B84111F0000M030 EPCOS Inc, B84111F0000M030 Datasheet

Power Line Filters 2-LEITER EMV-FILTER 3A 250V

B84111F0000M030

Manufacturer Part Number
B84111F0000M030
Description
Power Line Filters 2-LEITER EMV-FILTER 3A 250V
Manufacturer
EPCOS Inc
Datasheet

Specifications of B84111F0000M030

Voltage Rating
250 V
Current Rating
3 A
Mounting Style
Screw
Product
Power Line Filters
Termination Style
Tab
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B84111F0000M030
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.
2−line filters
SIFI−F for normal insertion loss
250 V DC/AC, 50/60 Hz, 3 ... 36 A
Series/Type:
Date:
Version:
B84111F0000*
2008−08−07
07

Related parts for B84111F0000M030

B84111F0000M030 Summary of contents

Page 1

... SIFI−F for normal insertion loss 250 V DC/AC, 50/60 Hz, 3 ... 36 A Series/Type: B84111F0000* Date: 2008−08−07 Version: 07 © EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. ...

Page 2

... SIFI F for normal insertion loss Construction S 2 line filter S Metal case S Polyurethane potting ( Features S Optimized leakage current S Easy to install S Compact design S Cost optimized construction S ENEC10, UL und cUL approval c us Applications S Switched mode power supplies for industrial electronics telecom systems ...

Page 3

... SIFI F for normal insertion loss Typical circuit diagram of B84111F0000B* and B84111F0000G* LINE L N Technical data and measuring conditions of B84111F0000B* and B84111F0000G* Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current ...

Page 4

... SIFI F for normal insertion loss Typical circuit diagram of B84111F0000M* (for medical applications) Line L N Technical data and measuring conditions of B84111F0000M* (for medical applications) Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current ...

Page 5

... B84111F0000B116 4.8 B84111F0000B120 4.5 B84111F0000G125 < 1 300 1.6 B84111F0000G136 I Approx. R Ordering code leak typ weight µA g mΩ < B84111F0000M030 X < B84111F0000M060 X 90 12.5 B84111F0000M110 X 130 6.8 B84111F0000M116 X 130 4.8 B84111F0000M120 X 300 4.5 B84111F0000M125 X < 2 300 1.6 B84111F0000M136 X Page B84111F0000* Approvals ...

Page 6

... SIFI F for normal insertion loss Dimensional drawings B84111F0000*030 B84111F0000*060 B84111F0000*110 Please read and Cautions and warnings and Important notes at the end of this document. Marking all dimensions Page B84111F0000* Tab connector DIN 46244-A6.3-0.8 B84111-F0000-*-07-7659 ...

Page 7

... SIFI F for normal insertion loss Dimensional drawings B84111F0000*116 B84111F0000*120 Marking Please read and Cautions and warnings and Important notes at the end of this document. Tab connector DIN 46244-A6.3-0.8 all dimensions Page B84111F0000* B84111-F0000-*-07-7659 ...

Page 8

... SIFI F for normal insertion loss Dimensional drawings B84111F0000*125 B84111F0000*136 LINE Marking Please read and Cautions and warnings and Important notes at the end of this document. LOAD Page B84111F0000* B84111-F0000-*-07-7659 ...

Page 9

... SIFI F for normal insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84111F0000B030 100 B84111F0000B110 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 10

... SIFI F for normal insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84111F0000B120 100 B84111F0000G136 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 11

... SIFI F for normal insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84111F0000M030 100 B84111F0000M110 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 12

... SIFI F for normal insertion loss Insertion loss (typical values unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84111F0000M120 100 B84111F0000M136 100 Please read and Cautions and warnings and Important notes at the end of this document. ...

Page 13

... SIFI F for normal insertion loss Caution and warnings S Please note the advices in our data book “EMC Filters” (latest edition); attention should be paid to the chapter “General safety notes” shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance ...

Page 14

... SIFI F for normal insertion loss Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. ...

Related keywords