G6S-2G-DC5 Omron, G6S-2G-DC5 Datasheet - Page 2

Low Signal Relays - PCB J LEADS DPDT 5VDC

G6S-2G-DC5

Manufacturer Part Number
G6S-2G-DC5
Description
Low Signal Relays - PCB J LEADS DPDT 5VDC
Manufacturer
Omron
Series
G6Sr
Datasheet

Specifications of G6S-2G-DC5

Contact Form
2 Form C
Coil Voltage
5 VDC
Coil Current
28.1 mA
Coil Type
Non-Latching
Power Consumption
140 mW
Termination Style
Solder Pad
Maximum Switching Current
2 A
Contact Rating
0.5 A at 125 VAC, 2 A at 30 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6S2GDC5BYOMR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6S-2G-DC5V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G6S-2G-DC5V
Quantity:
180
Specification
■ Contact Data
Note: P level:
■ Coil Data
G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2)
G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2)
G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2)
G6S - European Version, Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
96
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
3
4.5
5
12
24
3
4.5
5
12
24
3
4.5
5
12
24
5
12
24
voltage
voltage
voltage
voltage
Rated
(VDC)
Rated
(VDC)
Rated
(VDC)
Rated
(VDC)
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the operating environment. Always double-check relay suitability under actual operating conditions.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. Pick-up voltage will vary with temperature.
4. The maximum voltage is the highest voltage that can be imposed on the relay coil.
λ
Low Signal Relay
46.7
31.0
28.1
11.7
8.3
33.3
22.2
20.0
8.3
6.3
66.6
44.4
40
16.7
12.5
40.0
16.7
9.6
60
current
current
current
current
= 0.1 x 10
Rated
Rated
Rated
Rated
(mA)
(mA)
(mA)
(mA)
-6
/operation
64.3
145
178
1,028
2,880
90
203
250
1,440
3,840
45
101
125
720
1,920
125
720
2,504
resistance
resistance
resistance
resistance
Coil
Coil
Coil
Coil
(Ω)
(Ω)
(Ω)
(Ω)
G6S
0.5 A at 125 VAC
2 A at 30 VDC
Ag (Au clad)
2 A
250 VAC, 220 VDC
2 A
62.5 VA, 60 W
10 μA, 10 mVDC
75% max.
0.108
0.27
0.36
2.12
5.80
0.045
0.12
0.14
0.60
1.98
75% max.
Armature
Armature OFF
OFF
Pick-up
voltage
Pick-up
voltage
Coil Inductance (H)
Set
(ref. value)
0.035
0.074
0.088
0.41
1.23
Armature
Coil Inductance (H)
ON
0.069
0.14
0.18
1.14
3.79
(ref. value)
10% max.
10% max.
% of rated voltage
Armature ON
% of rated voltage
Dropout
Dropout
voltage
voltage
0.032
0.082
0.098
0.46
1.34
Armature
OFF
Reset
75% max.
170% max.@ 23°C
200% max.@ 23°C
170% max.@ 23°C
0.045
0.14
0.16
0.54
2.23
Resistive load (cos φ = 1)
Armature
Set pick-up
voltage
ON
Maximum
Maximum
% of rated voltage
voltage
voltage
75% max.
pick-up
voltage
% of rated voltage
75% max.
Set
Reset pick-up
voltage
Approx. 200
Approx. 230
Approx. 140
Approx. 200
75% max.
pick-up
voltage
Reset
Power consumption (mW)
Power consumption (mW)
Maximum volt-
180% max.
@ 23°C
170% max.
@ 23°C
140% max.
@ 23°C
Maximum
age
voltage
Approx. 100
Approx. 150
Approx. 200
Approx. 300
consumption
consumption
Power
Power
(mW)
(mW)

Related parts for G6S-2G-DC5