A-12W-K Fujitsu, A-12W-K Datasheet - Page 3

Low Signal Relays - PCB Mini Signal 12VDC

A-12W-K

Manufacturer Part Number
A-12W-K
Description
Low Signal Relays - PCB Mini Signal 12VDC
Manufacturer
Fujitsu
Datasheets

Specifications of A-12W-K

Contact Form
2 Form C (DPDT)
Coil Voltage
12 VDC
Coil Type
Non-Latching
Power Consumption
140 mW
Termination Style
PCB Pins
Maximum Switching Current
2 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A-12W-K
Manufacturer:
ATMEL
Quantity:
3 227
*
n INSULATION
n SPECIFICATIONS
Contact
Coil
Time Value
Life
Other
n SAFETY STANDARD AND FILE NUMBERS
1
Item
Resistance (initial)
Dielectric
Strength
Surge Voltage
Type
UL
CSA
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load
before production since reference values may vary according to switching frequencies, environmental conditions and
expected reliability levels.
Compliance
UL 478, UL 508
E 45026
C22.2 No. 14
LR 35579
Arrangement
Material
Resistance (initial)
Rating (resistive)
Maximum Carrying Current
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
Minimum Switching Load*
Capacitance
Nominal Power (at 20°C)
Operate Power (at 20°C)
Operating Temperature
Operate (at nominal voltage)
Release (at nominal voltage)
Mechanical
Electrical
Vibration Misoperation
Resistance Endurance
Shock Misoperation
Resistance Endurance
Weight
open contacts
coil and contacts
adjacent contacts
Item
1
2 form C (DPDT)
Gold overlay silver alloy
Maximum 50 mΩ (at 1 A 6 VDC)
0.5 A 125 VAC or 1 A 30 VDC
2 A
62.5 AV/30 W
125VAC, 110VDC
2 A
0.01 mA 10 mVDC
Approximately 0.5 pF (between open contacts, adjacent contacts)
Approximately 1.0 pF (between coil and contacts)
140 to 300 mW 100 to 150 mW 200 to 300 mW
80 to 170 W 60 to 85 mW
–40°C to +85°C (no frost) (refer to the CHARACTERISTIC DATA)
Maximum 6 ms Maximum 6 ms (set)
Maximum 4 ms Maximum 6 ms (reset)
1 × 10
2 × 10
10 to 55 Hz (double amplitude of 3.3 mm)
10 to 55 Hz (double amplitude of 5.0 mm)
500 m/s
1,000 m/s
Approximately 1.2 g
Minimum 1,000 MΩ (500VDC)
1,000 VAC 1 min.
1,000 VAC 1 min.
1500V (coil-contact) (10/160 µs standard wave)
Standard Type
A-( ) W-K
Contact rating
Flammability: UL 94-V0 (plastics)
0.5A, 125VAC (General use)
2A, 30VDC (resistive)
0.3A, 110VDC (resistive)
8
5
ops. minimum 1 × 10
ops. min. (0.5 A 125 VAC), 5 × 10
2
(11 ±1 ms)
2
( 6 ±1 ms)
Single Winding Latching Type
AL-( ) W-K
7
ops. minimum
5
ops. min. (1 A 30 VDC)
Double Winding Latching Type
150 to 170 mW
A SERIES
AL-D ( ) W-K
3

Related parts for A-12W-K