening Head The Head can be mounted in any of the four directions by removing the screws at the four corners of the Head. Shaft Section Seal ...

Page 27

... The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector. Screw Terminal Switches Indicator-equipped (Light-ON when Not Operating) Switches *1 (NO) 4 (NC) 1 Pre-wired Connector Switches Indicator-equipped (Light-ON when Not Operating) Switches *1 DC (2-core) Internal ...

Page 28

... MD max. *1. The operating characteristics for WLCA12 and WL01CA12 are measured at the lever length of 38 mm. *2. The operating characteristics for WLCL and WL01CL are measured at the rod length of 140 mm. 60 max. Roller lever R50 53 ±1.5 WLCA2-7 41.5 ±1.5 40 ±1.5 WL01CA2-7 13.1 25.4 12 ...

Page 29

Basic Plunger .....................For all models WL@ indicates a standard-load model and WL01@ indicates a microload model. Top Plunger WLD 9.2 dia. PT WL01D 1R * Four, M3.5 OP +0.2 Four, 5.2 0 dia. holes 58.7 ±0.2 Three, M4 (length: 13) ...

Page 30

Basic Flexible Rod ............ For all models WL@ indicates a standard-load model and WL01@ indicates a microload model. Coil Spring PT WLNJ *1 WL01NJ *3 (107) 140 ±2.5 32.7 ±0.8 Four, 5.2 dia. holes 58.7 ±0.2 Three, M4 (length: 13) ...

Page 31

Overtravel General-purpose/High-sensitivity Models Roller Lever R38 WLH2 17.5 dia. (length WL01H2 WLG2 Four, M3.5 38R M5 (length: 12) WL01G2 Allen-head bolt 14.7 (125) +0.2 Four, 5.2 0 dia. holes 58.7 ±0.2 Three, M4 (length: 13) 5 JIS B0202 ...

Page 32

... Adjustable range 140 (10.8) 101.8 +0 ±0.2 5 ±0 Four, M6 21.6 Depth: 15 min. 33 ±1 max. WLCL-2N *2 WLCA2-2 WLCA12-2 *1 WL01CL-2N *2 WL01CA2-2 WL01CA12-2 *1 9.61 N 2.84 N 8.83 N 8.83 N 1.18 N 0.25 N 0.49 N 0.49 N 25° ±5° 25° ±5° 20° max. 20° max. 70° 70° 60° ...

Page 33

... Connecting Cables in the Limit Switch Connectors. Refer to page 27 Roller Lever Plungers ........WL@ are Standard Models and WL01@ are Microload Models. Standard Models (WLCA2), High-precision Models (WLGCA2), Overtravel General-purpose Models (WLH2), Overtravel High-sensitivity Models (WLG2) Connector Models 17.5 dia. (length Four, M3.5 ...

Page 34

... JIS B0202 G½ (4.9) 30.2 Effective thread: ±0.2 40 ±0.7 4 threads min. * Stainless sintered roller Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Actuator WLCA2-LE/LD Operating characteristics WL01CA2-LE/LD Operating force OF max. 13.34 N Release force RF min. 2.23 N 15° ±5° Pretravel ...

Page 35

... OT min. 30° Movement Differential MD max. 12° Operating Position OP Total travel Position TTP max. Roller Lever (Pre-wired connectors) WLCA2-@S-M1J*/WL01@-@S-M1J* WLH2-@S-M1J*/WLG2-@S-M1J* WLGCA2-@S-M1J* * External dimensions are the same even for different core wires. 60 max. 54 ±1.5 13.1 25.4 12 ...

Page 36

Long-life Models Rotating Lever Models Roller Lever (Screw Terminals) WLM@-LD 17.5 dia. (length Four, M3.5 (length: 26.5) M5 (length: 12) 38R Allen-head bolt +0.2 Four, 5.2 0 14.7 dia. holes Rubber cap 58.7 ±0.2 Three, M4 (length: 13) ...

Page 37

Actuators (Levers Only) Lever: Only rotating lever models are illustrated. WL-1A100 WL-1A115 Standard Lever Resin Roller 17.9 17.5 dia. (length: 7) 17.5 dia. (length: 7) stainless sintered alloy roller 12.6 resin roller 7.3-dia. 7.3-dia. mounting mounting 38 54.8 holes holes ...

Page 38

Lever: Only rotating lever models are illustrated. WL-2A110 WL-2A105 34.5 49 dia. rubber roller 50 dia. (length: 15) Material: NBR Nylon roller 24.4 23 Adjustable Adjustable 122 from 41 to from 78.5 M5 Allen-head 7.3-dia. 7.3-dia. bolt ...

Page 39

... Using Switches for Micro Loads Contact faults may occur if a Switch for a general-load is used to switch a micro load circuit. Use switches in the ranges shown in the diagram below. However, even when using micro load models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability ...

Page 40

... Mounting Operation Set Position (Long-life Switches Only) locations For all Long-life Switching, there is a set position marker slit on the rubber cap of the head. After operation, set the slit on the rubber cap so that the fluorescent color on the shaft section can be seen ...

Page 41

... The roll- WLSD@, WL01SD@ er plunger can be set in either two po- Top-roller Plungers: sitions at 90°. WLD2, WL01D2 WLCA2-2N and WL01CA2-2N can be Sealed Top-roller Plungers: set only in either the forward or back- WLD28, WL01D28 ward direction. Does not include -RP60 Series or -141 Series ...

Page 42

Item Applicable models and Actuators Roller Levers: Installing the Roller on the Inside WLCA@, WL01CA@, WLH@, WL- CA@-2, WL01CA@-2, WLMCA2@, By installing the roller lever in the op- posite direction, the roller can be in- WLMH2@, WLMG2@, WLMGCA2@, WLG@, except ...

Page 43

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords