G6A-234P-ST-US-DC24 Omron, G6A-234P-ST-US-DC24 Datasheet - Page 2

Low Signal Relays - PCB STANDARD DPDT 24VDC

G6A-234P-ST-US-DC24

Manufacturer Part Number
G6A-234P-ST-US-DC24
Description
Low Signal Relays - PCB STANDARD DPDT 24VDC
Manufacturer
Omron
Series
G6A2r

Specifications of G6A-234P-ST-US-DC24

Coil Type
Non-Latching
Coil Current
8.3 mA
Contact Form
2 Form C
Coil Voltage
24 VDC
Power Consumption
200 mW
Termination Style
Solder Pin
Contact Rating
0.30 A at 125 VAC, 1 A at 30 VDC
Contact Configuration
DPDT
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
24V
Current, Rating
0.3⁄1 AAC⁄ADC
Diameter, Mounting
0.04 in.
Dielectric Rating
1,000 VAC, 50⁄60 Hz for 1 minute between coil and contacts, 1,000 VAC, 50⁄60 Hz for 1 minute between contacts of different poles, 1,000 VAC, 50⁄60 Hz for 1 minute between contacts of same pole, 250 VAC, 50⁄60 Hz for 1 minute between set and reset coils
Dimensions
0.80 in. (Max.) L x 0.40 in. (Max.) W x 0.33 in. (Max.) H
Function
Sensitive
Material, Contact
AgPd (Au Clad)
Mounting Type
PCB
Number Of Pins
8
Power, Rating
125⁄60 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Termination
Solder
Voltage, Control
24 VDC
Voltage, Rating
125 VAC
Coil Resistance
2.88kohm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
DC24 G6A234PSTUS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6A-234P-ST-US-DC24V
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
G6A-234P-ST-US-DC24V
Manufacturer:
OMRON
Quantity:
2 477
Specifications
■ Contact Data
* 0.25A at 125VAC for latching models
Note: 1. P level:
■ Coil Data
Standard Non-latching DPDT (G6A-274P-ST-US)
Low-sensitivity Non-latching DPDT (G6A-274P-ST40-US)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
82
Type
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note)
3
4.5
5
6
9
12
24
48
3
4.5
5
6
9
12
24
48
voltage
voltage
Rated
(VDC)
Rated
(VDC)
2. G6A-4 pole versions are discontinued.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
This value was measured at a switching frequency of 60 operations/min and the criterion of contact resistance is 50 Ω. This value may
vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating con-
ditions.
Low Signal Relay
66.70
44.6
40
33.30
22.20
16.70
8.30
4.90
133.30
88.9
80
66.70
44.30
33.30
16.70
8.30
λ
60
current
current
Rated
Rated
(mA)
(mA)
= 0.1 x 10
–6
45
101
125
180
405
720
2,880
9,750
22.50
50.6
62.50
90
203
360
1,440
5,760
/operation
resistance
resistance
Coil
Coil
(Ω)
(Ω)
G6A
0.50 A at 125 VAC,
2 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
2 A
125 VA, 60 W
10 μA, 10 mVDC
0.07
0.16
0.20
0.29
0.63
1.10
4.50
13.70
0.03
0.065
0.08
0.11
0.27
0.52
2.10
7.50
Armature
Armature
OFF
OFF
Coil inductance
Coil inductance
(ref. value) (H)
(ref. value) (H)
Resistive load (p.f. = 1)
0.065
0.14
0.18
0.26
0.57
1.06
4.10
12.50
0.02
0.06
0.07
0.10
0.23
0.43
1.80
6.40
Armature
Armature
ON
ON
G6AK-274P-ST(40)-US, G6AK-474P-ST(40)-US
G6A-274P-ST(40)-US, G6A-474P-ST(40)-US
G6AU-274P-ST-US, G6AU-474P-ST-US
70% max.
70% max.
Pick-up
voltage
Pick-up
voltage
% of rated voltage
% of rated voltage
0.3 A* at 125 VAC,
1 A at 30 VDC
1 A
62.50 VA, 30 W
10% min.
10% min.
Dropout
Dropout
voltage
voltage
Inductive load (p.f. = 0.4)
200%
at 23°C
150%
at 23°C
(L/R = 7 ms)
Maximum
Maximum
voltage
voltage
Approx. 200
Approx. 235
Approx. 400
consumption
consumption
Power
Power
(mW)
(mW)

Related parts for G6A-234P-ST-US-DC24