CPD500-4530G POWER ONE, CPD500-4530G Datasheet - Page 9

DC/DC Converters & Regulators 36-75Vin 500W 5V40A 3.3V50A/12V8A/-12V3A

CPD500-4530G

Manufacturer Part Number
CPD500-4530G
Description
DC/DC Converters & Regulators 36-75Vin 500W 5V40A 3.3V50A/12V8A/-12V3A
Manufacturer
POWER ONE
Datasheet

Specifications of CPD500-4530G

Output Power
500 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
40 A
Output Voltage (channel 2)
3.3 V
Output Current (channel 2)
50 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
8 A
Package / Case Size
162.5 mm x 100 mm x 40.6 mm
Output Voltage
5 V to 12 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Hold-up Time of CPD Models
For extended hold-up time of CPD models, use external
output capacitors or decoupling diodes and input capacitors
of adequate size.
Formula for additional external input capacitor:
whereas:
Redundant Operation and Hot Swap
Due to the integrated ORing FETs/diodes, the converters
are designed to be operated in redundant systems.
Hot swap is also possible, but the output voltages of each
bus may deviate dynamically by 5% during the plug-in /
plug-out operation.
Output Characteristic and Protection
All outputs are fully protected against continuous open-
circuit (no load) and continuous short-circuit conditions.
All outputs of CPx200/250 models have a constant current
limitation with a rectangular characteristic; see figure 3. In
addition, the total power from outputs Vo1, Vo2, and Vo3 is
limited to P
between these outputs. Output Vo4 is disabled in the case
of overtemperature generated by overcurrent.
In CPA500/550 and CPD500 models, the total power of all
four outputs is limited to P
Fig. 3
Typical output characteristic V
BCD20005-G Rev. AF, 18-Aug-10
C
Note: After V
voltage for the time t
after t
Note: We recommend connecting some capacitors parallel to
the bus to limit voltage deviations during hot swapping and
during switch-on / switch-off of the input voltage of one of the
parallel-connected converters.
i ext
C
P
h
t
t
V
V
0.95
h total
h
1.0
0.5
o
i min
ti
V
i ext
o
0
= –––––––––––––––––––––
h
/V
, the output voltage might be affected.
2 • P
o nom
= external input capacitance [mF]
= output power [W]
= efficiency [%]
= total hold-up time [ms]
= hold-up time [ms]
= minimum input voltage [V]
= threshold level [V]
o max
o
• (V
, resulting in a free choice of load distribution
i
• (t
was removed, the outputs maintain their
ti
h total
2
I
o nom
– V
h
. Even if V
®
– t
i min
o max
h
) • 100
2
)
.
o
200 – 550 Watt CompactPCI
versus I
i
comes back during t
I
o max
o
I
o L
05186b
h
, but
Page 9 of 19
I
o
In all models, all outputs are monitored for an overvoltage
condition. If an overvoltage of 120 – 130% is dedected, the
converter is permanently disabled. To reset, the input
voltage must be removed for 10 – 20 seconds.
Thermal Considerations and Protection
If a converter is mounted in the upright position with airflow
as specified in the general conditions of the tables 4 and 5,
allowing unrestricted forced-air cooling, and is operated at
its nominal input voltage and power at maximum ambient
temperature T
the measurement point of the case temperature T
Mechanical Data) will approach after an initial warm-up
phase the indicated maximum value of T
However, the relationship between T
heavily on the operating conditions and the system
integration. The thermal conditions are significantly
influenced by the input voltage, the output current, the
airflow, and the temperature of the adjacent elements and
surfaces. T
value only.
Fig. 4a
Output power versus temperature T
CPA200)
Fig. 4b
Output power versus temperature T
Note: The models CPA500/550 with version
approx. 60 s to recover.
1.0
0.6
0.5
1.0
0.5
P
P
0
0
o
o
T
T
/P
/P
A min
A min
o nom
o nom
Convection cooling
in upright position
®
Convection cooling
in upright position
A max
AC-DC and DC-DC Converters
A max
CPA, CPD Series Data Sheet
20
is therefore, contrary to T
(see Temperatures), the temperature at
30
30
05190b
JM011
40
40
A
A
200 LFM = 1 m/s
250 LFM = 1.25 m/s
at V
at V
50
50
A
i nom
i nom
www.power-one.com
C max
and T
70
70
C max
(CPD/
(CPD/CPA250)
400 LFM
= 2 m/s
, an indicative
V110 need
C
(105 °C) .
90 °C
90 °C
depends
C
(see