G6K-2F-Y-DC24 Omron, G6K-2F-Y-DC24 Datasheet

Low Signal Relays - PCB 3.2mm DPDT 24DC SMT Gullwing

G6K-2F-Y-DC24

Manufacturer Part Number
G6K-2F-Y-DC24
Description
Low Signal Relays - PCB 3.2mm DPDT 24DC SMT Gullwing
Manufacturer
Omron
Series
G6K2r
Datasheet

Specifications of G6K-2F-Y-DC24

Coil Type
Non-Latching
Coil Current
4.6 mA
Contact Form
2 Form C
Coil Voltage
24 VDC
Power Consumption
100 mW
Termination Style
Solder Pad
Maximum Switching Current
1 A
Contact Rating
0.3 A at 125 VAC, 1 A at 30 VDC
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6K2FY24DC OMRG6K2FY24DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6K-2F-Y-DC24V
Manufacturer:
OMRON
Quantity:
12 000
• Compact fourth generation design, offers excellent board
• Available in 2.54 and 3.2 mm coil-contact terminal spacing.
• “-Y” models meet 2.5 kV Bellcore surge requirements.
• Conforms to FCC Part 68.
• Terminal design based on Omron’s successful G6S relay.
• Available in PCB through-hole, SMT gullwing and SMT
• UL recognized / CSA certified.
• Available in single coil latching.
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5).
When ordering tape packing (surface mount versions), add “-TR” to the model number (e.g., G6K-2G-TR-DC5)
Specifications
■ Contact Data
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
Gullwing
Inside “L”
PCB through-hole
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note)
space savings.
“inside-L” terminals.
Low Signal Relay
G6K
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
Terminal
DPDT
Contact form
G6K-2F
G6K-2G
G6K-2P
Resistive load (cosφ=1)
0.3 A at 125 VAC
1 A at 30 VDC
Ag (Au clad)
1 A
125 VAC, 60 VDC
1 A
37.5 VA, 30W
10 μA at 10 mVDC
2.54 mm spacing
Non-latching
G6K-2F-Y
G6K-2G-Y
G6K-2P-Y
3.2 mm coil-contact
terminal spacing
Non-latching
Model
Low Signal Relay
G6KU-2F-Y
G6KU-2G-Y
G6KU-2P-Y
3.2 mm coil-contact
Single coil latching
terminal spacing
G6K
RC
67

Related parts for G6K-2F-Y-DC24

G6K-2F-Y-DC24 Summary of contents

Page 1

... To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5). Terminal Contact form Gullwing DPDT Inside “L” PCB through-hole When ordering tape packing (surface mount versions), add “-TR” to the model number (e.g., G6K-2G-TR-DC5) Specifications ■ Contact Data Load Rated load Contact material Max. carry current Max ...

Page 2

... Coil Data G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P) G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y) Rated voltage Rated current Coil resistance (VDC) (mA) (Ω) 3 33.0 91 4.5 23.2 194 5 21.1 237 6 17.6 341 9 11.3 795 12 9.1 ...

Page 3

... Operate voltage Release voltage Ambient temperature (°C) Electrical Service Life (with Must Operate and Must Release Voltage) (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y Sample: G6K-2G Number of Relays: 10 Test conditions resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/h ...

Page 4

... Contact Reliability Test (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y NO Sample: G6K-2G contact Number of Relays Test conditions resistive load at contact 10 mVDC with an operation rate Switching frequency: 7,200 operations/h 3 Operating frequency (x10 operations) Note 1: The test was conducted at an ambient temperature of 23°C. ...

Page 5

... G6K-2G Note: Each value has a tolerance of ±0.3 mm. G6K-2P Note: Each value has a tolerance of ±0.3 mm. Must Operate and Must Release Bounce Time Distribution (See note.) G6K-2G (F/P) , G6K-2G (F/P)-Y Must operate bounce time Must release bounce time Sample: G6K-2G Number of Relays: 50 Time (ms) ...

Page 6

... Note: Each value has a tolerance of ±0.3 mm. G6K-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2G-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6K 72 Low Signal Relay Mounting Dimensions (Top View) Terminal Arrangement/ Internal Connections Tolerance: ± ...

Page 7

... Tube packing Standard nomenclature Tape packing When ordering, add “TR” before the rated coil voltage (e.g., G6K-2G-TR-DC5). Note not part of the relay model number and will not be marked on the relay. (SMT versions, only) Relays in tube packing are arranged so that the orientation mark of each Relay is on the left side. ...

Page 8

... During automatic insertion of Relays, make sure to set the securing force of each claw to the following so that the Relays characteristics will be maintained. Direction A: 1.96 N Direction B: 4.90 N Direction C: 1.96 N G6K 74 Low Signal Relay (2) IRS Method (Mounting Solder: Lead-free) Upper surface of case (peak): 255˚C max. ...

Page 9

... Be sure to keep the proper distance between adjacent Relays as shown below to insure formation of good solder joints. G6K- min. G6K-2F 2.7 mm min. Two or more Relays may be mounted as closely as desired with the short sides of the Relays facing each other. G6K 75 Low Signal Relay ...

Page 10

... MEMO G6K 76 Low Signal Relay ...

Page 11

... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Low Signal Relay G6K ...

Page 12

... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 06/09 Cat. No. X301-E-1 G6K Low Signal Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...

Related keywords