AVR-ISP500-ISO Olimex Ltd., AVR-ISP500-ISO Datasheet

Programmers & Debuggers AVR PROGRAMMER 2MB FLASH 1000V

AVR-ISP500-ISO

Manufacturer Part Number
AVR-ISP500-ISO
Description
Programmers & Debuggers AVR PROGRAMMER 2MB FLASH 1000V
Manufacturer
Olimex Ltd.
Datasheet

Specifications of AVR-ISP500-ISO

Positions/sockets
1
Description/function
USB AVR Programmer
Tool Type
Programmer
Core Architecture
AVR
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
AVR Studio
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AVR-ISP500-ISO
Users Manual
All boards produced by Olimex are ROHS compliant
Rev.B, January 2009
Copyright(c) 2009, OLIMEX Ltd, All rights reserved

Related parts for AVR-ISP500-ISO

AVR-ISP500-ISO Summary of contents

Page 1

... AVR-ISP500-ISO All boards produced by Olimex are ROHS compliant Copyright(c) 2009, OLIMEX Ltd, All rights reserved Rev.B, January 2009 Users Manual ...

Page 2

... AvrStudio, and disconnect the programmer from the PC. Next time button is pressed the programmer will invoke all previously recorded steps without the need for connection to the PC. We believe this feature makes AVR-ISP500-ISO the perfect tool for firmware upgrades in remote places. FEATURES: - Fully STK500v2 compatible ...

Page 3

... CONNECTOR SCHEMATICS: PC DRIVER INSTALLATION: Download drivers for your Operating System from our website. Windows installation steps are the following: 1. Download and unzip the file “AVR-STK500-ISO-drivers.zip” temporary directory. 2. Plug the programmer in the USB port. 3. Point the Device Wizard to the temporary directory. ...

Page 4

... WARNING: The COM port number assigned by Windows to AVR-ISP500- ISO must be COM4 or below. Otherwise AvrStudio might not be able to detect the programmer. Here are the steps to change it Device Manager. ...

Page 5

Unfold “Ports (COM&LPT)” and right-click on “USB Serial Port (COMxx)” where COMxx can be anything between COM1 and COM255. Select properties the “Port Settings” tab and click the “Advanced” button. ...

Page 6

... If a warning message pops up and complains about COM port being used by another device, click “Yes”. 7. Click OK to close the device properties. USING AVR-ISP500-ISO WITH AVRSTUDIO: WARNING: ISO must be COM4 or below. Otherwise AvrStudio might not be able to detect the programmer. See the section for PC Drivers Installation for more information ...

Page 7

... After pressing “Connect” the programming dialog should appear: Target AVR now can be erased, flashed with a provided HEX file, FUSES and LOCK bits can be written and/or verified. For more information please consult the AvrStudio documentation. CAVEAT: and ARef in the “HW SETTINGS” tab, these actions will have no effect. The programmer simultaneously in the VTARGET and ARef sliders ...

Page 8

... GREEN LED is on constantly. The right LED of AVR-ISP500-ISO is a bi-color LED which shows the last autonomous operation status for indefinite time. Again, RED is for error, GREEN is for success, off if no status is available due to ongoing operation. ...

Page 9

... This is achieved by the “Auto” feature of AvrStudio Programming Dialog. After setting the FLASH and EEPROM files, FUSE and LOCK settings, and selecting the target AVR device, switch to the “Auto” tab of the programming dialog. Action that failed End of error code. LED0 lights constantly ...

Page 10

... CLOCK OUTPUT: Pin 3 of the ICSP10 connector is normally left unconnected by other ISP programmers. Not ours. In normal programmer state this pin is tri-stated. During programming operation, however, this pin is made output and a square-wave clock is generated. Clock frequency can be adjusted with the AvrStudio Programmer Dialog: ...

Page 11

... This clock output can be really helpful when target AVR is accidentally programmed with External Clock FUSE option. To resurrect it just wire ICSP10 pin 3 to XTAL1 pin of the target AVR chip and initiate a programming session to fix the FUSE values. CAVEAT: Mode” ...

Page 12

... User is free to use his favorite terminal client (HyperTerminal, minicom, etc) to upload the firmware images taken from our website. The serial port settings for the AVR-ISP500-ISO boot loader are: 9600 baud/sec, 8 data bits, no parity, 1 stop bit. The AVR-ISP500- TINY/MASS/NANO boot loaders implement a USB virtual serial port that is baudrate agnostic ...

Page 13

... The solution is to remove all such circuits (LEDs, RS232 drivers, resistors below 2k, etc) from the four ISP lines during programming. AVR-ISP500 is more susceptible to this kind of fault than other programmers on the market because it has 560 ohm resistors in series with all its outputs ...

Page 14

... ORDER CODE: AVR-ISP500-ISO How to order? You can order to us directly or by any of our distributors. Check our web Revision history: REV.A - create April 2008 REV.B - modify January 2009 Added a troubleshooting guide – assembled and tested (no kit, no soldering required) www.olimex.com/dev for more info. ...

Page 15

... This document is intended only to assist the reader in the use of the product. OLIMEX Ltd. shall not be liable for any loss or damage arising from the use of any information in this document or any error or omission in such ...