B32632A1103J10 EPCOS Inc, B32632A1103J10 Datasheet

Polypropylene Film Capacitors 0.01uF 1600V 5% Crimped Leads

B32632A1103J10

Manufacturer Part Number
B32632A1103J10
Description
Polypropylene Film Capacitors 0.01uF 1600V 5% Crimped Leads
Manufacturer
EPCOS Inc
Series
B32632r
Datasheet

Specifications of B32632A1103J10

Voltage Rating
1.6 KVolts
Termination Style
Radial
Dimensions
12.5 mm W x 19 mm L x 17.5 mm H
Operating Temperature Range
- 55 C to + 110 C
Dissipation Factor Df
1
Load Life
200000 Hrs
Product
Metallized Polypropylene Capacitors
Capacitance
0.01 uF
Tolerance
5 %
Lead Spacing
15 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
B32632A1103J010
Film Capacitors
Metallized Polypropylene Film Capacitors (MFP)
Series/Type:
Date:
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
B32632 ... B32634
May 2009

Related parts for B32632A1103J10

B32632A1103J10 Summary of contents

Page 1

... Film Capacitors Metallized Polypropylene Film Capacitors (MFP) Series/Type: B32632 ... B32634 Date: May 2009 © EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. ...

Page 2

... HID lamps Climatic Max. operating temperature: 110 C Climatic category (IEC 60068-1): 55/100/56 Construction Dielectric: polypropylene (PP) Film metallized on one side and metal foils internally connected in series Contact layer of sprayed metal Wound capacitor technology Epoxy resin coating (UL 94 V-0) Features Highest possible contact reliability ...

Page 3

Dimensional drawings Dimensions in mm Lead spacing Lead diameter 0 15.0 0.8 22.5 0.8 27.5 0.8 Please read Cautions and warnings and Important notes at the end of this document. Very high pulse (wound) Detail of double crimped ...

Page 4

B32632 ... B32634 Very high pulse (wound) Overview of available types Lead spacing 15.0 mm Type B32632 V (V DC) 630 1250 1600 AC) 300 450 450 RMS C (nF) R 0.47 0.68 1.0 1.5 2.2 3.3 ...

Page 5

Overview of available types Lead spacing 27.5 mm Type B32634 V (V DC) 630 AC) 300 RMS C (nF 100 150 220 330 Lead configurations Series Standard B32632 15 mm ...

Page 6

B32632 Very high pulse (wound) Ordering codes and packing units (lead spacing 15 mm Max. dimensions R RMS kHz 630 300 2.2 6.0 3.3 6.0 4.7 ...

Page 7

Ordering codes and packing units (lead spacing 15 mm Max. dimensions R RMS kHz 1600 450 1.0 6.0 1.5 6.0 2.2 6.5 3.3 7.5 4.7 8.5 ...

Page 8

B32633 Very high pulse (wound) Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R RMS kHz 630 300 22 6.5 33 7.0 47 ...

Page 9

Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R RMS kHz 2500 750 1.0 7.0 1.5 7.0 2.2 7.5 3.3 9.0 4.7 10.0 ...

Page 10

B32634 Very high pulse (wound) Ordering codes and packing units (lead spacing 27.5 mm Max. dimensions R RMS kHz 630 300 100 9.5 150 11.5 220 13.5 ...

Page 11

Technical data Operating temperature range Dissipation factor tan (upper limit values) Insulation resistance R ins rel. humidity 65% (minimum as-delivered values) DC test voltage Category voltage V C (continuous operation with ...

Page 12

B32632 ... B32634 Very high pulse (wound) Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed "k " represents the maximum permissible pulse characteristic of the waveform applied ...

Page 13

Impedance Z versus frequency f (typical values) Please read Cautions and warnings and Important notes at the end of this document. B32632 ... B32634 Very high pulse (wound) Page ...

Page 14

B32632 Very high pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 630 V DC/300 V AC 1600 V DC/450 V AC Please read Cautions ...

Page 15

Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 3000 V DC/750 V AC Please read Cautions and warnings and Important notes at the end of this ...

Page 16

B32633 Very high pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 630 V DC/300 V AC 1600 V DC/450 V AC Please read Cautions ...

Page 17

Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 2500 V DC/750 V AC Please read Cautions and warnings and Important notes at the end of this ...

Page 18

B32634 Very high pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 27.5 mm 630 V DC/300 V AC 1600 V DC/450 V AC Please read Cautions ...

Page 19

... Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba exposure to dry heat at 155 C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur ...

Page 20

... Please read Cautions and warnings and Important notes at the end of this document. 2.0 +0/ 0.5 mm from capacitor body or seating plane Heat-absorbing board, (1.5 0.5) mm thick, between capacitor body and liquid solder No visible damage 2% for MKT/MKP/MFP 5% for EMI suppression capacitors As specified in sectional specification Page ...

Page 21

... General notes on soldering Permissible heat exposure loads on film capacitors are primarily characterized by the upper cate- gory temperature T . Long exposure to temperatures above this type-related temperature limit max can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical characteristics. For short exposures (as in practical soldering processes) the heat load (and thus ...

Page 22

... MKT, MKP, MFP (coated/boxed) Even when suitable solvents are used, a reversible change of the electrical characteristics may occur in uncoated capacitors immediately after they are washed. Thus it is always recommended to dry the components (e. before they are subjected to subsequent electrical test- ing. Table A ...

Page 23

... Embedding of capacitors in finished assemblies In many applications, finished circuit assemblies are embedded in plastic resins. In this case, both chemical and thermal influences of the embedding ("potting") and curing processes must be taken into account. Our experience has shown that the following potting materials can be recommended: non-flexible epoxy resins with acid-anhydride hardeners ...

Page 24

... IEC 60068-2-6. EPCOS offers film capacitors specially designed for operation under more severe vibration regimes such as those found in automotive applications. Consult our catalog "Film Capacitors for Automotive Electronics". Please read Cautions and warnings and Important notes at the end of this document. Reference chapter " ...

Page 25

... Topic Safety information Soldering Do not exceed the specified time or temperature limits during soldering. Cleaning Use only suitable solvents for cleaning capacitors. 2 "Cleaning" Embedding of When embedding finished circuit assemblies in capacitors in plastic resins, chemical and thermal influences finished assemblies must be taken into account. ...

Page 26

B32632 ... B32634 Very high pulse (wound) Symbols and terms Symbol English Heat transfer coefficient Temperature coefficient of capacitance C A Capacitor surface area Humidity coefficient of capacitance C C Capacitance C Rated capacitance R C Absolute capacitance change C/C ...

Page 27

Symbol English I (Sinusoidal) alternating current, RMS root-mean-square value i Capacitance drift z k Pulse characteristic 0 L Series inductance S Failure rate Constant failure rate during useful 0 service life Failure rate, determined by tests test P Dissipated power ...

Page 28

B32632 ... B32634 Very high pulse (wound) Symbol English V Category voltage C V Category AC voltage C,RMS V Corona-discharge onset voltage CD V Charging voltage voltage DC V Fly-back capacitor voltage FB V Input voltage i ...

Page 29

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical ...

Related keywords