MOD-RFID125-BOX Olimex Ltd., MOD-RFID125-BOX Datasheet - Page 8

RFID Modules & Development Tools RFID RDR FOR 125KHZ TAGS 100x50x10mm

MOD-RFID125-BOX

Manufacturer Part Number
MOD-RFID125-BOX
Description
RFID Modules & Development Tools RFID RDR FOR 125KHZ TAGS 100x50x10mm
Manufacturer
Olimex Ltd.
Datasheet

Specifications of MOD-RFID125-BOX

Operating Current
120 mA
Operating Voltage
5 V
Product
RFID Readers
Wireless Frequency
125 KHz
Interface Type
UART
Dimensions
100 mm x 50 mm
Kit Features
USB Plug In Module, Read RFID125 KHz Tags From Up To 5-15 CM Distance, RS232, USB, SPI Interface
Tool Type
Wireless Development Kit
Processor To Be Evaluated
Multiple
Core Architecture
Multiple
Cpu Core
Multiple
Processor Series
Multiple
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1776327 52R3637
COMMAND LINE INTERFACE (USB CDC and UART modes):
The command line interface, available in USB CDC and UART modes,
allows device configuration and reading of successfully decoded TAG IDs.
Just open the serial port assigned to MOD-RFID125 using HyperTerminal
or similar terminal program, and start typing commands.
For the impatient: type '?' and press enter to see a short help for the
supported commands. Any typed character will be echoed back; 'enter' will
force the module to process the input command line.
1.
This command prints a short help message, describing the available
commands and their arguments.
2.
This command prints a short information about firmware version,
hardware board revision, and currently selected configuration.
3.
This command forces the device to enter boot loader mode. After
executing this command the device will disconnect itself from USB,
switch to boot loader mode, and reconnect itself in anticipation of
receiving a firmware upgrade image. See the section “Firmware
Upgrade” for more information.
4.
This command is only valid if device is in single read mode (see
below). It will trigger a single TAG read. If TAG ID is successfully
read, it will be printed. Otherwise if operation timed out, zeros will
be printed.
5.
Set single read mode. The XX parameter must be a decimal value,
indicating the TAG read timeout in seconds.
Example – setting single read mode with 15 seconds timeout:
6.
Set continuous read mode with frequency F (Hz) and repeat report
interval R (seconds). Both F and R must be single digit decimal
numbers.
If F is 0 then RF antenna is constantly switched on and the device is
scans continuously for tags. Otherwise if F is 1-5, the device will
switch the antenna on F times per second.
If R is 0 then a successfully read RF tag ID is reported only once.
Otherwise if R is 1-9, the device will report the tag ID every R
seconds until the tag is seen in the proximity.
Example – continuous scanning, single report per seen tag:
Example – scan once per second, single report per seen tag:
Command ?
Command i
Command b
Command r
Command msXX
Command mcFR
ms15
mc00
mc10