EA STARTEDIP320J ELECTRONIC ASSEMBLY, EA STARTEDIP320J Datasheet - Page 16

LCD Graphic Display Modules & Accessories Starter/Demoboard w/Touch USB prog

EA STARTEDIP320J

Manufacturer Part Number
EA STARTEDIP320J
Description
LCD Graphic Display Modules & Accessories Starter/Demoboard w/Touch USB prog
Manufacturer
ELECTRONIC ASSEMBLY
Datasheet

Specifications of EA STARTEDIP320J

Pixel Density
320 x 240
Fluid Type
FSTN Positive
Module Size (w X H X T)
121 mm x 92.6 mm x 11.6 mm
Viewing Area (w X H)
115.18 mm x 86.38 mm
Backlighting
Black / White
Background Color
White
Operating Temperature Range
- 20 C to + 70 C
Attached Touch Screen
Yes
Interface
RS-232, I2C BUS, or SPI BUS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EA eDIP320-8
Page 16
Command
Save display contents
Save area
Restore area
Copy area
Set menu font
Menu font zoom factor
Add. line spacing
Menu angle
Touch menu automation
Define and display menu
Next item
Previous item
End of menu/send
End of menu/macro
End of menu/cancel
Run normal macro
Run touch macro
Run menu macro
Disable macros
Enable macros
Select macro/image page
Save macro/image page
Restore macro/image page
Macro with delay
Autom. macros once only
Autom. macros cyclical
Autom. macros ping pong
Define macro process
Macro process interval
Stop macro processes
Wait (pause)
Set RS485 address
Tone on/off
Illumination on/off
Illumination brightness
Write output port
Send bytes
Send version
Send internal information
Power down
Codes
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
M
M
M
C
N
N
X
K
Y
S
P
n1
B
S
R
K
Y
W
D
N
P
S
M
A
N
M
U
K
W
R
G
E
A
D
S
A
S
H
W
B
V
D
F
Z
T
T
L
J
Z
L
I
type n1
type n1
num
xx1 yy1 xx2 yy2
xx1 yy1
xx1 yy1
adr
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
n1
no type n3
nr
n1
n1
n1
n1
n1
n1
Menu box commands (control with keys rather than by touch)
n2
n2
n2
n2
n2
zs
n2
EA eDIP320-8: Command table 2
no
n2
n2
n3
n3
n3
data ...
Clipboard commands (buffer for image areas)
text
n4
...
settings for menu box/touch menu
NUL
zs
automatic (Normal) Macros
Remarks
The entire contents of the display are copied to the clipboard as an image area
The image area from xx1,yy1 to xx2,yy2 is copied to the clipboard
The image area on the clipboard is copied back to the display
The image area on the clipboard is copied to xx1,yy1 in the display
Set font with the number n1 (0 to 31) for menu display
n1 = X zoom factor (1x to 8x); n2 = Y zoom factor (1x to 8x)
Insert n1 pixels (0 to 15) between two menu items as additional line spacing
Menu display angle: n1=0: 0°; n1=1: 90°; n1=2: 180°; n1=3: 270°
n1=1: Touch menu opens automatically; n1=0:Touch menu does not open automatically;
instead, the request 'ESC T 0' to open is sent to the host computer, which can then open the
touch menu with 'ESC N T 2'.
A menu is drawn as of the corner xx1,yy1 with the current menu font. no= currently inverted
entry (e.g.: 1 = 1. entry) Text:= string with menu items. The different items are separated by
the character '|' ($7C,dec:124) (e.g. "item1|item2|item3"). The background of the menu is
saved automatically. If a menu is already defined, it is automatically canceled+deleted.
The next item is inverted or remains at the end
The previous item is inverted or remains at the beginning
The menu is removed and replaced with the original background. The current item is sent as
a number (1 to n) (0=no menu displayed)
The menu is removed and replaced with the original background. Menu macro n1 is called for
item 1, menu macro nr+1 for item 2, and so on
The menu is removed and replaced with the original background
Call the (normal) macro with the number n1 (0 to 255) (max. 7 levels)
Call the touch macro with the number n1 (0 to 255) (max. 7 levels)
Call the menu macro with the number n1 (0 to 255) (max. 7 levels)
Macros of the type 'N', 'T' or 'M' (type 'A' = all macro types) are disabled from the number n1
to n2; i.e. no longer run when called.
Macros of the type 'N', 'T' or 'M' (type 'A' = all macro types) are enabled from number n1 to
n2; i.e. run again when called.
A page is selected for macros and images n1=0 to 15. if a macro/image is not defined in the
current page 1 to 15, this macro/image is taken from page 0 (e.g. to switch languages or for
horizontal/vertical installation).
the current macro/image page is saved (when used in process macros)
the last saved macro/image page is restored
Call the (normal) macro with the number n1 (0 to 255) in n2/10S. Execution is stopped by
commands (e.g. receipt or touch macros).
Automatically run macros n1 to n2 once only; n3=pause in 1/10s. Execution is stopped by
commands (e.g. receipt or touch macros).
Automatically run macros n1 to n2 cyclically; n3=pause in 1/10s. Execution is stopped by
commands (e.g. receipt or touch macros).
Automatically run macros n1 to n2 to n1 (ping pong); n3=pause in 1/10s. Execution is
stopped, for example, by receipt or touch macros.
A macro process with the number no (1 to 8) is defined (1=highest priority). The (Normal)
Macros n3 to n4 are run successively every zs/10s. type: 1=once only; 2=cyclical; 3=ping
pong n3 to n4 to n3
a new time zs is assigned to the macro process with the number nr (1 to 8) in 1/10s. if the
time zs=0, execution is stopped.
all macro processes are stopped with n1=0 and restarted with n1=1 in order, for example, to
execute settings and outputs via the interface undisturbed
Wait n1 tenths of a second before the next command is executed.
for RS232/RS485 operation only and only possible when Hardware address is 0. The eDIP is
assigned a new address adr (in the Power-On macro).
The tone output (pin 16) becomes n1=0: OFF; n1=1: ON; n1=2 to 255: switched on for n1
tenths of a second
LED illumination n1=0: OFF; n1=1: ON; n1=2 to 255: illumination switched on for n1 tenths of
a second.
set brightness of the LED illumination n1=0 to 100%. n1=250 save current brightness as
starting brightness; n1=254 switch LED off immediately; n1=255 switch to 100% immediately.
n1=0: Set all output ports in accordance with n2 (=6/8-bit binary value). n1=1 to 6/8: Reset
port n1 (n2=0); set (n2=1); invert (n2=2);
num (=1 to 255) bytes are sent to the send buffer... = num Bytes. in the source text of the
macro programming, the number nUM must not be specified. This is counted by the edip
compiler and entered.
the version is sent as a string (e.g. "EA eDIP320-8 V1.0 Rev.A tp+")
internal information is sent by the edip.
After this command, the display goes into power-down mode. n1=0: wake up only after reset;
n1=1: wake up on L level at WUP Pin n1=2: wake up on touch; n1=3: wake up on WUP Pin or
Touch
Macro commands
macro processes
Other commands
Specifications may be changed without
prior notice. Printing error reserved
After
reset
OFF
100
to 1
1,1
0
0
1
1
1

Related parts for EA STARTEDIP320J