G6S-2-DC12 Omron, G6S-2-DC12 Datasheet

Low Signal Relays - PCB DPDT PCB Terminal Fully Sealed

G6S-2-DC12

Manufacturer Part Number
G6S-2-DC12
Description
Low Signal Relays - PCB DPDT PCB Terminal Fully Sealed
Manufacturer
Omron
Series
G6Sr
Datasheets

Specifications of G6S-2-DC12

Coil Current
11.7 mA
Contact Form
2 Form C (DPDT)
Coil Voltage
12 V
Power Consumption
140 mW
Contact Carry Current
2 A
Termination Style
Solder Pin
Maximum Switching Current
2 A
Contact Rating
2 A
Contact Configuration
DPDT
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Coil Type
DC, Monostable
Current, Rating
0.5⁄2 AAC⁄ADC
Dielectric Rating
2000 VAC
Dimensions
0.583 in. L x 0.287 in. W x 0.362 in. Hin.
Function
General Purpose
Material, Contact
Ag (Au Clad)
Mounting Type
PCB
Number Of Pins
8
Power, Rating
62.5⁄60 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, RoHS
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-40 °C
Terminal Type
PCB through-hole
Termination
Through Hole
Voltage, Control
12 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6S2DC12BYOMR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6S-2-DC12
Manufacturer:
OMRON
Quantity:
6 373
Part Number:
G6S-2-DC12
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
G6S-2-DC12V
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
G6S-2-DC12V
Manufacturer:
OMRON
Quantity:
20 000
Company:
Part Number:
G6S-2-DC12V
Quantity:
13 656
Surface Mounting DPDT Relay
Ordering Information
Model Number Legend
1. Relay Function
2. Contact Form
3. Terminal Shape
G6S@-@@-@ @ VDC
Note: 1. When ordering, add the rated coil voltage to the model number.
DPDT
RoHS Compliant
Long terminals for ideal for soldering and mount-
ing reliability.
Space-saving inside-L terminal.
High dielectric strength between coil and contacts
(2,000 VAC), and between contacts of different
polarity (1,500 VAC).
High impulse withstand voltages between coil and
contacts, and between contacts of different polar-
ity (2,500 V, 2 × 10 µs: Bellcore requirements).
Low power consumption (140 mW).
Bifurcated crossbar contact (Au-clad) and Fully
sealed construction for high reliability.
Applicable to IRS.
High sealability after IRS.
Ultra-miniature at 15 × 7.5 × 9.4 mm (L × W × H).
Through-hole terminal is available
EN60950/EN41003 Supplementary Insulation-
certified type is available.
PCB Relay
None: Single-side stable
U:
K:
2:
None: PCB terminal
G:
F:
1
2. When ordering tape packing, add "-TR" to the model number.
Fully
sealed
Example: G6S-2F 12 VDC
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case.
Example: G6S-2F-TR 12 VDC
Single-winding latching
Double-winding latching
DPDT
Inside-L surface mounting terminal
Outside-L surface mounting terminal
2 3
4
Classification
PCB terminal
Surface mount-
ing terminal
5
Rated coil voltage
Tape packing
Inside-L
Outside-L
G6S-2
G6S-2G
G6S-2F
Single-side
stable
4. Approved Standards
5. Rated Coil Voltage
None: UL/CSA
Y:
3, 4.5, 5, 12, 24 VDC
G6SU-2
G6SU-2G
G6SU-2F
Single-winding
latching
EN60950/EN41003
G6SK-2
G6SK-2G
G6SK-2F
Double-winding
latching
G6S
G6S-2-Y
G6S-2G-Y
G6S-2F-Y
EN60950/EN41003
Single-side stable
1

Related parts for G6S-2-DC12

G6S-2-DC12 Summary of contents

Page 1

... Note: 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F 12 VDC Rated coil voltage 2. When ordering tape packing, add "-TR" to the model number. Example: G6S-2F-TR 12 VDC Tape packing Be sure since "-TR" is not part of the relay model number not marked on the relay case. Model Number Legend ...

Page 2

... The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G) Rated voltage 3 VDC Rated current 66 ...

Page 3

... G6S Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y) Rated voltage 5 VDC Rated current 40 mA 125 Ω Coil resistance Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 170% of rated voltage at 23°C Power consumption Approx. 200 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° ...

Page 4

... Approved Standards ■ UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR31928) Model G6S-2, G6S-2F, G6S-2G DPDT G6SU2, G6SK-2, G6SU-2F, G6SU2G, G6SK-2F, G6SK-2G EN60950/EN41003 Model G6S-2-Y, G6S-2G-Y, G6S-2F-Y DPDT 4 Contact form Coil ratings 1 VDC 1 VDC Contact form Isolation category Supplementary Isolation G6S ...

Page 5

... Time (s) Ambient Temperature vs. Maximum Coil Voltage Single-side Stable 12 VDC max. 24 VDC (G6S-Y, 12 VDC max.) 24 VDC (G6S-Y) Ambient temperature (°C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Single-winding Latching Double-winding Latching G6SU 12 VDC max ...

Page 6

... G6S Dimensions Note: All units are in millimeters unless otherwise indicated. Single-side Stable G6S-2, G6S-2-Y Tolerance: ±0.3 G6S-2F, G6S-2F-Y Tolerance: ±0.3 G6S-2G, G6S-2G-Y Tolerance: ±0.3 6 Footprint Terminal Arrangement/ (Bottom View) Internal Connections (Bottom View) Tolerance: ±0.1 Eight, 1-dia. holes Orientation mark Footprint ...

Page 7

... View) Tolerance: ±0.1 Eight, 1-dia. holes Footprint (Top View) Tolerance: ±0.1 7.3+0.2 Footprint 7.3+0.2 (Top View) Tolerance: ±0.1 G6S Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) ...

Page 8

... Footprint (Bottom View) Tolerance: ±0.1 Ten, 1-dia. holes Footprint (Top View) Tolerance: ±0.1 Footprint 7.3+0.2 (Top View) Tolerance: ±0.1 G6S Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) ...

Page 9

... Use a DC power supply with 5% or less ripple factor to operate the coil. Do not use the G6S where subject to strong external magnetic fields. Do not use the G6S where subject to magnetic particles or exces- sive amounts of dust. Do not reverse the polarity of the coil (+, −). Latching types are delivered in the reset position. We recommend that a reset voltage be applied in advance to start operation ...

Page 10

... G6S 10 G6S ...

Page 11

... G6S G6S 11 ...

Page 12

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K093-E1-05 In the interest of product improvement, specifications are subject to change without notice. OMRON RELAY & DEVICES Corporation C & C Power Relay Division Marketing Department 1110, Sugi, Yamaga-city, Kumamoto-Pref., 861-0596 Japan Tel: (81)968-44-4160/Fax: (81)968-44-4107 G6S Printed in Japan 0306-0.4M (0595) (A) ...