SDP4-24-100LT SOLA HEVI DUTY, SDP4-24-100LT Datasheet - Page 3

Linear & Switching Power Supplies 24-28VDC 4.2V Output

SDP4-24-100LT

Manufacturer Part Number
SDP4-24-100LT
Description
Linear & Switching Power Supplies 24-28VDC 4.2V Output
Manufacturer
SOLA HEVI DUTY
Type
Industrialr
Datasheets

Specifications of SDP4-24-100LT

Product
Switching
Brand/series
SDP Series
Configuration
Enclosed
Mounting Type
DIN Rail
Number Of Outputs
1
Operation
Switching
Output
24 to 28 VDC @ 3.8 A
Power, Output
100 W
Primary Type
AC-DC
Voltage, Input
85 to 264/210 to 375 VAC/VDC
Voltage, Output
24 to 28 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SDP™ Series Specifications (Other Voltages)
Notes:
120
Input Voltage
Input Frequency
Input Current
External Fusing
Hold-Up Time
Efficiency
Losses
Output Voltage
Voltage Regulation
Ripple/Noise
Overvoltage Protection (OVP)
Output Noise Suppression
Rated Continuous Loading
Overload Behavior
Protection
Power Back Immunity
Status Indicators
Case & Mounting
(H x W x D) (in/mm)
Weight - lbs (kg)
Mounting Orientation
Ventilation/Cooling
Connection
Temperature
MTBF
Humidity
Electromagnetic Emissions
(EME)
Electromagnetic Immunity
(EMI)
Safe Low Voltage
Protection Class/Voltage
Warranty
CB Scheme, EN60950, UL60079-15 (Class 1, Zone 2 Hazardous Locations, Temp Class T3), UL508 Listed, cULus, UL 60950, cURus,
CE (LVD 73/23 & 93/68/EEC), (EMC 89/336 & 93/68/EEC). EN61000-3-2, NEC Class 2 power supply acc. To NFPA 70 art. 725-41 (a)(2).
4
1. Not UL listed for DC input.
2. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
3. Not to exceed 30 watts total.
•Free space for cooling
•Connector size range
Description
2
1
7.5 W typ.
5 - 5.5 Vdc (5 - 6 min adj.)
l
out
= 5A @ V
SDP 5-5-100T
> 6.7 Vdc
Storage: -25°C...+85°C Operation: -10°...+60°C full power with linear derating to half power from 60°C to 70°C.
10 V
Input: screw terminals, connector size range: 20-12 AWG (1.5 - 6 mm
contact Technical Services at (800) 377-4384 with any questions.
out
= 5.1V
EN61000-6-2 (Includes EN61000-6-1) (EN55024) Criterion A: no degradation of performance
Continuous operation at overload/short-circuit: up to 1.5 x Nominal Current Continuous
0.33 A @196 Vac
0.6 A @ 102 Vac;
Power Supplies
Molded plastic housing using UL 94 approved flameproof material rating 94V-2.
> 80% typ.
Unit is continuously protected against short-circuit, overload and open-circuit.
Visit our website at www.solahd.com or
Standard: Vertical; Optional: Horizontal or On Top (Contact Technical Services).
> 500,000 hours according to Telcordia/Bellcore Document SR-332, Issue 1.
Normal convection, no fan required; Above/below: 25 mm recommended.
EN61000-6-3 (Includes EN61000-6-4) Class B (EN 55022) incl. Annex A
8.1 W typ.
12 Vdc (9.9 - 12.1 min adj. )
Not required. Unit provides internal fuse (T3A, not accessible)
Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.
Up to 90% RH, noncondensing; IEC 68-2-2, 68-2-3
SDP 2-12-100T
2.5A @12 Vdc
3A @ 10 Vdc
(Convection cooling, no forced air required).
> 18 Vdc
Dimensions
Installation
IP20 (IEC529), Protection Class 1 (IEC536)
Radiated EMI values below EN61000-6-2
General
Output
Safety
Input
2.95 x 1.77 x 3.58 (75 x 45 x 91)
Green LED on, when V
< 2% Dynamic; < 0.5% Static
85-264 Vac, 90-375 Vdc
SELV (acc. EN60950)
Catalog Number
0.5 lbs (.23 kg)
< 50 mVpp
47-63 Hz
> 25 ms
3 years
22 V
15 Vdc (11.9 - 15.1 min adj.)
out
1.0 A @ 102 Vac;
0.6 A @ 196 Vac
SDP 3-15-100T
4.2A @ 12 Vdc
3.4A @ 15 Vdc
“OK”.
> 86% typ.
> 20 Vdc
2
) for solid or stranded conductors.
< 8.1 W typ.
48 Vdc (48 - 56 min adj.)
3
Up to 1.05A @ 48 V
<1.0 A @ 100 Vac;
<0.6 A @ 196 Vac
SDP 1-48-100T
0.9A @ 56 V
> 90% typ.
> 56 Vdc
80 V