SWTCH LMT DPST 6A TOP BALL PLNGR

WLD3-TS

Manufacturer Part Number
WLD3-TS
Description
SWTCH LMT DPST 6A TOP BALL PLNGR
Manufacturer
Omron
Series
WLr
Datasheet

Specifications of WLD3-TS

Circuit
SPDT-DM/DB
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
2720gf
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
WLD3TS
Model Number Structure
Model Number Legend
WL @ @-@ @ @ @ @ @ @ @
(1) Electrical Rating
Note: Dimensions are the same as the standard
(3) Environment-resistant Model
Note: Dimensions are the same as the standard
*1. Refer to page 4 for applicable models.
(4) Built-in Switch Type
Note: Dimensions are the same as the standard
*1. Refer to page 4 for applicable models.
(5) Temperature Specifications
Note: Dimensions are the same as the standard
*1. Refer to page 4 for applicable models.
(7) Conduit Size, Ground Terminal
Note: Dimensions are the same as the standard
*2. Models with ground terminals are approved by
(6) Hermetic Model Specifications
* Refer to page 4 for applicable models.
Blank Standard
Blank Standard
Blank Standard: –10°C to +80°C
Blank G1/2 without ground terminal
Blank No cables or molding
Blank Standard load
RP40
RP60
General-purpose and Environment-resistant Switches
139
140
141
145
RP
TH
TC
G1
P1
TS
01
55
EN/IEC (CE marking).
G
Y
Specifications
Specifications *2
models.
models.
models.
models.
models.
(1) (2) (3) (4) (5) (6) (7) (8) (9)(10)
General-purpose built-in switch with cables attached and mold-
ed conduit opening and cover (cover cannot be removed).
Airtight built-in switch with cables attached and molded conduit open-
ing, cover, and box interior cover screws (cover cannot be removed).
Airtight built-in switch with cables attached and molded con-
duit opening, cover, head, box interior, cover screws, and
head screws (cover cannot be removed, Head direction can-
not be changed). The Head opening is created to protect it
from cutting powder.
Airtight built-in switch with cables attached and molded conduit
opening, cover, box interior, and cover screws (cover cannot be
removed, Head can be mounted in any of 4 directions). The
Head opening is created to protect it from cutting powder.
Airtight built-in switch with cables attached and molded cover and
box interior (cover cannot be removed, Head direction can be
changed). SC Connector can be removed, so it is possible to use
flexible conduits for the cable.
Airtight built-in switch with cables attached, fluorine rubber used,
and molded conduit opening, cover, and box interior (cover cannot
be removed, Head direction cannot be changed).
Microload
Corrosion-proof *1
Weather-proof *1
Hermetically sealed *1
Heat-resistant: +5°C to +120°C *1
Low-temperature: –40°C to +40°C *1
G1/2 with ground terminal
Pg13.5 with ground terminal
M20 with ground terminal
1/2-14NPT with ground terminal
*
(Not all combinations are possible. Ask your OMRON representative for details.)
*
(2) Actuator and Head Specifications
CA12-2N Adjustable roller lever: Overtravel, 90°
CA32-41 Fork lever lock: Maintained, WL-5A100
CA32-42 Fork lever lock: Maintained, WL-5A102
CA32-43 Fork lever lock: Maintained, WL-5A104
Symbol
CA2-2N
CA12-2
CA2-7
CA2-8
CA2-2
CL-2N
GCA2
NJ-30
NJ-S2
CA12
HAL4
HAL5
CL-2
NJ-2
CA2
SD2
SD3
*
H12
G12
D28
G2
CL
HL
GL
SD
H2
D2
D3
NJ
D
Roller lever: Standard model R38
Roller lever: Standard model R50
Roller lever: Standard model R63
Roller lever: General-purpose overtravel model, 80°
Roller lever: High-sensitivity overtravel, 80°
Roller lever: Overtravel, 90°
Roller lever: Overtravel, 90°
Roller lever: High-precision R38
Adjustable roller lever: Standard
Adjustable roller lever: General-purpose overtravel model, 80° WLRH2
Adjustable roller lever: High-sensitivity overtravel, 80°
Adjustable roller lever: Overtravel, 90°
Adjustable rod lever: Standard, 25 to 140 mm
Adjustable rod lever: General-purpose overtravel model, 80°, 25 to 140 mm
Adjustable rod lever: General-purpose overtravel model, 80°, 350 to 380 mm
Adjustable rod lever: High-sensitivity overtravel, 80°, 25 to 140 mm WLRG2
Adjustable rod lever: Overtravel, 90°, 25 to 140 mm
Adjustable rod lever: Overtravel, 90°, 25 to 140 mm
Rod spring lever: General-purpose overtravel model, 80°
Plunger: Top plunger
Plunger: Top-roller plunger
Plunger: Sealed top-roller plunger
Plunger: Top-ball plunger
Plunger: Horizontal plunger
Plunger: Horizontal-roller plunger
Plunger: Horizontal-ball plunger
Flexible rod: Coil spring
Flexible rod: Coil spring, multi-wire
Flexible rod: Coil spring, resin rod
Flexible rod: Steel wire
*
*
*
(8) Indicator Type
Note: Dimensions are the same for both LE and LD models.
(9) Indicator Wiring
Note: Include the indicator wiring specification only when a (6) hermetic seal
(10) Lever Type
Symbol
Blank
Blank
LD
LE
A
2
3
and (8) operation indicator have been selected.
Actuator type
No indicator
Neon lamp
LED
NC connection: Light-ON when operating
NO connection: Light-ON when not operating
Standard lever
Double nut lever
Element
125 to 250 VAC
115 VAC/VDC
10 to 24 VAC/VDC Approx. 0.4 mA
Voltage
Approx. 0.6 to 1.9 mA
Approx. 0.5 mA
Leakage current
WL/WLM
Switch without lever
WLRCA2
WLRCA2
WLRCA2
WLRH2
WLRG2
WLRCA2-2
WLRCA2-2N
WLRGCA2
WLRCA2
WLRG2
WLRCA2-2
WLRCA2-2N
WLRCL
WLRH2
WLRH2
WLRCA2-2
WLRCA2-2N
WLRH2
WLRCA32
WLRCA32
WLRCA32
9

Related parts for WLD3-TS